Sun Fire X4800 Server Firmware Details
Related Categories |
- PLA-Support>Sun Systems>x86>Server>SN-x64: SERVER 64bit
- _Old GCS Categories>Sun Microsystems>Servers>x64 Servers
|
Summary of X4800 Firmware Release Details.
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Panacea migration
Applies to:
Sun Fire X4800 Server - Version Not Applicable and later
Information in this document applies to any platform.
Purpose
Provides X4800 Firmware Release Details.
Details

Sun Fire X4800 Server Firmware 1.0
This release includes the following firmware:
Released version:
- ILOM version 3.0.9.11 (build number 55414) (Service Processor firmware) - ILOM 3.0.9.11 for Sun Fire X4800 Management Module (CMM)
- BIOS 23
- CPLD 7.6 and 5.6
- HPC FPGA 1.8
- Hostmon 1.2.1
- SIA 2.4.3.17
- SunVTS 7.0ps08
Sun Fire X4800 Server Firmware 1.0.1
This release includes the following firmware:
Released version:
- ILOM version 3.0.9.30 (build number 57897) (Service Processor firmware) - ILOM 3.0.9.30 for Sun Fire X4800 Management Module (CMM)
- BIOS 34
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.4
- NEM FPGA v15
- SIA 2.4.3.24
- SunVTS 7.0ps08
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.50.03-0807/BIOS 3.11.00
- Bugs fixed:
- BUG 15640865 - spdiag voltest failed in RQT
- BUG 15656466 - memstore value is NOT restored after reset SP
- BUG 15659914 - g5cpldflash.sh can brick CMOD if CPLD flash fails.
- BUG 15629623 - callisto/G5: disable LLEM by default
- BUG 15651159 - SP version 3.0.9.30 still showing version 3.0.9.11 in CLI and web GUI
- BUG 15651190 - FRU data has changed a lot after SP flashed to build 2010-24
- BUG 15599357- allow multiple host serial 'start /SP/console' sessions at same time
- BUG 15628500 - Pre-RQT unit had a /SYS/FM0 fault.chassis.device.fan.fail Fault Failure
- BUG 15656667 - CMOD stuck at u-boot flashing ILOM image in a loop
- BUG 15654409 - Single-sign-on is broken for JavaRConsole
- BUG 15654649 - JARs need to be re-signed for SW 1.0.1
- BUG 15631735 - implement the console history feature
- BUG 15631072 - BM /persist full cause DIMM FRUID not showing up
- BUG 15656091 - /SYS/SERVICE led is not turned On when /SYS/T_AMB > threshold
- BUG 15647987 - False fan missing faults reported once flash SP to build 2010-22
- BUG 15649550 - Fault restoration is unable to set BM service LED.
- BUG 15615159 - PSU power loss fault is not cleared when power cable is reconnected
- BUG 15632435 - BL SERVICE LED is not turned off when flash SP while /SYS/SERVICE LED is off
- BUG 15652459 - Junk code shows in event log "Update inventory starting at node X"
- BUG 15644791 - PSU ac low line isn't faulted by fault diagnostic.
- BUG 15648210 - False blade population fault reported on 4-socket after SP flash
- BUG 15648597 - spare_lane_failover fault policy
- BUG 15655517 - SP fails to retain DIMM misconfig faults after blade hotplug
- BUG 15621898 - FMA should not fault processor for parity errors in internal IOH datapaths
- BUG 15624885 - ILOM missed to report fault on the DIMMs used to replace faulty DIMMs
- BUG 15627196 - TEMP_FAULT is not On even though /SYS/T_AMB > upper non-recoverable high
- BUG 15651215 - Thermtrip neither logged nor diagnosed as a fault.
- BUG 15653334 - Mismatch of CPLD version needs to be faulted.
- BUG 15645413 - Sometimes failed to start host power
- BUG 15648214 - P1.B CPLD upgrade has remote I/O error
Sun Fire X4800 Server Firmware 1.1
This release includes the following firmware:
Released version:
- ILOM version 3.0.9.30.a (build number 59127) (Service Processor firmware) - ILOM 3.0.9.30.a for Sun Fire X4800 Management Module (CMM)
- BIOS 11014100
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v15
- NEM SAS Expander 5.3.3.4
- OHIA 2.4.3.26
- SunVTS 7.0ps09
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.50.03-0807/BIOS 3.11.00
- Bugs fixed:
- BUG 15660453 - Slot ID in SMBIOS Type 9 structures need to start at 0x1
- BUG 15659634 - fmtopo should enumerate DIMM and label them on per blade basis.
- BUG 15658731 - SPMI has wrong bit width
- BUG 15661229 - _CSD (C-State Dependencies) and _TSD (T-State Dependencies) return only 0
- BUG 15648927 - SLES11SP1 has problem to enter C3
- BUG 15664295 - G5:NEM hangs midplane i2c bus (One of the G5's has ipmitool fru list not showing the Ethernet NICs
- BUG 15529146 - Libra blades must provide memory ACPI objects
- BUG 15665292 - G5: BIOS should change the default setting of De-emphasis level to -3.5dB
- BUG 15653118 - g5: linux/xen: report extra cpus for cstate
- BUG 15630020 - libra: bios report extra cpus in DSDT when HT is disabled or 4 sockets are used
- BUG 15626156 - G5 with EMs may experience problems due to CR 6669984
- BUG 15622963 - Disabling "SRIOV and VTD" causes windows installation to hang
- BUG 15618637 - libra: EL 5.4: IB PEM does not work with 2S system
- BUG 15611063 - system loses memory on some CPU branches after a reboot (reboot due to fault injection)
- BUG 15669686 - G5: setting boot device to default hard drive does not put entry in SEL
- BUG 15669180 - g5: OEL: Niantic PEMs no driver
- BUG 15668616 - g5: RH v7 cpuscaling failed on the new kernel.
- BUG 15667539 - g5: clocktest fail
- BUG 15665294 - G5: BIOS should enable the 'Extended Synch' in all IOHs
- BUG 15606073 - Blue LED follows drive after "Prepare Removal" on slot
- BUG 15599536 - Niwot:MSM:Gui hung for excessive period of time after cable pull of 4 JBOD cascade config
- BUG 15599039 - EL 5.4 pciehp not work with Metis-E (Emulex/82571 dual port)
- BUG 15589478 - G5 Slot-Based MAC Address for onboard NICs
- BUG 15588940 - libra: EL 5.4 non xen kernel crash with 1T memory
- BUG 15587298 - G5(BQA):Cannot load RHEL5.3 if ACPI is disabled in the BIOS setup
Sun Fire X4800 Server Firmware 1.2
This release includes the following firmware:
Released version:
- ILOM version 3.0.14.17 (build number 62928) (Service Processor firmware) - ILOM 3.0.14.17 for Sun Fire X4800 Management Module (CMM)
- BIOS 11015600
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v16
- NEM SAS Expander 5.7.0.0 (requires separate manual update, and must update ILOM/BIOS first)
- SunVTS 7.0ps09
- PSU Firmware: -06 (requires separate manual sunservice access to update)
- Bugs fixed BIOS:
- BUG 15698583 - G5: ITP CE fault injection does not fault and disable dimm
- BUG 15693428 - ITP CE fault injection does not generate UE after more than 240 CEs injected within 72hrs
- BUG 15693282 - ITP injected UE doesn't disable DIMMs
- BUG 15695798 - 8S configuration should not check for CMOS setup option for "Hemisphere Mode"
- BUG 15685517 - Bios 52 does not handle DIMM SPD errors correctly
- BUG 15647046 - Write protect SPD data on Samsung DIMMs
- BUG 15684513 - 6 core 4 socket system had a CPU error
- BUG 15689584 - G5 sw 1.2 bl and cpu faulted on 4 socket systems
- BUG 15687503 - bios: ACPI methods incorrectly use mutex
- BUG 15646709 - G5 P2 unit had a Memory: BIOS: Configuration Error: MRC Branch error 0x08 in IST/SFT
- BUG 15660663 - MRC should issue SMBus Stop symbol before 1st transaction
- BUG 15684362 - G5 has wrong interleave settings in BIOS menu
- BUG 15675177 - Wrong taps for the longest diagonal links
- BUG 15648207 - enable patrol scrubbing in G5
- BUG 15660702 - Increase in memory latency when Patrol scrubbing is enabled
- BUG 15684512 - Need to update dram_ecc_per_rank_2 msg in SUNECC_HAndler_FAR (SMI handler)
- BUG 15665884 - ECCs are polled at a slower rate than what's displayed in the setup was missed.
- BUG 15681051 - Cstate _CSD should have domain id per core.
- BUG 15681321 - linux need SRAT table consistent with MADT
- BUG 15675227 - acpi error: method parse execution failed and namespace lookup failure,
- BUG 15672257 - Modified 'Coordination type' to HW_ALL in Package of _CSD Method
- BUG 15679729 - Add WHEA missed operations
- BUG 15681228 - RHEL 6.0 reports AER with Erie PEM
- BUG 15679528 - g5: smbios reports wrong KCS Base Address
- BUG 15677433 - SMBIOS records show incomplete brand name for some fields
- BUG 15676415 - G5M2 BIOS: need to disabled USB controller pci function
- BUG 15665686 - BIOS should not mask bit 22 "errtimeout' in Bbox error log message
- BUG 15673557 - Incorrect Message format for "MCA Register dump"
- BUG 15665685 - Mbox error scraping doesn't report UEs detected by Patrol Scrubber
- BUG 15665884 - ECCs are polled at a slower rate than what's displayed in the setup
- BUG 15665687 - Implement "Early uncore reporting", leveraged code from Callisto CR#6963668
- BUG 15644492 - RHEL 6 Beta reports disabling IRQ 16
- BUG 15654998 - 2.6.32.y based RHEL6/SLES11SP1: report ACPI error
- BUG 15646489 - APEI table is invalid
- BUG 15675994 - G5: RHEL 6.0 beta shows a lot of AER errors with Niwot in 'dmesg'
- BUG 15595416 - Need to remove some unused ASL code in DSDT of legacy ACPI hotplug
- BUG 15661890 - BIOS PIRQ table has wrong slot information
- BUG 15672572 - Need to remove some unused ASL hotplug code in ACPI DSDT
- BUG 15666218 - Update Serial Redirection eModule to Label: .00.03_SREDIR_03.01_B10
- BUG 15666216 - Add Poison Forwarding Mode option in Expert Mode of BIOS setup menu
- BUG 15669356 - Setup menu option "Event Log Configuration" should be removed
- BUG 15670589 - Setup cleanup
- BUG 15669273 - Updated, P2 bios/menus Some entries are still changeable with User
- BUG 15669264 - MAC addresses displayed in BIOS setup and in SP do not match
- BUG 15659634 - fmtopo should enumerate DIMM and label them on per blade basis
- BUG 15667662 - Create SMBIOS on board device extended information type
- BUG 15671063 - Create SMBIOS type 144 (Extended Memory Array)
- BUG 15676455 - Modified SMBIOS Type 9, 19 and 41
- BUG 15669930 - Reduce duplicated "No bootable media" logs
- BUG 15673550 - BIOS is confusing core and uncore MCA banks in MCA dump IPMI messages
- BUG 15608344 - There is no SEL entry for disabled QPI links
- BUG 15636474 - Disable USB PCI function
- BUG 15669222 - Manipulating USB functionality caused various strange results with keyboard
- Bugs fixed in ILOM:
- BUG 15680146 - G5: spdiag rtc Set Date and Time in 12 hour mode has not yet implemented
- BUG 15673036 - hostdiags info hangs with Ilom 59127, Out of Memory : Killed process 14215 (dbgLevelUpdater)
- BUG 15655779 - G5 not keeping the saved value for /SP/services/snmp engineid after SP reset
- BUG 15676004 - G5: Pc-Check refused to run with error: This program is only for use with Sun Microsystems hardware.
