Asset ID: |
1-79-1386243.1 |
Update Date: | 2017-10-18 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1386243.1
:
Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 Server ( Serengeti/Amazon ) system: Cheat Sheet
Related Items |
- Sun Fire 4810 Server
- Sun Fire 3800 Server
- Sun Fire E6900 Server
- Sun Fire 6800 Server
- Sun Fire 4800 Server
- Sun Fire E4900 Server
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Exx00
- _Old GCS Categories>Sun Microsystems>Servers>Midrange V and Netra Servers
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: migrated http://panacea.uk.oracle.com/twiki/bin/view/Products/SerengetiCheatSheet
Applies to:
Sun Fire E6900 Server - Version Not Applicable and later
Sun Fire 4800 Server - Version Not Applicable and later
Sun Fire 4810 Server - Version Not Applicable and later
Sun Fire 6800 Server - Version Not Applicable and later
Sun Fire E4900 Server - Version Not Applicable and later
Information in this document applies to any platform.
Purpose
Serengeti Product Line Cheat Sheet
Details
Data Collection
Collect explorer -w default,scextended,fru. See Document 1019066.1 for details.
When Explorer is not available, please manually collect the data specified in Document 1003529.1.
3800 Front |
3800 Rear |
4800/4900 Front |
4800/4900 Rear |
4810 Front |
6800/6900 Front |
6800/6900 Rear |
Commonly Used SC & LOM Commands
See the Command Reference Guide for full details
setdefaults |
Sets the configuration back to default values |
setfailover |
Changes SC failover status (force switches Main SC control). |
setkeyswitch |
Change the keyswitch position. |
addboard / deleteboard |
Assigns / Un-assigns a board to a domain (DR) |
break |
send break to the Solaris console |
console |
connect to the Solaris console |
history |
show command history |
password |
set the SC (or LOM) access password |
poweron / poweroff |
power on system / components and start OBP |
poweron all |
poweron all system / components only |
reboot |
Reboots the System Controller |
reset |
reset the Solaris system |
resume |
Exits the domain shell & resumes access to the domain console. |
setchs / showchs |
set / show FRU Component Health Status (setchs available only in service mode <5.20.15) </td> |
setdate / showdate |
set / show the date and time for the system |
disablecomponent / enablecomponent |
add / remove a component from the blacklist |
flashupdate |
update firmware (scapp) |
help |
show help for a command or a list of commands |
showcomponent |
Show state of a component |
showenvironment |
Show environmental information |
showerrorbuffer |
Show the contents of the error buffer |
setupdomain |
Configures the domain |
setupplatform / showplatform |
Configures / Shows the platform configuration |
showboards |
Shows board information |
showlogs |
Show the error logs (-v option should be used). |
showsc |
Show SC version and uptime information |
testboard / testinterconnect |
Test a board or run interconnect test (service mode commands) |
Connecting to the SC from an admin workstation:
Use a serial port connection:
# tip hardwire
Use telnet (assumes SC net has been configured with setupnetwork):
# telnet SC-hostname or IP address
Use SSH:
admin-ws% ssh 6800-sc1
Enter Password: As setup Connected. HIT RETURN Note – At 5.18.0, you will be offered the option of connecting with a secure shell (ssh) only if you have an SC V2 in the IB/SSC. In this case only SSH will work not telnet
How to send a break if connected to the SC:
See Document 1017808.1 for details.
|
Navigating between shells
Click image to see knowledge article on topic. |
POST levels (Change using diag-level?)
init - (Default level) Only initialization code is
run, no testing.
quick - Few tests and few patters.
min - Quick sanity check.
max - All components tested with all tests and
patterns, except for memory & Ecache.
mem1 - More exhaustive DRAM and SRAM tests.
mem2 - mem1 with the addition of a DRAM.
How to Identify the Physical DIMM Size:
- Physical Size is equal to "DIMM Size" in prtdiag.
- prtfru_-x.out data in Explorer identifies the
DIMM size.
- sc>showboards -p memory identifies the DIMM size.
How to Identify the CPU Speed:
- sc>showboards -v -p cpu shows the CPU speed.
- prtdiag identifies the CPU speed..
- prtfru_-x.out data in Explorer identifies CPU
speed and the board type.
- showlogs AD Event messaging does NOT identify
the correct FRU pn for a SB.
|
System Indicators (LEDs)
Click on the pictures to be taken to the Sun Fire Servers LED Page
Power Supply Units (L-R: 3800, 4800/4900, 4810/6800/6900)
 |
DIMM Layout on Board
Click the picture to see an enlarged image. |
|
References
<NOTE:1003150.1> - Sun Fire[TM] 3800, 4800, 4810, 6800, E4900, and E6900: Navigating Between Shells on Sun Fire Mid-range Servers [Video]
<NOTE:1003529.1> - Procedure to manually collect System Controller (SC) level failure data on Sun Fire[TM] v1280, E2900, 3800, 4800, E4900, 6800, E6900, and Netra 1280, 1290 servers.
<NOTE:1017808.1> - send break does not always work on Sun Fire[TM] platform
<NOTE:1019066.1> - Sun Fire[TM] v1280, 3800, 4800, 4810, 6800, E2900, E4900, E6900 and Netra[TM] 1280, 2900 servers: How to collect scextended or 1280extended Explorer
Attachments
This solution has no attachment