Asset ID: |
1-79-1380033.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1380033.1
:
PCIEX-8000-V2 - PCIEX link bandwidth decrease
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC M8-8
- Oracle SuperCluster M7 Hardware
- SPARC M7-8
- SPARC T7-4
- SPARC T8-2
- Oracle SuperCluster M8 Hardware
- SPARC T7-2
- Solaris (SPARC)
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Sun Microsystems > Boards
Solaris (SPARC)
SPARC T8-1
SPARC T8-2
SPARC T8-4
Information in this document applies to any platform.
Purpose
Provide additional information for message ID: PCIEX-8000-V2 - PCIEX link bandwidth decrease
Details
Type
- Hardware Fault
- fault.io.pciex.bus-linkbw-down
Severity
- Major
Description
-
An unexpected decrease in PCIe (PCI Express) link bandwidth has been detected
Automated Response
- None
Impact
-
Potential performance degradation for the devices associated with this fault
Suggested Action for System Administrator
-
The recommended service action for this event is to schedule replacement of the affected component(s) at the earliest possible convenience. Although the PCIe link may be functioning, it is not intended nor recommended that the faulted component(s) remain in the system for a prolonged period of time.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
Attachments
This solution has no attachment