- BUG 15677100 - G5: Extra property system_identifier under /SYS/BLx
- BUG 15670499 - G5: No fault when inserting PSU and no AC power after booting up with 2 PSU
- BUG 15672996 - G5: SP not responsive after idling overnight: dynafrud memory leak.
- BUG 15694236 - G5/G5+: chassis midplane defaults to C4.
- BUG 15664464 - G5: Clean up FMOD support in ILOM
- BUG 15670704 - G5: Error reading sensor PWRBS (#06) using ipmitool kcs interface
- BUG 15681254 - G5: FRUID is not updated when dimm_ue, ioh, power supply etc. faults are reported
- BUG 15686019 - g5: 110 volt ac connected to psu does not throw fault
- BUG 15673927 - G5: does not have /conf/progparts.version on CMOD
- BUG 15673930 - G5: individual CMOD has upload firmware option in webgui
- BUG 15678370 - G5: Need to disable Ozone features and clean up other new power management features
- BUG 15627106 - G5: System Allocated Power is way much higher than the sum of Component Allocated Power
- BUG 15673894 - G5: kernel: Watchdog timer about to expire!
- BUG 15666112 - g5 REM FRU type is incorrect
- BUG 15667337 - g5: ipmitool shows hidden sensors SYS/T_AMB1 SYS/T_AMB2
- BUG 15674358 - SP hostname missing PSN
- BUG 15674363 - G5-NEM: Unsupported prepare_to_remove feature appears under NEM properties
- BUG 15680654 - G5: NEM STATE turns Power Off instead of Degraded when faulted
- BUG 15681510 - Flash updates failing and asking to retry a lot
- BUG 15667844 - G5: New 2.26.27 kernel for G5 SP and G5 BM.
- BUG 15667846 - G5: enable IPv6
- BUG 15667801 - G5: Bad HidStartRedirection reported by SQA
- BUG 15668632 - G5: ipmiflash takes 2 hours on kcs and 15 minutes on lanplus
- BUG 15617200 - G5: fruimage.xml file missing from fruid dataset snapshot: command timeout occurs.
- BUG 15676508 - G5: Event log "Inventory has been updated starting at node '/SYS' " repeats every 5 minutes
- BUG 15676514 - G5: /var/log/messages keep showing dynafru_write_install ERRORs
- BUG 15677759 - G5: REM fru disappears after SP reset
- BUG 15682625 - G5: Reset SP from CLI or WebGUI resets the hosts too, G5 Platform with Ilom r59576
- BUG 15590388 - 15sec_average of /SYS/VPS/history/ no data
- BUG 15614681 - G5: SP event log shows duplicate messages and ID sequence is out of order
- BUG 15693282 - ITP injected UE doesn't disable DIMMs
- BUG 15601082 - G5 SP intermittent Error: ipmitool ... sdr list Unable to establish LAN session
- BUG 15673997 - G5: flash intermittently hanging
- BUG 15686436 - g5: ipmiflash downgrade fails 3.0.14.17 to 3.0.9.30.a
- BUG 15686960 - G5/G5+: remove LLEM.
- BUG 15687754 - G5: reset /SP only reboots the CMOD0 SP, not CMOD1-2-3 SP.
- BUG 15602581 - G5 C4: fpgautil doesn't work for C4 NEM
- BUG 15600461 - segfault in libfrucapi
- BUG 15561775 - G5/C4: libfru support of 64bit SAS World-Wide Name
- BUG 15616939 - G5: NEM short FRU's New_Serial_Number doesn't show up for NEMs.
- BUG 15588052 - G5: CMM ECB failed I2C probe test
- BUG 15599324 - G5: Estimated upgrade time 6 minutes is too short for G5+BMs upgrade
- BUG 15679162 - Remove gemini/pegasus, wolf/hercules, G4 and Thor from trunk
- BUG 15587623 - KVMS: Redirection failure message does not tell the reason
- BUG 15608518 - ipmitool randomly receives error: Unable to establish IPMI v2 / RMCP+ session
- BUG 15590126 - RKVMS: Video Redirection fails with "Server is not ready to read" then login pop-up menu appears
- BUG 15575258 - G5-SP/C4-NEM: there needs to be UI using which users can upgrade NEM firmware from G5-SP
- BUG 15692244 - IPV6 Settings in GUI allows invalid combinations of user selectable options
- BUG 15519604 - C4: frutool/libfru enhancement for various new SEEPROMs in C4 (Diskbackplane, fan board, etc)
- BUG 15590234 - G5: /SYS/DBP/PRSNT appears in CLI & webGUI while it's not in xml & ipmi
- BUG 15590587 - Display NEM and storage blade long FRUID content in CMM
- BUG 15601416 - G5: No PSU fault diagnosed when a PSU is hot removed
- BUG 15594490 - G5: SP does not clear fault when faulted PSU has been pulled out
- BUG 15578307 - G5-NEM: CMM does not show NEM fault
- BUG 15601637 - G5: KCS ipmitool commands from host do not seem to forward from BM to SP
- BUG 15606745 - G5: faultmgmt shell missing fmadm, fmdump commands
- BUG 15582203 - C10CMM: Add dynamic FRUID support
- BUG 15584174 - G5: No fru info shows up on G5
- BUG 15596317 - fdd: No fault/clear/repair events when using fdd with plathwsvcd
- BUG 15578725 - G5: Forward IPMI messages from BM to SP
- BUG 15587135 - G5 ILOM: HDD targets showing up in /SYS/BL/REM
- BUG 15587573 - G5/C4: several issues related to /SYS/T_AMB: set command, etc...
- BUG 15587586 - G5: G5 NEM should not have cli object
- BUG 15599875 - G5: Add temperature history
- BUG 15577385 - G5-SP: hostpower script should be able to get/set host power state from SP
- BUG 15575242 - G5: need to show in G5-SP's CLI/BUI, G5-BM's ILOM version and that of the image in G5-SP's flash
- BUG 15585347 - G5: G5 Web GUI missing Host Control tab for boot device setting
- BUG 15690993 - G5/G5+: trunk BM network configuration broken.
- BUG 15571520 - Libra/G5: Revisit SP_HOLD_PWR_OFF_L on blades
- BUG 15601339 - G5 SP spdiag FAN test flase failed lower spped test
- BUG 15584708 - G5: /SYS target is missing after reset G5 SP
- BUG 15622560 - G5: Set /network/switchconf error found in event log when configure network from web GUI
- BUG 15581061 - G5 SP: SP hangs after about an hour of uptime
- BUG 15578378 - Libra/G5 BM: start /SP/console stops working.
- BUG 15606085 - G5: REM FRUID not showing up with latest P1.last
- BUG 15609002 - G5: /SYS/BLx/Py/Dz/SERVICE LED is not On when Memory ECC Errors and MRC warnings are diagnosed
- BUG 15604909 - G5: Fix Dynamic fruid to use TLI MAC address
- BUG 15605644 - G5: Web GUI Configuration -> Network Tab does not show the correct Information
- BUG 15597699 - G5: CPLD / NEM / PSU FW version doesn't look right from fru data
- BUG 15611274 - G5: Change cli to display /SYS/EMx.y instead of /SYS/BLn/PEMy
- BUG 15609389 - G5: NEM power_state is On when its power is off
- BUG 15590654 - G5: Access Blade FRUIDs from G5 SP.
- BUG 15605955 - G5: dynafru_cache_identity errors found in /var/log/messages
- BUG 15604726 - G5: Reverse Support for Chassis MAC Address allocation.
- BUG 15563531- G5: Support Chassis MAC Address allocation.
- BUG 15592615 - G5: Processing of BIOS BT OEM error messages for Nehalem EX platforms.
- BUG 15587358 - G5: fdd coredumps
- BUG 15655517 - SP fails to retain DIMM misconfig faults after blade hotplug
- BUG 15601064 - G5: healthd faults are not diagnosed
- BUG 15607138- G5: need to properly handle *box ereports and poison data-related errors
- BUG 15607146 - G5: no fault should be diagnosed for FBD_INIT_NO_MEMORY
- BUG 15584175 - G5: Need uboot diag documentation
- BUG 15559646 - G5/C4: A239 low-line support 120 vs 220 operation and status
- BUG 15586614 - G5: After CMM/SP upgrade, fans come on full blast and stay there
- BUG 15599874 - G5: LLEM, must enable bit 6 to prevent oscillation in G5
- BUG 15599904 - G5: LLEM, must set threshold bits on PSUs to indicate a 4 PSU system
- BUG 15565108 - C4: PSU presence sensors report "na"
- BUG 15568675 - G5-SP: Host serial configuration and Serial Port Sharing
- BUG 15568676 - G5 SP: /SP/reset functionality
- BUG 15579477 - G5: SP serial console start option -force not work
- BUG 15567728 - libc10blade c10 cmm and blades: A231 PSU budget is not detected correctly
- BUG 15600726 - G5: start /SP/console -script prompts confirmation question
- BUG 15585038 - G5: On board disk missing intermittently or disk is unconfigurable
- BUG 15578041 - G5: need to be able to run diagnostic tools PC-Check/spdiga/hostdiag/hostmon on G5-SP
- BUG 15593363 - g5: GUI doesn't display BIOS information properly when asking for upgrade confirmation
- BUG 15538253 - TFTP server for firmware download needs to support download SAS2 NEM firmware
- BUG 15576949 - G5 SP/C4 CMM: Factory needs ethernet switch configuration to active port 0 and disable port 1.
- BUG 15583704 - G5SP: OOM During Firmware Upgrade
- BUG 15541195 - G5 CMM: hostdiag and spdiag for multiple G5 blades.
- BUG 15597102 - pptftpd: Can't handle remote files
- BUG 15597651 - G5: Some BMs not getting upgraded when flash G5 SP - and not accessible
- BUG 15594362 - G5: Host is not off during SP upgrade, BIOS not upgraded immediately
- BUG 15575240 - G5: SP's ILOM image should build and bundle BM's as well
- BUG 15607071 - G5: BM upgrade stuck
- BUG 15583881 - NEM fw must be wrapped in a pkg in order for ILOM due to UI constraints
- BUG 15599315 - G5-NEM: use soft reset instead of hard reset after fw upgrade
- BUG 15595332 - G5 SP: xferd and frmd take a long time to start
- BUG 15601071 - G5 BM has service tags - not needed / exposed
- BUG 15601080 - G5 SP - upgrade via sunservice not resetting when finished
- BUG 15594627 - G5: usrmgt_upgrade error message shows in BM u-boot console
- BUG 15550447 - G5 Blade/Libra: Green OK LED behavior not right.
