Solution Type  Predictive Self-Healing Sure

Solution  1427603.1 :   DISK-8000-9H - There have been excessive recovered medium read errors on this disk  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC T7-4
  •  
  • SPARC T8-2
  •  
  • SPARC T7-2
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




Applies to:

Sun Microsystems > Storage - Disk
Sun Microsystems > Servers
SPARC T7-1
SPARC T7-2
SPARC T7-4
All Platforms

Purpose

Provide additional information for message ID: DISK-8000-9H

Details

Type: Hardware Fault

fault.io.scsi.disk.merr.read_recovered

Severity: Major

Description

The message ID: DISK-8000-9H indicates that there have been excessive recovered medium read errors on this disk.

Automated Response

The device may be offlined or degraded. A hot-spare disk may have been activated.

Impact

If a hot spare is available it will be brought online and during this time I/O could be impacted. If a hot spare isn't available then I/O could be lost and data corruption is possible.

Suggested Action for System Administrator

The administrator should arrange to have the faulty disk replaced.

Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required


PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)