Asset ID: |
1-79-1387771.1 |
Update Date: | 2017-11-02 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1387771.1
:
Troubleshooting inability to see a pre-existing RAID volume on T3, T4, T5, T7 & T8 systems
Related Items |
- SPARC T7-4
- SPARC T5-8
- Netra SPARC T4-1 Server
- SPARC T8-1
- SPARC T8-2
- SPARC T7-2
- SPARC T4-1
- SPARC T3-2
- SPARC T8-4
- SPARC T3-1
- SPARC T5-2
- SPARC T5-4
- SPARC T5-1B
- SPARC T7-1
- Netra T3-1
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T3
- _Old GCS Categories>Sun Microsystems>Servers>CMT Servers
|
In this Document
Applies to:
SPARC T3-1 - Version Not Applicable and later
SPARC T5-2 - Version All Versions and later
SPARC T5-4 - Version All Versions and later
SPARC T5-8 - Version All Versions and later
SPARC T5-1B - Version All Versions and later
Information in this document applies to any platform.
Purpose
When replacing a system board or REM card on T3, T4, T5, T7, T8 systems, certain procedures will need to be followed if on board hardware raid volumes are configured.
Details
When replacing a system board or REM card certain procedures will need to be followed if on board hardware raid volumes are configured. Failure to do so would result in the volumes not being seen after component is replaced. The volumes will need to be reactivated. This needs to be done for each on board controller path or REM.
T3-1 T4-1
Controller 0 /pci@400/pci@1/pci@0/pci@4/scsi@0/
Controller 1 /pci@400/pci@2/pci@0/pci@4/scsi@0/
Two controllers both on board and imbedded in system board. Both paths would need to be selected individually and inactive volumes activated if previously configured
Netra T3-1 & 4-1
Controller 0 /pci@400/pci@2/pci@0/pci@4/scsi@0/
One controller imbedded in system board so only the one controller needs to be selected and inactive volumes activated if previously configured
T3-2 T4-2
/pci@400/pci@2/pci@0/pci@e/scsi@0
One controller imbedded in system board so only the one controller needs to be selected and inactive volumes activated if previously configured
Netra T4-2
Controller 0 /pci@400/pci@2/pci@0/pci@e/scsi@0/
Controller 1 /pci@500/pci@1/pci@0/pci@4/scsi@0/
Two controllers both on board and imbedded in system board. Both paths would need to be selected individually and inactive volumes activated if previously configured
T3-4 T4-4 (4 proc)
Controller 0 /pci@400/pci@1/pci@0/pci@0/LSI,sas@0/
Controller 1 /pci@700/pci@1/pci@0/pci@0/LSI,sas@0/
Each REM is an individual card so only volumes on replaced card’s path will need to be reactivated if previously configured
T3-4 T4-4 (2 proc)
Controller 0 /pci@400/pci@1/pci@0/pci@0/LSI,sas@0/
Controller 1 /pci@500/pci@1/pci@0/pci@0/LSI,sas@0/
Each REM is an individual card so only volumes on replaced card’s path will need to be reactivated if previously configured
T3-1b
Controller 0 /pci@400/pci@1/pci@0/pci@2/LSILogic,sas@0/
T4-1b
Controller 0 /pci@400/pci@1/pci@0/pci@c/LSI,sas@0
T5-2 1S
Controller 0 /pci@300/pci@1/pci@0/pci@2/scsi@0 sas0
Controller 1 /pci@340/pci@1/pci@0/pci@2/scsi@0 sas1
T5-2
Controller 0 /pci@300/pci@1/pci@0/pci@2/scsi@0 sas0
Controller 1 /pci@3c0/pci@1/pci@0/pci@2/scsi@0 sas1
T5-4
Controller 0 /pci@300/pci@1/pci@0/pci@4/pci@0/pci@c/scsi@0 sas0
Controller 1 /pci@4c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0 sas1
T5-8
Controller 0 /pci@300/pci@1/pci@0/pci@4/pci@0/pci@c/scsi@0 sas0
Controller 1 /pci@6c0/pci@1/pci@0/pci@c/pci@0/pci@c/scsi@0 sas1
T5-1B
/pci@300/pci@1/pci@0/pci@4/LSILogic,sas@0
One controller imbedded in system board so only the one controller needs to be selected and inactive volumes activated if previously configured
T7-1
Controller 0 /pci@301/pci@2/scsi@0
T7-2
Controller 0 /pci@301/pci@1/scsi@0
Controller 1 /pci@303/pci@1/scsi@0
T7-4
Controller 0 /pci@300/pci@2/scsi@0
Controller 1 /pci@302/pci@1/scsi@0
T8-1
Controller 0 /pci@301/pci@2/scsi@0
T8-2
Controller 0 /pci@301/pci@1/scsi@0
Controller 1 /pci@303/pci@1/scsi@0
T8-4
Controller 0 /pci@300/pci@2/scsi@0
Controller 1 /pci@302/pci@1/scsi@0
=======================
Disable auto-boot in OBP and enter the OBP environment after you have
powered the server back on.
{0} ok show-disks
a) /pci@400/pci@2/pci@0/pci@f/pci@0/usb@0,2/hub@2/hub@3/storage@2/disk
b) /pci@400/pci@2/pci@0/pci@4/scsi@0/disk
c) /pci@400/pci@1/pci@0/pci@4/scsi@0/disk
d) /iscsi-hba/disk
q) NO SELECTION
Enter Selection, q to quit: q
{0} ok setenv fcode-debug? true
{0} ok select /pci@400/pci@2/pci@0/pci@4/scsi@0 <---path to imbedded controller or REM from list above
{0} ok show-volumes
For every RAID volume that is listed as inactive, enter the following command to activate those volumes:
{0} ok 0 activate-volume <------ as an example activating volume 0
where the inactive volume is the name of the RAID volume that you are activating, for example 0 or 1
Once complete, unselect the controller and restore fcode-debug? to the false setting
{0} ok unselect-dev
{0} ok setenv fcode-debug? false
{0} ok reset-all
Attachments