- BUG 15579207 - G5 SP / Libra : /coredump does not get auto-cleaned when reaches to /close to 100%
- BUG 15581455 - G5: add Storage Viewer support
- BUG 15583124 - G5: Missing G5 SP hardware model in Permanent environment
- BUG 15583696 - G5-Libra: BM tends to lose connection with G5 after resetting G5 SP
- BUG 15575241 - G5: blades should automatically upgrade themselves with the fw/bios/cpld bundled in SP's ILOM image
- BUG 15590505 - g5: /conf keeps getting reset
- BUG 15590331 - g5: turn cpld auto-upgrade feature off
- BUG 15575033 - Callisto/Libra: i2ctool fails when there is no mux
- BUG 15567367 - TLI: Need common startup utilities to manage product info
- BUG 15599496 - G5: setpsnc does not copy mac adress and WWN from fru
- BUG 15592209 - G5: Chassis MAC address missing leading 0 in "Product Extra"
- BUG 15606192 - Don't initialize primary container for TLI_FAILURE
- BUG 15578890 - G5 SP: No space left on device message / Segmentation fault - Coredump with firmware upgrade
- BUG 15661578 - Failed to set usentpserver value if it's not all small letters
Sun Fire X4800 Server Firmware 1.2.1
This release includes the following firmware:
Released version:
- ILOM version 3.0.14.17.a (build number 63656) (Service Processor firmware) - ILOM 3.0.14.17.a for Sun Fire X4800 Management Module (CMM)
- BIOS 11016200
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v16
- NEM SAS Expander 5.7.0.0 (requires separate manual update, and must update ILOM/BIOS first)
- OHIA 2.5.3.18
- SunVTS 7.0ps09
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.120.33-1197/BIOS 3.21.00_4.11.05.00_0x05000000
- LSI SAS-2 HBA (SGX-SAS6-EM-Z) SAS FW 05.00.29.00/BIOS 07.05.09.00
- PSU Firmware: -06 (requires separate manual sunservice access to update)
- Bugs fixed ILOM:
- 7013022 - g5 ipmi msg IP Address for OEM Command. Net Function: 0x2E (Command: 0x3E) IPAddr: 127.0.0.1
- Bugs fixed BIOS:
- 7029195 - Implement a retry mechanism for unexplained DDR training failures
Sun Fire X4800 Server Firmware 1.3
This distribution offers the software and firmware supporting Sun Fire X4800 servers. The Tools and Drivers platform contains the Tools and Drivers CD ISO image as well as common and operating system-specific files and drivers. The Firmware platform contains LSIUtil Maintenance Utility, BIOS 11016600, Integrated Lights Out Manager (ILOM) firmware 3.0.14.17a, SAS Expander Firmware 5.7.0.0, Oracle Hardware Installation Assistant 2.5.3.11, Linux Mega CLI and Linux MSM.
Installation instructions for the software and firmware are available in the product User's Guide. See the Product Notes for the latest product updates.
The firmware package ILOM-3_0_14_17_b_r64840-Sun_Fire_X4800.pkg contains:
Released version:
- ILOM version 3.0.14.17.b (build number 64840) (Service Processor firmware) - ILOM 3.0.14.17.a for Sun Fire X4800 Management Module (CMM)
- BIOS 11016600
- CPLD 7.8 and 5.8
- HPC FPGA 1.8
- PC-CHECK 6.26-s
- Hostmon 1.2.6
- NEM FPGA v17 (does not requires AC power cycle after update)
- NEM SAS Expander 5.7.0.0 manufacture image 0104 (requires separate manual update, and must update ILOM/BIOS first)
- OHIA 2.5.3.11
- SunVTS 7.0ps09
- MegaRaid (SGX-SAS6-R-REM-Z) SAS MR9262-8i FW 2.120.33-1197/BIOS 3.21.00_4.11.05.00_0x05000000
- LSI SAS-2 HBA (SGX-SAS6-EM-Z) SAS FW 05.00.29.00/BIOS 07.05.09.00
- PSU Firmware: -06 (requires separate manual sunservice access to update)
- Bugs fixed ILOM:
- BUG 15385716 - Firmware Update docs do not cite which order to do upgrade - LSI first or BIOS/SP
- BUG 15589094 - Prove Physical Presence button - no explanation in documentation as to what this is.
- BUG 15664295 - X4800:NEM hangs midplane i2c bus (One of the X4800's has ipmitool fru list not showing the Ethernet NICs.)
- BUG 15630062 - X4800: document X4800's ethernet management port usage
- BUG 15607165 - X4800: Power Button pressed event is logged when run start/stop /SYS from CLI
- BUG 15614681 - X4800: SP event log shows duplicate messages and ID sequence is out of order
- BUG 15615853 - X4800: Config restore failed for Unable to restore property '/SP/serial/host(external)/commitpending'
- BUG 15717435 - G5/G5+: NEM FPGA/GB PHY PRIOM script needed
- BUG 15655779 - X4800 not keeping the saved value for /SP/services/snmp engineid after SP reset
- BUG 15670499 - No fault when inserting PSU and no AC power after booting up with 2 PSU
- BUG 15664464 - Clean up FMOD support in ILOM
- BUG 15670704 - Error reading sensor PWRBS (#06) using ipmitool kcs interface
- BUG 15693282 - ITP injected UE doesn't disable DIMMs
- BUG 15681254 - FRUID is not updated when dimm_ue, ioh, power supply etc. faults are reported
- BUG 15686019 - 110 volt ac connected to psu does not throw fault
- BUG 15688192 - Identify mismatch of CMOD/CPU in the system
- BUG 15651769 - Fault Management needs to Fault DIMM with MRC DIMM SPD Checksum error reported by BIOS
- BUG 15673930 - individual CMOD has upload firmware option in webgui
- BUG 15678370 - Need to disable Ozone features and clean up other new power management features
- BUG 15627106 - System Allocated Power is way much higher than the sum of Component Allocated Power
- BUG 15673894 - kernel: Watchdog timer about to expire!
- BUG 15601082 - SP intermittent Error: ipmitool ... sdr list Unable to establish LAN session
- BUG 15668399 - Stop /SYS showed failed to stop /SYS message even when it worked
- BUG 15666112 - REM FRU type is incorrect
- BUG 15688802 - X4800: set /SP/cli timeout=0 to match the default on other ILOM products
- BUG 15667337 - ipmitool shows hidden sensors SYS/T_AMB1 SYS/T_AMB2 DBP/HDD*/STATE
- BUG 15673997 - flash intermittently hanging
- BUG 15674356 - Hostname changed after SP flash with preserve config option
- BUG 15674358 - SP hostname missing PSN
- BUG 15674363 - X4800-NEM: Unsupported prepare_to_remove feature appears under NEM properties
- BUG 15671078 - g5cpldflash.sh needs to move from escalation mode to service mode
- BUG 15667846 - X4800: enable IPv6
- BUG 15634397 - MRC branch fatal error doesn't fault a FRU due to failover warning
- BUG 15676466 - /SYS Properties missing product_swoRDFish_id
- BUG 15667801 - Bad HidStartRedirection reported by SQA
- BUG 15656289 - X4800 start /SP/console isn't functional when used with ldap user
- BUG 15668632 - ipmiflash takes 2 hours on kcs and 15 minutes on lanplus
- BUG 15623586 - Change Option ROM exhausted message in the ILOM log to include Bus#/Device#/Function#
- BUG 15617200 - fruimage.xml file missing from fruid dataset snapshot: command timeout occurs.
- BUG 15686960 - X4800: remove LLEM.
- BUG 15687754 - X4800: reset /SP only reboots the CMOD0 SP, not CMOD1-2-3 SP.
- BUG 15677759 - X4800: REM fru disappears after SP reset
- BUG 15686683 - prtfru for /SYS/BL* and /SYS/BL0/REM don't show up correctly
- BUG 15682625 - Reset SP from CLI or WebGUI resets the hosts too, X4800 Platform with Ilom r59576
- BUG 15590388 - 15sec_average of /SYS/VPS/history/ no data
- BUG 15686792 - fan fault shows /SYS/FMx/ERR has some incorrect values
- BUG 15648559 - Improve DRAM CE fault diagnosis granularity to a single DIMM
- BUG 15648563 - Callisto: Use uncore box error messages for procesor fault diagnosis
- BUG 15681739 - disable LLEM in PS0 when enabling LLEM in PS1
- Bugs fixed BIOS:
- BUG 15684613 - CZDAP: PTO T5140 Some PTO parts not appearing in Line Items in Oracle flow
- BUG 15641519 - X4800 system can't be powered up by I2C during DC cycling
- BUG 15638793 - [WATCH] RQT failure on 4GB Samsung/Hynix DIMM - SPD corruption
- BUG 15648207 - Enable patrol scrubbing in X4800
- BUG 15665884 - ECCs are polled at a slower rate than what's displayed in the setup
- BUG 15701743 - BIOS needs to disable ASPM in ACPI RSDT & XSDT tables
- BUG 15684327 - BIOS needs to allocate big resource for empty hotplug slots
- BUG 15690359 - Some of thermal related registers of IOH are not set correctly
- BUG 15595416 - G5: Need to remove some unused ASL code
- BUG 15644464 - G5: Update Nhm-EX microcode (for SPECweb2009 QoS failure)
- BUG 15710376 - G5: Retry BIOS (11016200) does not operate correctly in MRC serial mode
- BUG 15695797 - Disable Viral mode in G5
- BUG 15699170 - G5: 6 socket configuration shows fault.cpu.intel.quickpath.interconnect
Sun Fire X4800 Server Firmware 1.4
This distribution offers the software and firmware supporting Sun Fire X4800 servers. The Firmware platform contains BIOS 11017300, Integrated Lights Out Manager (ILOM) firmware 3.0.16.16, SAS Expander Firmware 5.7.0.0.
Installation instructions for the software and firmware are available in the product User's Guide. See the Product Notes for the latest product updates.
The firmware package ILOM-3_0_16_16_r69500-Sun_Fire_X4800.pkg contains:
Released version:
- ILOM version 3.0.16.16 (build number 69500) (Service Processor firmware) - ILOM 3.0.16.16 for Sun Fire X4800 Management Module (CMM)
- BIOS 11017300
- CPLD 7.8 and 5.8
- NEM FPGA v17 (does not require AC power cycle after update, requires separate manual update, and must update ILOM/BIOS first)
- NEM SAS Expander 5.7.0.0 manufacture image 0104 (requires separate manual update, and must update ILOM/BIOS first)
- Bugs fixed ILOM:
- 6854798 Console cannot login when 10 lumain sessions are active.
- 6907683 address of error log register for mbox failure returned by hostmon is incorrect
- 6916229 FM is not faulted when the fan speed is 0
- 6931493 SP is not able to finish booting if there's an unsupported blade in chassis
- 6931958 TEMP_FAULT is not On even though /SYS/T_AMB > upper non-recoverable high
- 6934125 ILOM faulty status and alarm_status should not disagree, even if a user clears faults
- 6978982 need to expose Niantic FEM MAC addresses in IPMI fru.
