Purpose

Provide additional information for message ID: DISK-8000-CY

Details

Type: Hardware Fault

fault.io.scsi.disk.csum-zfs.sticky

Severity: Critical

Description

The message ID: DISK-8000-CY indicates that there have been non-recovered ZFS checksum errors on this disk.

Automated Response

The device may be offlined or degraded. A hot-spare disk may have been activated.

Impact

It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.

Suggested Action for System Administrator

The administrator should arrange to have the faulty disk replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)