Asset ID: |
1-79-1417465.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1417465.1
:
PCIEX-8000-XE - A problem was detected in the PCI Express hotplug controller
Related Items |
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Sun Microsystems > Boards
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
Information in this document applies to any platform.
Purpose
Provide additional information for message ID: PCIEX-8000-XE - A problem was detected in the PCI Express hotplug controller
Details
Type
- Hardware Fault
- fault.io.pciex.hp-powerfault
Severity
- Major
Description
-
A problem was detected in the PCI Express hotplug controller
Automated Response
-
One or more device instances may be disabled
Impact
-
Loss of services provided by the device instances associated with this fault
Suggested Action for System Administrator
-
The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the PCI Express link may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
NOTE: This Message ID will not result in a service request being automatically opened via ASR
Attachments
This solution has no attachment