- 6987676 temp over fault failed to be cleared automatically after chassis AC power cycle
- 6999763 Slow response time performing ipmi fru print on T3-2 and T3-4
- 7005646 110 volt ac connected to psu does not throw fault
- 7014405 changing External Serial Port "Flow Control" settings doesn't stick in ILOM UI/CLI
- 7016437 lumain ALLOCPWR startup messages to be cleaned up
- 7020071 Nmap showing that ports are remaining open when they should be closed
- 7020847 ipmitool shows hidden sensors DBP/HDD*/STATE
- 7021514 Set command should not be available under /SYS/T_AMB
- 7027624 Nashua: RKVMS changing display quality produces a ghosting affect, thus degrading video quality
- 7036723 show /System on a Nashua system causes constant memory growth
- 7042634 stlistener failed to bind to TCP port 6481
- 7042846 Problem with sys-mgmt/cli
- 7061940 limited account users must not be allowed to change properties
- 7064139 Fujitsu question about why G5 system still runs with three power cords removed.
- 7065569 Need to customize NTP version string.
- 7066153 ILOM spsh hung, lumain must be restarted
- 7068581 sw 1.1 fan faults with all 4 fan modules missing
- 7070496 Resetting Defaults to Factory does not clean External Serial Port parameters
- 7073472 X4800M2 no fault LED lit when AC cords removed before HOST is powered on
- 7077479 SP Watchdog fault fault.sp.failed failed to be reported
- 7077771 PC-Check diag setting is still enabled after SP is reset to default.
- 7078049 plathwsvcd coredump when SP receives ereport.io.pciex.fatal@
- 7079579 Memory leak in libstatistics.
- 7079908 FRUID is not updated when MRC Warnings/Memory ECC/Mbox errors are diagnosed
- 7080993 NEM FRU version sometimes is blank ("FW ").
- 7082194 ILOM 3.0 Web GUI? doesn't work with Firefox 6.
- 7086029 /var/log file system full causing SP fault
- 7086123 fru_part_number has an extra "-" at the end for 8PN and bilingual FRUs
- 7086227 Lots of error logs about I2C read/write transactions in /var/log/messages.
- 7088149 Jar files should be signed for G5 SW1.4 release.
- 7089693 cpldflash utility fails with ILOM 3.0.14.17.b build 64840
- 7089740 IE 9x browser unable to input user name when adding new user
- 7092733 ilom ntpd server doesn't accept local clocks
- 7094944 /var/log/bug.log report "capidirect.c:791:parse_sensor_access():Access unknown: Const".
- 7096222 actual_power and total input power of all PSU should match
- 7096645 AC low-line fault is not cleared after AC high-line is applied.
- 7100258 tokend memory leak
- 7101110 Exadata - A generic sensor has detected an error
- 7101242 alarm_status of PS_REDUNDANCY is always cleared.
- 7103021 "hostmon BLx" on G5 SP will hang up, and also causes subsequent hostmon command hung up.
- 7103330 prtfru /SYS/BLx/Py/Dz fault FRU Message_32 value contains random junk code
- 7105252 X4470 CPU fruid data not present for X7550 2.00GHz CPUs
- 7105600 File(s) not removed when XCP transfer fails
- Bugs fixed BIOS:
- 7006582 DIMM Population Invalid not detected on BL0/P0 D11 and D15
- 7104538 smbios information for empty DIMM slot is incorrect
- 7011044 DIMM Rank Mismatch fault not detected
- 7094114 SMBIOS type 17, P0/BL0/D0 (zero) is typed as DO (O for Open)
- 7100450 Niwot problem will cause one NIC port to be disabled in BIOS boot menu
- 7105409 BIOS sometimes sends version 1 ipmi command to ILOM for UE/CE
- 7102009 When hemisphere mismatch, BIOS always sends 0x82 for branch 0 dimms, and 0x83 for branch 1 dimms
Sun Fire X4800 Server Firmware 1.5
This distribution offers the software and firmware supporting Sun Fire X4800 servers. The Firmware platform contains BIOS 11017700, Integrated Lights Out Manager (ILOM) firmware 3.0.16.16.a, SAS Expander Firmware 5.7.0.0.
Installation instructions for the software and firmware are available in the product User's Guide. See the Product Notes for the latest product updates.
The firmware package ILOM-3_0_16_16_a_r79389-Sun_Fire_X4800.pkg contains:
Released version:
- ILOM version 3.0.16.16.a (build number 79389) (Service Processor firmware) - ILOM 3.0.16.16.a for Sun Fire X4800 Management Module (CMM)
- BIOS 11017700
- CPLD 7.8 and 5.8
- NEM FPGA v17 (does not require AC power cycle after update, requires separate manual update, and must update ILOM/BIOS first)
- NEM SAS Expander 5.7.0.0 manufacture image 0104 (requires separate manual update, and must update ILOM/BIOS first)
Support for the following operating systems has been added to this release:
- Oracle Linux 5.9 and 6.4
- Oracle VM 3.2.1
- Oracle Solaris 11.1
- Bugs fixed ILOM:
- 15623493 Temporary file changes for LDAPSSL and Active Directory to prevent empty files on close failures
- 15693187 backup/restore not restoring files /conf/pam_* correctly causing ldapssl auth to fail
- 15696121 SNMP requests: 'Timeout: No Response' when host is powered off.
- 15702136 Oracle Database Appliance system getting "ERROR pam_ls_be_FileOpen: open failed file /conf/pam_ldapSSL.conf, mode rw"
- 15748471 Exadata: A generic sensor has detected an error
- 15757375 SNMP requests: 'Timeout: No Response' when host is powered off.
- 15757395 prtfru -n: "Alignment trap" messages flood /var/log/messages
- 15757730 x4800/X208: Expose read-only hostmon commands from ILOM restricted shell.
- 15757745 clearfru: error messages in /var/log/messages if the target fru is absent.
- 15764568 ILOM ports that should be closed are open temporarily during boot
- 15768776 x4800 (m2) (G5 and G5plus) service led does not turn amber with power supply fault
- 15769541 export-gpl script needs to be updated for us.oracle.com
- 15770784 X4270 M2 (Exadata) ILOM 3.0.16.10 dynafrud leaking memory
- 15812446 x4800: The PSx/S0/V_OUT_OK sensor state toggles between assert and deassert periodically
- Bugs fixed BIOS:
- 15825357 Sun CR 7206712 G5 SMBIOS memory speed values incorrect for 1600 and 800 DIMMs. Correct the algorithm.
- 15764392 Sun CR 7127252 memory device manufacturer name is truncated in OHIA Correct the structure.
- 15753737 Sun CR 7109797 Injecting pcie error causes system to reboot but no log for failure PEM slot Correct ACPI _OSC methods
- 15630291 Sun CR 6935758 G5: Inconsistent System type 3 info provided from host and SP Change reference of Board_manufacturer to Product_manufacturer.
- 15789392 Sun CR 7166046 Feature: Improve DRAM CE fault diagnosis granularity to a single DIMM
- 15684512 Sun CR 7003871 Need to update dram_ecc_per_rank_2 msg in SUNECC_Handler_FAR (SMI handler)
- 16243660: BIOS is checking reserved bitsin CMOS byte 0Dh and should not (Needed for UEK2 kernel support)
- 15826772: x4800 experiences CATERR after updating CX2 EM FW to 2.11.2000
Sun Fire X4800 Server Firmware 1.5.1
This distribution offers the software and firmware supporting Sun Fire X4800 servers. The Firmware platform contains BIOS 11017700, Integrated Lights Out Manager (ILOM) firmware 3.0.16.16.b, SAS Expander Firmware 5.7.0.0.
Installation instructions for the software and firmware are available in the product User's Guide. See the Product Notes for the latest product updates.
The firmware package ILOM-3_0_16_16_b_r86284-Sun_Fire_X4800.pkg contains:
Released version:
- ILOM version 3.0.16.16.b (build number 86284) (Service Processor firmware) - ILOM 3.0.16.16.b for Sun Fire X4800 Management Module (CMM)
- BIOS 11017700
- CPLD 7.8 and 5.8
- NEM FPGA v17 (does not require AC power cycle after update, requires separate manual update, and must update ILOM/BIOS first)
- NEM SAS Expander 5.7.0.0 manufacture image 0104 (requires separate manual update, and must update ILOM/BIOS first)
OHIA 2.5.3.37 includes:
- SGX-SAS6-R-REM-Z 12.12.0-0079
- SGX-SAS6-REM-Z FW 11.05.02.00 BIOS 07.21.04.00
Support for the following operating systems has been added to this release:
- Oracle Linux 5.10 and 6.5
- Bugs fixed ILOM:
- 18049865 - Java 7u51 requirements for RIAs
Sun Fire X4800 Server Firmware 1.5.2
This distribution offers the software and firmware supporting Sun Fire X4800 servers. The Firmware platform contains BIOS 11017700, Integrated Lights Out Manager (ILOM) firmware 3.0.16.16.c.
Installation instructions for the software and firmware are available in the product User's Guide. See the Product Notes for the latest product updates.
The firmware package ILOM-3_0_16_16_c_r89117-Sun_Fire_X4800.pkg contains:
Released version:
- ILOM version 3.0.16.16.c (build number 89117) (Service Processor firmware) - ILOM 3.0.16.16.c for Sun Fire X4800 Management Module (CMM)
- BIOS 11017700
- CPLD 7.8 and 5.8
- NEM FPGA v17 (does not require AC power cycle after update, requires separate manual update, and must update ILOM/BIOS first)
- Bugs fixed ILOM:
- 15959952 - Add SP version information to sunHwTrapFaultDiagnosed
Sun Fire X4800 Server Firmware 1.5.3
This distribution offers software and firmware supporting Sun Fire X4800 servers. The Firmware platform contains:
BIOS 11.01.78.00 Integrated Lights Out Manager (ILOM) firmware 3.0.16.16.e SAS Expander Firmware 5.7.0.0
The Oracle ILOM 3_0_16_16_e firmware package contains:
BIOS: 11017800 CPLD: 7.8 and 5.8 PC-Check: 6.29-s NEM FPGA: v17
Installation instructions for the software and firmware are available in the product User's Guide. See the Product Notes for the latest product updates.
http://docs.oracle.com/cd/E19140-01/index.html
Fixed Oracle ILOM Issues
- 18636184 HOST_AUTO_POWER_ON POLICY MISSING FROM ORACLE ILOM
- 18942522 Add option to support HOST POWER STATE CONTROL UNDER /SP/POLICY
- 18971063 Add remote host information on ipmi chassis control request in audit logs
- 18983648 Null pointer reference in sunoem cli cause seg fault+coredump of IPMI Msghndlr
- 18979043 SUNBT7167341 sp faulted because /var/log filesystem capacity
- 19129003 Thermal Trip event on CPU/IOH should be reported via ASR
- 19722223 Bash Shellshock Command Injection Vulnerability (CVE-2014-6271 and CVE-2014-7169
Sun Fire X4800 Server Firmware 1.6.0
Firmware Package
The firmware package contains:
Oracle ILOM: 3.0.16.32
BIOS: 11018000
Product Documentation
Installation instructions for the software and firmware are available within the product documentation. Refer to the Product Notes for the latest product updates. Product documentation is available at: https://docs.oracle.com/cd/E19140-01/index.html
New Features
- Enhancements to Oracle ILOM for configuring IPv4 and IPv6
- Change to the behavior of the system if Delay BIOS Upgrade is selected
New Operating Systems Support
- Oracle Linux 6.6 and 7.1
- Red Hat Linux 6.6 and 7.1
- Oracle VM 3.3.2
- Solaris 11.2
BIOS Fixed Issues
- 20174947 - Silent memory map out
- 20632201 - Mellanox CX2 MT26428 MaxPayload is set to128 bytes while capable of 256 byte
- 20604516 - Add trace points as to when the CMOS Setup during BIOS boot is requested
Oracle ILOM Fixed Issues
- 19672626 - X4800 lost all TLI container data after SP reboot
- 19707608 - Add ILOM check /flash pending X2-8 BIOS on reboot/warm reset initiated by host
- 19708267 - Slow web https access on version 3.1.2 with ssl_proxy support only
- 19708268 - Web/gui access with ILOM v3.1.2.20.c and Chrome browser
- 20157345 - X2-8 did not create FMA fault in ILOM for memory branch failure
- 20239506 - Enable/disable host console history logging doesn't work on G5
- 20578979 - Can't use Remote System Console when SSLv3 is disabled in Java
- 20917256 – Problem with ILOM platform-sw/network
- CVE-2014-6271 - Fix for CVE-2014-6271
- CVE-2014-7169 - Fix for CVE-2014-7169
- CVE-2015-0235 - Fix for CVE-2015-0235
Sun Fire X4800 Server Firmware 1.6.1
Firmware Package
The firmware package contains:
Oracle ILOM: 3.0.16.32.b
BIOS: 11018100
Product Documentation
Installation instructions for the software and firmware are available within the product documentation. Refer to the Product Notes for the latest product updates. Product documentation is available at: http://www.oracle.com/pls/topic/lookup?ctx=sfx4800
BIOS Fixed Issues
21903534 - Microcode update required
Oracle ILOM Fixed Issues
Platform ID Base ID Description
22168188 18792116 Problem with SYS-MGMT/BACKUP-RESTORE
22168419 21029277 Problem with SYS-MGMT/INFRASTRUCTURE
22168681 21773093 Problem with SYS-MGMT/LUMAIN
22168796 21124383 Problem with SYS-MGMT/INFRASTRUCTURE
22168797 21117023 Problem with SYS-MGMT/SNMP
22168799 21086241 Problem with SYS-MGMT/BACKUP-RESTORE
22168801 21115734 Problem with SYS-MGMT/INFRASTRUCTURE
22168803 21131048 Problem with SYS-MGMT/IPMI
22168805 21070440 Problem with SYS-MGMT/WEB
22168827 Javascript encoding problem
22168830 20736965 Problem with SYS-MGMT/WEB
22168862 20865877 Problem with SYS-MGMT/WEB
22169011 21078874 Problem with SYS-MGMT/WEB
22169016 20738129 Problem with SYS-MGMT/WEB
22169019 20817001 Problem with SYS-MGMT/WEB
22169021 20840007 Problem with SYS-MGMT/WEB
22169029 20840558 Problem with SYS-MGMT/WEB
22169031 20823629 Problem with SYS-MGMT/WEB
22169032 avascript errors on ldap and host control pages
22169091 20516366 Problem with SYS-MGMT/INFRASTRUCTURE
22169092 21077158 Problem with SYS-MGMT/WEB
22169093 20823761 Problem with SYS-MGMT/WEB
22169097 20828800 Problem with SYS-MGMT/WEB
22169100 20823875 Problem with SYS-MGMT/WEB
22169104 21936141 Problem with SYS-MGMT/SSH
22169159 20816954 Problem with SYS-MGMT/WEB
22169162 20823532 Problem with SYS-MGMT/WEB
Sun Fire X4800 Server Firmware 1.7.0
Firmware Package
The firmware package contains:
Oracle ILOM: 3.2.6.22
BIOS: 11070100
BIOS Fixed Issues
Bug ID Synopsis
20632201 - Mellanox CX2 MT26428 MaxPayload is set to128 bytes while capable of 256 byte
20605150 - Add trace points as to when the CMOS Setup during BIOS boot is requested
21903534 - X4800 microcode update required
22611775 - ACPI tables OEM ID and OEM Revision incorrect
Oracle ILOM Fixed Issues
PLAT ID BASE ID Synopsis
21629953 20823532 Problem with SYS-MGMT/WEB
21629968 20816954 Problem with SYS-MGMT/WEB
21653399 21615364 Problem with SYS-MGMT/LUMAIN
21653435 21029346 Problem with SYS-MGMT/INFRASTRUCTURE
21683272 21131341 Problem with SYS-MGMT/SSO
21512929 FAN faulty can't be cleared after insert a fan.
21771438 Add timestamped version of host console in snapshot
21786378 Java Remote Console does not verify server security
21819628 21676001 Problem with SYS-MGMT/INFRASTRUCTURE
21835009 21827107 Problem with SYS-MGMT/JAVARCONSOLE
21842977 Web UI not working when SP in degraded mode
21843434 X2-8/X4800 : NEM fru missing version info
21835302 ILOM SDM not showing any DIMMs
21877015 show /SYS command no longer displays product information
21867346 X2-8/X4800 : Java console failed to redirect storage
21843639 X2-8/X4800 : Power Allocation doesn't count EMs power
21842936 X2-8/X4800 : Incorrect output of /SP/serial/host/pendingspeed
21937241 21922938 Problem with SYS-MGMT/WEB
21937242 21923034 Problem with SYS-MGMT/WEB
21937482 21437710 Problem with ILOM-SYSMGMT-INFRASTRUCTURE
21954381 21936141 Problem with ILOM-SYSMGMT-SSH
21970056 20516366 Problem with ILOM
21961090 X2-8/X4800 : Launching Java Console triggers another authentication
21961869 X2-8/X4800 : Java console Caps Lock icon always off
22106638 22019672 Problem with SYS-MGMT/IPMI
22106640 22022656 Problem with SYS-MGMT/IPMI
21947215 R Console does not allow login for account other than root
21495065 BUI Left pane disappears when paging
21653399 21615364 Problem with SYS-MGMT/LUMAIN
21653435 21029346 Problem with SYS-MGMT/INFRASTRUCTURE
21683272 21131341 Problem with SYS-MGMT/SSO
21819628 21676001 Problem with SYS-MGMT/INFRASTRUCTURE
21937241 21922938 Problem with SYS-MGMT/WEB
21937242 21923034 Problem with SYS-MGMT/WEB
22106638 22019672 Problem with SYS-MGMT/IPMI
22106640 22022656 Problem with SYS-MGMT/IPMI
22190053 22046186 Problem with SYS-MGMT/IPMI
22190136 21975141 Problem with SYS-MGMT/WEB
22190142 22113061 Problem with SYS-MGMT/IPMI
22190257 22093246 Problem with SYS-MGMT/IPMI
22228095 22134052 Problem with SYS-MGMT/WEB
22228116 22150848 Problem with SYS-MGMT/RESTRICTED-SH
22249164 22081713 Problem with SYS-MGMT/IPMI
22295499 22113985 Problem with SYS-MGMT/IPMI
22302238 22226770 Problem with SYS-MGMT/WEB
22353883 22267624 Problem with SYS-MGMT/LUMAIN
22386837 22107811 Problem with SYS-MGMT/IPMI
21653435 21654005 Problem with SYS-MGMT/INFRASTRUCTURE
22451458 21963184 Problem with SYS-MGMT/IPMI
22451471 21677531 Problem with SYS-MGMT/INFRASTRUCTURE
22451491 22144453 Problem with SYS-MGMT/RESTRICTED-SH
22451506 22267464 Problem with SYS-MGMT/LUMAIN
22468398 20736906 Problem with SYS-MGMT/WEB
22542530 22449364 Problem with PLAT-SW/NETWORK
22572447 22143861 Problem with SYS-MGMT/RESTRICTED-SH
22611726 22111624 Problem with SYS-MGMT->WEB
22630290 22217313 Problem with SYS-MGMT->WEB
22649870 20867709 Problem with SYS-MGMT->WEB
22649871 21554216 Problem with SYS-MGMT->WEB
22650035 22533591 Problem with SYS-MGMT->JAVARCONSOLE
22696462 22533462 Problem with SYS-MGMT->JAVARCONSOLE
22696463 22533504 Problem with SYS-MGMT->JAVARCONSOLE
22696464 22533577 Problem with SYS-MGMT->JAVARCONSOLE
22696469 22541018 Problem with SYS-MGMT->SNMP
22696478 22553565 Problem with SYS-MGMT->INFRASTRUCTURE
22742353 22144224 Problem with SYS-MGMT->HW-SERVICES
22742813 21629291 Problem with SYS-MGMT->WEB
22750612 22353621 Problem with SYS-MGMT->INFRASTRUCTUR
Sun Fire X4800 Server Firmware 1.7.1
Firmware Package
The firmware package contains:
Oracle ILOM: 3.2.6.22.a
BIOS: 11070100
BIOS Fixed Issues:
23012300 - After update to SW 1.4 RC, 'biosconfig' hmp tool show seg fault
23012312 - After update to SW 1.4 RC, 'dmidecode' fails with no SMBIOS nor DMI entry point
Oracle ILOM Fixed Issues:
23564638 - Malformed POST header causes high CPU utilization
Sun Fire X4800 Server Firmware 1.8.0
Firmware Package
The firmware package contains:
Oracle ILOM: 3.2.7.22.a
BIOS: 11080200
BIOS Fixed Issues:
17214744 - SMBIOS reports incorrect CPU cache policy
Oracle ILOM Fixed Issues:
PLAT ID BASE ID Synopsis
22649870 20867709 Problem with SYS-MGMT/WEB
22649871 21554216 Problem with SYS-MGMT/WEB
22837036 22387611 Problem with SYS-MGMT/WEB
22846240 22239980 Problem with SYS-MGMT/SERVICETAGS
22854268 22073777 Problem with SYS-MGMT/IPMI
22935327 Login CSRF breaks SSO drilldown
22992125 22449743 Problem with PLAT-SW/NETWORK
22992156 22458888 Problem with SYS-MGMT/IPMI
22999740 22967610 Problem with SYS-MGMT/INFRASTRUCTURE
23034110 BUI: No delete confirmation alert popup while deleting user
23034111 Ilomweb: Adding groups in ldap_ssl/active directory page does not work
23034112 BUI: Ampersand (&) in password is not working
23034253 ILOM web GUI "Power Control" unable to retrieve host power state
23049928 22267502 Problem with SYS-MGMT/LUMAIN
23056974 22456037 Problem with PLAT-SW/INFRASTRUCTURE
23056975 22456050 Problem with PLAT-SW/INFRASTRUCTURE
23056977 22456071 Problem with PLAT-SW/INFRASTRUCTURE
23056979 22456090 Problem with PLAT-SW/INFRASTRUCTURE
23056980 22456129 Problem with SYS-MGMT/INFRASTRUCTURE
23065044 21109081 Problem with SYS-MGMT/BACKUP-RESTORE
23065045 22541331 Problem with SYS-MGMT/SNMP
23237826 22456025 Problem with SYS-MGMT/INFRASTRUCTURE
23237841 22456180 Problem with PLAT-SW/INSTALL
23293568 21257815 Problem with SYS-MGMT/SSH
23300095 20809290 Problem with SYS-MGMT/SSH
23300144 23088918 Problem with SYS-MGMT/SSH
23332760 22874486 Problem with SYS-MGMT/INFRASTRUCTURE
23627783 22874486 Problem with SYS-MGMT/INFRASTRUCTURE
23634836 23253109 Problem with SYS-MGMT/JAVARCONSOLE
24746126 Update tzdata to 2016g version
Sun Fire X4800 Server Firmware 2.0.0
Firmware Package
The firmware package contains:
Oracle ILOM: 4.0.2.25
BIOS: 11.08.03.00
Oracle ILOM Fixed Issues
PLAT ID BASE ID Synopsis
22504606 22504606 Problem with SYS-MGMT/INFRASTRUCTURE
24621673 24621673 Problem with SYS-MGMT/WEB
26638794 26638794 Problem with SYS-MGMT/SNMP
26950368 26949365 Problem with SYS-MGMT/IPMI
25727734 Increase the console history shown via ILOM UIs
26982167 Add support for ECDSA user keys
26993825 26661567 Problem with SYS-MGMT/INFRASTRUCTURE
27110554 Upgrade tzdata to 2017b-0
27110849 jnlp failure for remote login
Sun Fire X4800 Server Firmware 2.0.1 Bad Patched!!!!!
Firmware Package
The firmware package contains:
Oracle ILOM: 4.0.2.25
BIOS: 11.08.04.00
Oracle ILOM Fixed Issues
Sun Fire X4800 Server Firmware 2.0.1 Re-released!!
Firmware Package
The firmware package contains:
Oracle ILOM: 4.0.2.25.b
BIOS: 11.09.02.00
Oracle ILOM Fixed Issues
PLAT ID BASE ID Synopsis
27416690 27298505 Problem with SYS-MGMT/WEB
27416691 27357650 Problem with SYS-MGMT/WEB
27560742 27272895 Problem with SYS-MGMT/INFRASTRUCTURE
Oracle ILOM Fixed Issues
PLAT ID BASE ID Synopsis
27574409 Fixed Intel microcode for CVE-2017-5715
|
References
<BUG:15654409> - SUNBT6967076-3.0.9.30 G5: SINGLE-SIGN-ON IS BROKEN FOR JAVARCONSOLE
<BUG:15654649> - SUNBT6967397 THE G5 JARS NEED TO BE RE-SIGNED FOR SW 1.0.1
<BUG:15666218> - SUNBT6981424 G5: UPDATE CONSOLE REDIRECTION TO SAME AS CALLISTO
<BUG:15689584> - SUNBT7009901 G5 SW 1.2 BL AND CPU FAULTED ON 4 SOCKET SYSTEMS
<BUG:15690359> - SUNBT7010729 G5: SOME OF THERMAL RELATED REGISTERS OF IOH ARE NOT SET CORRECTLY
<BUG:15690993> - SUNBT7011402 G5/G5+: TRUNK BM NETWORK CONFIGURATION BROKEN.
<BUG:15651159> - SUNBT6962835 G5: SP VERSION 3.0.9.30 STILL SHOWING VERSION 3.0.9.11 IN CLI AND W
<BUG:15651190> - SUNBT6962871-3.0.9.30 G5: FRU DATA HAS CHANGED A LOT AFTER SP FLASHED TO BUILD 2
<BUG:15651769> - SUNBT6963650-3.0.9.25 CALLISTO: FAULT MANAGEMENT NEEDS TO FAULT DIMM WITH MRC DI
<BUG:15601064> - SUNBT6897855-X64_3.0.9 G5: HEALTHD FAULTS ARE NOT DIAGNOSED
<BUG:15601071> - SUNBT6897863-X64_3.0.9 G5 BM HAS SERVICE TAGS - NOT NEEDED / EXPOSED
<BUG:15601080> - SUNBT6897875-X64_3.0.9 G5 SP - UPGRADE VIA SUNSERVICE NOT RESETTING WHEN FINISHE
<BUG:15563531> - SUNBT6842044 G5: SUPPORT CHASSIS MAC ADDRESS ALLOCATION.
<BUG:15567728> - SUNBT6848556-TRUNK LIBC10BLADE C10 CMM AND BLADES: A231 PSU BUDGET IS NOT DETECT
<BUG:15550447> - SUNBT6819963 G5 BLADE/LIBRA: GREEN OK LED BEHAVIOR NOT RIGHT.
<BUG:15565108> - SUNBT6844637 C4: PSU PRESENCE SENSORS REPORT "NA"
<BUG:15567367> - SUNBT6848071 TLI: NEED COMMON STARTUP UTILITIES TO MANAGE PRODUCT INFO
<BUG:15655779> - SUNBT6968830 G5 NOT KEEPING THE SAVED VALUE FOR /SP/SERVICES/SNMP ENGINEID AFTER
<BUG:15688802> - SUNBT7008855 X4800 (G5): SET /SP/CLI TIMEOUT=0 TO MATCH THE DEFAULT ON OTHER ILO
<BUG:15644464> - SUNBT6954081 G5: UPDATE NHM-EX MICROCODE (FOR SPECWEB2009 QOS FAILURE)
<BUG:15644492> - SUNBT6954112 G5: EL 6 BETA REPORTS DISABLING IRQ #16
<BUG:15644791> - SUNBT6954474-X64_3.0.9 G5: PSU AC LOW LINE ISN'T FAULTED BY FAULT DIAGNOSTIC.
<BUG:15645413> - SUNBT6955271 G5: SOMETIMES FAILED TO START HOST POWER
<BUG:15686960> - SUNBT7006803-3.0.14.17 G5/G5+: REMOVE LLEM.
<BUG:15630062> - SUNBT6935471 G5: DOCUMENT G5'S ETHERNET MANAGEMENT PORT USAGE
<BUG:15631072> - SUNBT6936784-X64_3.0.9 [WATCH] G5: BM /PERSIST FULL CAUSE DIMM FRUID NOT SHOWING
<BUG:15631735> - SUNBT6937618-X64_3.0.9 G5: IMPLEMENT THE CONSOLE HISTORY FEATURE
<BUG:15632435> - SUNBT6938562 G5: BL SERVICE LED IS NOT TURNED OFF WHEN FLASH SP WHILE /SYS/SERVI
<BUG:15634397> - SUNBT6940990-X64_3.0.9 MRC BRANCH FATAL ERROR DOESN'T FAULT A FRU DUE TO FAILOVE
<BUG:15687503> - SUNBT7007477 BIOS: ACPI METHODS INCORRECTLY USE MUTEX
<BUG:15687754> - SUNBT7007753-3.0.14.17 G5: RESET /SP ONLY REBOOTS THE CMOD0 SP, NOT CMOD1-2-3 SP
<BUG:15688192> - SUNBT7008088-X64_3.0.14 G5/G5+: IDENTIFY MISMATCH OF CMOD/CPU IN THE SYSTEM.
<BUG:15669222> - SUNBT6985083 MANIPULATING USB FUNCTIONALITY CAUSES VARIOUS STRANGE RESULTS WITH
<BUG:15669264> - SUNBT6985104 MAC ADDRESSES DISPLAYED IN BIOS SETUP AND IN SP DO NOT MATCH
<BUG:15669273> - SUNBT6985109 SOME ENTRIES ARE STILL CHANGABLE WITH USER ACCESS LEVEL SET TO LIMI
<BUG:15693282> - SUNBT7014414-3.0.14.17 ITP INJECTED UE DOESN'T DISABLE DIMMS
<BUG:15677100> - SUNBT6994649-X64_3.0.14 G5: EXTRA PROPERTY SYSTEM_IDENTIFIER UNDER /SYS/BLX
<BUG:15677433> - SUNBT6995077 SMBIOS RECORDS SHOW INCOMPLETE BRAND NAME FOR SOME FIELDS
<BUG:15684362> - SUNBT7003685 G5 HAS WRONG INTERLEAVE SETTINGS IN BIOS MENU
<BUG:15684512> - SUNBT7003871 NEED TO UPDATE DRAM_ECC_PER_RANK_2 MSG IN SUNECC_HANDLER_FAR (SMI H
<BUG:15684513> - SUNBT7003872 6 CORE 4 SOCKET SYSTEM HAD A CPU ERROR
<BUG:15684613> - SUNBT7003993 CZDAP: PTO T5140 SOME PTO PARTS NOT APPEARING IN LINE ITEMS IN ORAC
<BUG:15686792> - SUNBT7006567-X64_3.0.14 G5 FAN FAULT SHOWS /SYS/FMX/ERR HAS SOME INCORRECT VALUE
<BUG:15636474> - SUNBT6943821 LIBRA: BIOS: NEED TO DISABLED USB CONTROLLER PCI FUNCTION
<BUG:15638793> - SUNBT6946921 [WATCH] RQT FAILURE ON 4GB SAMSUNG/HYNIX DIMM - SPD CORRUPTION
<BUG:15686683> - SUNBT7006418-3.0.14.17 G5: SW 1.2 PRTFRU FOR /SYS/BL* AND /SYS/BL0/REM DON'T SHO
<BUG:15640865> - SUNBT6949570 DIAGS: G5 SPDIAG VOLTEST FAILED IN RQT
<BUG:15641519> - SUNBT6950414 G5 SYSTEM CAN'T BE POWERED UP BY I2C DURING DC CYCLING
<BUG:15654998> - SUNBT6967828 G5: 2.6.32.Y BASED RHEL6/SLES11SP1: REPORT ACPI ERROR
<BUG:15600726> - SUNBT6897367-X64_3.0.9 G5: START /SP/CONSOLE -SCRIPT PROMPTS CONFIRMATION QUESTI
<BUG:15646709> - SUNBT6957008 G5 P2 UNIT HAD A MEMORY : BIOS : CONFIGURATION ERROR: MRC BRANCH ER
<BUG:15568675> - SUNBT6849947-X64_3.0.9 G5-SP: HOST SERIAL CONFIGURATION AND SERIAL PORT SHARING
<BUG:15529146> - SUNBT6783587 LIBRA BLADES MUST PROVIDE MEMORY ACPI OBJECTS
<BUG:15673894> - SUNBT6990799-X64_3.0.14 G5: KERNEL: WATCHDOG TIMER ABOUT TO EXPIRE!
<BUG:15646489> - SUNBT6956632 G5: APEI TABLE IS INVALID
<BUG:15647046> - SUNBT6957529 WRITE PROTECT SPD DATA ON SAMSUNG DIMMS
<BUG:15647987> - SUNBT6958788 G5: FALSE FAN MISSING FAULTS REPORTED ONCE FLASH SP TO BUILD 2010-2
<BUG:15673927> - SUNBT6990850-X64_3.0.14 G5: DOES NOT HAVE /CONF/PROGPARTS.VERSION ON CMOD
<BUG:15669180> - SUNBT6985034 G5: OEL: NIANTIC PEMS NO DRIVER
<BUG:15648207> - SUNBT6959120 ENABLE PATROL SCRUBBING IN G5
<BUG:15648210> - SUNBT6959124-3.0.9.30 G5: FALSE BLADE POPULATION FAULT REPORTED ON 4-SOCKET AFTE
<BUG:15648214> - SUNBT6959130 G5: P1.B CPLD UPGRADE HAS REMOTE I/O ERROR
<BUG:15668616> - SUNBT6984316 G5: RH V7 CPUSCALING FAILED ON THE NEW KERNEL.
<BUG:15675227> - SUNBT6992392 ACPI ERROR: METHOD PARSE EXECUTION FAILED AND NAMESPACE LOOKUP FAIL
<BUG:15648559> - SUNBT6959571-X64_3.0.14 CALLISTO: IMPROVE DRAM CE FAULT DIAGNOSIS GRANULARITY TO
<BUG:15667846> - SUNBT6983355-X64_3.0.14 G5: ENABLE IPV6
<BUG:15668399> - SUNBT6984054 G5: STOP /SYS SHOWED FAILED TO STOP /SYS MESSAGE EVEN WHEN IT WORKE
<BUG:15668632> - SUNBT6984331-X64_3.0.14 G5: IPMIFLASH TAKES 2 HOURS ON KCS AND 15 MINUTES ON LAN
<BUG:15601637> - SUNBT6898602-X64_3.0.9 G5: KCS IPMITOOL COMMANDS FROM HOST DO NOT SEEM TO FORWAR
<BUG:15661578> - SUNBT6975724-TRUNK FAILED TO SET USENTPSERVER VALUE IF IT'S NOT ALL SMALL LETTER
<BUG:15605644> - SUNBT6904036-X64_3.0.9 G5: WEB GUI CONFIGURATION -> NETWORK TAB DOES NOT SHOW TH
<BUG:15604909> - SUNBT6903007-X64_3.0.9 G5: FIX DYNAMIC FRUID TO USE TLI MAC ADDRESS
<BUG:15648597> - SUNBT6959617-3.0.9.30 G5: SPARE_LANE_FAILOVER FAULT POLICY
<BUG:15694236> - SUNBT7015717-X64_3.0.14 G5/G5+: CHASSIS MIDPLANE DEFAULTS TO C4.
<BUG:15695797> - SUNBT7017810 DISABLE VIRAL MODE IN G5
<BUG:15648927> - SUNBT6960024 LIBRA: SLES11SP1 HAS PROBLEM TO ENTER C3
<BUG:15673557> - SUNBT6990388 INCORRECT MESSAGE FORMAT FOR "MCA REGISTER DUMP"
<BUG:15677759> - SUNBT6995465 G5: REM FRU DISAPPEARS AFTER SP RESET
<BUG:15673930> - SUNBT6990851-X64_3.0.14 G5: INDIVIDUAL CMOD HAS UPLOAD FIRMWARE OPTION IN WEBGUI
<BUG:15676004> - SUNBT6993343 G5: PC-CHECK REFUSED TO RUN WITH ERROR: THIS PROGRAM IS ONLY FOR US
<BUG:15695798> - SUNBT7017811 8S CONFIGURATION SHOULD NOT CHECK FOR CMOS SETUP OPTION FOR "HEMISP
<BUG:15604726> - SUNBT6902751-X64_3.0.9 G5: REVERSE SUPPORT FOR CHASSIS MAC ADDRESS ALLOCATION.
<BUG:15608344> - SUNBT6907768 THERE IS NO SEL ENTRY FOR DISABLED QPI LINKS
<BUG:15608518> - SUNBT6908018-TRUNK IPMITOOL RANDOMLY RECEIVES ERROR: UNABLE TO ESTABLISH IPMI V2
<BUG:15609002> - SUNBT6908621-X64_3.0.9 G5: /SYS/BLX/PY/DZ/SERVICE LED IS NOT ON WHEN MEMORY ECC
<BUG:15609389> - SUNBT6908999-X64_3.0.9 G5: NEM POWER_STATE IS ON WHEN ITS POWER IS OFF
<BUG:15611063> - SUNBT6911271 SYSTEM LOSES MEMORY ON SOME CPU BRANCHES AFTER A REBOOT (REBOOT DUE
<BUG:15653118> - SUNBT6965286 G5: LINUX/XEN: REPORT EXTRA CPUS FOR CSTATE
<BUG:15606073> - SUNBT6904623 BLUE LED FOLLOWS DRIVE AFTER "PREPARE REMOVAL" ON SLOT
<BUG:15606085> - SUNBT6904633-X64_3.0.9 G5: REM FRUID NOT SHOWING UP WITH LATEST P1.LAST
<BUG:15606192> - SUNBT6904813-TRUNK DON'T INITIALIZE PRIMARY CONTAINER FOR TLI_FAILURE
<BUG:15606745> - SUNBT6905631-X64_3.0.9 G5: FAULTMGMT SHELL MISSING FMADM, FMDUMP COMMANDS
<BUG:15385716> - SUNBT6537282 FIRMWARE UPDATE DOCS DO NOT CITE WHICH ORDER TO DO UPGRADE - LSI FI
<BUG:15519604> - SUNBT6766579 C4: FRUTOOL/LIBFRU ENHANCEMENT FOR VARIOUS NEW SEEPROMS IN C4 (DISK
<BUG:15649550> - SUNBT6960852 G5: FAULT RESTORATION IS UNABLE TO SET BM SERVICE LED.
<BUG:15587586> - SUNBT6879392 G5: G5 NEM SHOULD NOT HAVE CLI OBJECT
<BUG:15587623> - SUNBT6879428-TRUNK KVMS: REDIRECTION FAILURE MESSAGE DOES NOT TELL THE REASON
<BUG:15682625> - SUNBT7001552-X64_3.0.14 G5: RESET SP FROM CLI OR WEBGUI RESETS THE HOSTS TOO, G5
<BUG:15684327> - SUNBT7003634 G5: BIOS NEEDS TO ALLOCATE BIG RESOURCE FOR HOTPLUG BRIDGE WHEN BOO
<BUG:15685517> - SUNBT7005012 BIOS-52 DOES NOT HANDLE DIMM SPD ERRORS CORRECTLY
<BUG:15686019> - SUNBT7005646-X64_3.0.14 G5: 110 VOLT AC CONNECTED TO PSU DOES NOT THROW FAULT
<BUG:15686436> - SUNBT7006108 G5: IPMIFLASH DOWNGRADE FAILS 3.0.14.17 TO 3.0.9.30.A
<BUG:15585347> - SUNBT6876255 G5: G5 WEB GUI MISSING HOST CONTROL TAB FOR BOOT DEVICE SETTING
<BUG:15655517> - SUNBT6968512-TRUNK SP FAILS TO RETAIN DIMM MISCONFIG FAULTS AFTER BLADE HOTPLUG
<BUG:15656091> - SUNBT6969213-3.0.9.30 G5: /SYS/SERVICE LED IS NOT TURNED ON WHEN /SYS/T_AMB > TH
<BUG:15656289> - SUNBT6969473-X64_3.0.14 G5 START /SP/CONSOLE ISN'T FUNCTIONAL WHEN USED WITH LDA
<BUG:15656466> - SUNBT6969656-3.0.9.30 G5: MEMSTORE VALUE IS NOT RESTORED AFTER RESET SP
<BUG:15656667> - SUNBT6969930-3.0.9.30 G5: CMOD STUCK AT U-BOOT FLASHING ILOM IMAGE IN A LOOP
<BUG:15658731> - SUNBT6972281 G5: SPMI HAVE WRONG BIT WIDTH
<BUG:15538253> - SUNBT6798838-TRUNK TFTP SERVER FOR FIRMWARE DOWNLOAD NEEDS TO SUPPORT DOWNLOAD S
<BUG:15541195> - SUNBT6803945-X64_3.0.9 G5 CMM: HOSTDIAG AND SPDIAG FOR MULTIPLE G5 BLADES.
<BUG:15559646> - SUNBT6835613 G5/C4: A239 LOW-LINE SUPPORT 120 VS 220 OPERATION AND STATUS
<BUG:15561775> - SUNBT6839231 G5/C4: LIBFRU SUPPORT OF 64BIT SAS WORLD-WIDE NAME
<BUG:15664464> - SUNBT6979293 G5: CLEAN UP FMOD SUPPORT IN ILOM
<BUG:15615853> - SUNBT6917474 G5: CONFIG RESTORE FAILED FOR UNABLE TO RESTORE PROPERTY '/SP/SERIA
<BUG:15665292> - SUNBT6980326 G5: BIOS SHOULD CHANGE THE DEFAULT SETTING OF DE-EMPHASIS LEVEL TO
<BUG:15665685> - SUNBT6980774 G5: MBOX ERROR SCRAPING DOESN'T REPORT UES DETECTED BY PATROL SCRUB
<BUG:15665686> - SUNBT6980775 G5: BIOS SHOULD NOT MASK BIT 22 "ERRTIMEOUT" IN BBOX ERR LOG MESSAG
<BUG:15665294> - SUNBT6980329 G5: BIOS SHOULD ENABLE THE 'EXTENDED SYNCH' IN ALL IOHS
<BUG:15665687> - SUNBT6980776 G5: IMPLEMENT "EARLY UNCORE ERROR REPORTING"
<BUG:15665884> - SUNBT6981008 ECCS ARE POLLED AT A SLOWER RATE THAN WHAT'S DISPLAYED IN THE SETUP
<BUG:15666112> - SUNBT6981303 G5 REM FRU TYPE IS INCORRECT
<BUG:15666216> - SUNBT6981422 G5: CREATE POISON FORWARDING MODE IN SETUP MENU
<BUG:15667337> - SUNBT6982755-X64_3.0.14 G5: IPMITOOL SHOWS HIDDEN SENSORS SYS/T_AMB1 SYS/T_AMB2
<BUG:15667539> - SUNBT6982995 G5: CLOCKTEST FAIL
<BUG:15616939> - SUNBT6919012-TRUNK G5: NEM SHORT FRU'S NEW_SERIAL_NUMBER DOESN'T SHOW UP FOR NEM
<BUG:15617200> - SUNBT6919378-X64_3.0.14 G5: FRUIMAGE.XML FILE MISSING FROM FRUID DATASET SNAPSHO
<BUG:15618637> - SUNBT6921159 LIBRA: EL 5.4: IB PEM DOES NOT WORK WITH 2S SYSTEM
<BUG:15621898> - SUNBT6925340-3.0.9.10 FMA SHOULD NOT FAULT PROCESSOR FOR PARITY ERRORS IN INTERN
<BUG:15622560> - SUNBT6926180 G5: SET /NETWORK/SWITCHCONF ERROR FOUND IN EVENT LOG WHEN CONFIGURE
<BUG:15622963> - SUNBT6926674 DISABLING "SRIOV AND VTD" CAUSES WINDOWS INSTALLATION TO HANG
<BUG:15623586> - SUNBT6927468-X64_3.0.14 G5: CHANGE OPTION ROM EXHAUSTED MESSAGE IN THE ILOM LOG
<BUG:15624885> - SUNBT6928996 G5 : ILOM MISSED TO REPORT FAULT ON THE DIMMS USED TO REPLACE FAULT
<BUG:15626156> - SUNBT6930631 G5 WITH EMS MAY EXPERIENCE PROBLEMS DUE TO CR 6669984
<BUG:15627106> - SUNBT6931837-X64_3.0.14 G5: SYSTEM ALLOCATED POWER IS WAY MUCH HIGHER THAN THE S
<BUG:15627196> - SUNBT6931958-X64_3.0.9 G5: TEMP_FAULT IS NOT ON EVEN THOUGH /SYS/T_AMB > UPPER N
<BUG:15628500> - SUNBT6933511-3.0.9.30 [WATCH] PRE-RQT UNIT HAD A /SYS/FM0 FAULT.CHASSIS.DEVICE.F
<BUG:15629623> - SUNBT6934927-3.0.9.10 CALLISTO/G5: DISABLE LLEM BY DEFAULT
<BUG:15630020> - SUNBT6935423 LIBRA: BIOS REPORT EXTRA CPUS IN DSDT WHEN HT IS DISABLED OR 4 SOCK
<BUG:15693428> - SUNBT7014651-SW1.2 ITP CE FAULT INJECTION DOES NOT FAULT AND DISABLE DIMM AFTER
<BUG:15692244> - SUNBT7013078-TRUNK IPV6 SETTINGS IN GUI ALLOWS INVALID COMBINATIONS OF USER SELE
<BUG:15667662> - SUNBT6983163 PRMS 41 - CREATE SMBIOS ON BOARD DEVICE EXTENDED INFORMATION TYPE
<BUG:15659634> - SUNBT6973310 FMTOPO SHOULD ENUMERATE DIMM AND LABEL THEM ON PER BLADE BASIS.
<BUG:15679162> - SUNBT6997277 REMOVE GEMINI/PEGASUS, WOLF/HERCULES, G4 AND THOR FROM TRUNK
<BUG:15678370> - SUNBT6996269-X64_3.0.14 G5: NEED TO DISABLE OZONE FEATURES AND CLEAN UP OTHER NE
<BUG:15679528> - SUNBT6997677 G5: SMBIOS REPORTS WRONG KCS BASE ADDRESS
<BUG:15607071> - SUNBT6906071-X64_3.0.9 G5: BM UPGRADE STUCK
<BUG:15607138> - SUNBT6906155-X64_3.0.9 G5: NEED TO PROPERLY HANDLE *BOX EREPORTS AND POISON DATA
<BUG:15607146> - SUNBT6906164-X64_3.0.9 G5: NO FAULT SHOULD BE DIAGNOSED FOR FBD_INIT_NO_MEMORY
<BUG:15601082> - SUNBT6897878 [WATCH] G5 SP INTERMITTENT ERROR: IPMITOOL ... SDR LIST UNABLE TO
<BUG:15601339> - SUNBT6898226 G5 SP SPDIAG FAN TEST FLASE FAILED LOWER SPPED TEST
<BUG:15601416> - SUNBT6898302-X64_3.0.9 G5: NO PSU FAULT DIAGNOSED WHEN A PSU IS HOT REMOVED
<BUG:15568676> - SUNBT6849948 G5 SP: /SP/RESET FUNCTIONALITY
<BUG:15599875> - SUNBT6896143-TRUNK G5: ADD TEMPERATURE HISTORY
<BUG:15599904> - SUNBT6896183-X64_3.0.9 G5: LLEM, MUST SET THRESHOLD BITS ON PSUS TO INDICATE A 4
<BUG:15600461> - SUNBT6897016-X64_3.0.9 SEGFAULT IN LIBFRUCAPI
<BUG:15680146> - SUNBT6998390 G5: SPDIAG RTC SET DATE AND TIME IN 12 HOUR MODE HAS NOT YET IMPLEM
<BUG:15680654> - SUNBT6999104-X64_3.0.14 G5: NEM STATE TURNS POWER OFF INSTEAD OF DEGRADED WHEN F
<BUG:15671063> - SUNBT6987258 G5 - CREATE SMBIOS PHYSICAL MEMORY ARRAY EXTENDED TYPE 144
<BUG:15669686> - SUNBT6985583 G5: SETTING BOOT DEVICE TO DEFAULT HARD DRIVE DOES NOT PUT ENTRY IN
<BUG:15669930> - SUNBT6985905 G5: REDUCE DUPLICATED "NO BOOTABLE MEDIA" LOGS
<BUG:15670499> - SUNBT6986590 G5: NO FAULT WHEN INSERTING PSU AND NO AC POWER AFTER BOOTING UP WI
<BUG:15670589> - SUNBT6986732 SETUP CLEANUP
<BUG:15670704> - SUNBT6986860 G5: ERROR READING SENSOR PWRBS (#06) USING IPMITOOL KCS INTERFACE
<BUG:15611274> - SUNBT6911475-X64_3.0.9 G5: CHANGE CLI TO DISPLAY /SYS/EMX.Y INSTEAD OF /SYS/BLN/
<BUG:15614681> - SUNBT6915976-X64_3.0.14 G5: SP EVENT LOG SHOWS DUPLICATE MESSAGES AND ID SEQUENC
<BUG:15681739> - SUNBT7000421 DISABLE LLEM IN PS0 WHEN ENABLING LLEM IN PS1
<BUG:15615159> - SUNBT6916613-X64_3.0.9 G5: PSU POWER LOSS FAULT IS NOT CLEARED WHEN POWER CABLE
<BUG:15575241> - SUNBT6859482 G5: BLADES SHOULD AUTOMATICALLY UPGRADE THEMSELVES WITH THE FW/BIOS
<BUG:15571520> - SUNBT6854089-TRUNK LIBRA/G5: REVISIT SP_HOLD_PWR_OFF_L ON BLADES
<BUG:15673036> - SUNBT6989711 HOSTDIAGS INFO HANGS WITH ILOM 59127, OUT OF MEMORY : KILLED PROCES
<BUG:15575033> - SUNBT6859257 CALLISTO/LIBRA: I2CTOOL FAILS WHEN THERE IS NO MUX
<BUG:15575242> - SUNBT6859483 G5: NEED TO SHOW IN G5-SP'S CLI/BUI, G5-BM'S ILOM VERSION AND THAT
<BUG:15575258> - SUNBT6859522 G5-SP/C4-NEM: THERE NEEDS TO BE UI USING WHICH USERS CAN UPGRADE NE
<BUG:15576949> - SUNBT6862334 G5 SP/C4 CMM: FACTORY NEEDS ETHERNET SWITCH CONFIGURATION TO ACTIVE
<BUG:15577385> - SUNBT6862934 G5-SP: HOSTPOWER SCRIPT SHOULD BE ABLE TO GET/SET HOST POWER STATE
<BUG:15590126> - SUNBT6882624-TRUNK RKVMS: VIDEO REDIRECTION FAILS WITH "SERVER IS NOT READY TO R
<BUG:15673997> - SUNBT6990950-X64_3.0.14 G5: FLASH INTERMITTENTLY HANGING
<BUG:15674356> - SUNBT6991363 G5: HOSTNAME CHANGED AFTER SP FLASH WITH PRESERVE CONFIG OPTION
<BUG:15667801> - SUNBT6983308 G5: BAD HIDSTARTREDIRECTION REPORTED BY SQA
<BUG:15667844> - SUNBT6983353 G5: NEW 2.26.27 KERNEL FOR G5 SP AND G5 BM.
<BUG:15599324> - SUNBT6895388-X64_3.0.9 G5: ESTIMATED UPGRADE TIME 6 MINUTES IS TOO SHORT FOR G5+
<BUG:15599357> - SUNBT6895423-3.0.9.30 G5: ALLOW MULTIPLE HOST SERIAL 'START /SP/CONSOLE' SESSION
<BUG:15599496> - SUNBT6895605-X64_3.0.9 G5: SETPSNC DOES NOT COPY MAC ADRESS AND WWN FROM FRU
<BUG:15599536> - SUNBT6895659 NIWOT:MSM:GUI HUNG FOR EXCESSIVE PERIOD OF TIME AFTER CABLE PULL OF
<BUG:15673550> - SUNBT6990381 BIOS IS CONFUSING CORE AND UNCORE MCA BANKS IN MCA DUMP IPMI MESSAG
<BUG:15599315> - SUNBT6895377-X64_3.0.9 G5-NEM: USE SOFT RESET INSTEAD OF HARD RESET AFTER FW UPG
<BUG:15597651> - SUNBT6893085-X64_3.0.9 G5: SOME BMS NOT GETTING UPGRADED WHEN FLASH G5 SP - AND
<BUG:15599039> - SUNBT6894955 LIBRA: EL 5.4 PCIEHP NOT WORK WITH METIS-E (EMULEX/82571 DUAL PORT)
<BUG:15597699> - SUNBT6893138-X64_3.0.9 G5: CPLD / NEM / PSU FW VERSION DOESN'T LOOK RIGHT FROM F
<BUG:15599874> - SUNBT6896141-X64_3.0.9 G5: LLEM, MUST ENABLE BIT 6 TO PREVENT OSCILLATION IN G5
<BUG:15698583> - SUNBT7021571-X64_3.0.14 G5/G5+: ITP CE FAULT INJECTION DOES NOT FAULT AND DISABL
<BUG:15674358> - SUNBT6991365-X64_3.0.14 SP HOSTNAME MISSING PSN
<BUG:15674363> - SUNBT6991369-X64_3.0.14 G5-NEM: UNSUPPORTED PREPARE_TO_REMOVE FEATURE APPEARS UN
<BUG:15675177> - SUNBT6992300 WRONG TAPS FOR THE LONGEST DIAGONAL LINKS
<BUG:15583696> - SUNBT6873611 G5-LIBRA: BM TENDS TO LOSE CONNECTION WITH G5 AFTER RESETTING G5 SP
<BUG:15651215> - SUNBT6962898 G5: THERMTRIP NEITHER LOGGED NOR DIAGNOSED AS A FAULT.
<BUG:15585038> - SUNBT6875819 G5: ON BOARD DISK MISSING INTERMITTENTLY OR DISK IS UNCONFIGURABLE
<BUG:15586614> - SUNBT6878102 G5: AFTER CMM/SP UPGRADE, FANS COME ON FULL BLAST AND STAY THERE
<BUG:15587135> - SUNBT6878801 G5 ILOM: HDD TARGETS SHOWING UP IN /SYS/BL
/REM
<BUG:15583704> - SUNBT6873624 G5SP: OOM DURING FIRMWARE UPGRADE
<BUG:15583881> - SUNBT6873876 NEM FW MUST BE WRAPPED IN A PKG IN ORDER FOR ILOM DUE TO UI CONSTRA
<BUG:15584174> - SUNBT6874420 G5: NO FRU INFO SHOWS UP ON G5
<BUG:15584175> - SUNBT6874422 G5: NEED UBOOT DIAG DOCUMENTATION
<BUG:15584708> - SUNBT6875319 G5: /SYS TARGET IS MISSING AFTER RESET G5 SP
<BUG:15699170> - SUNBT7022305 G5: 6 SOCKET CONFIGURATION SHOWS FAULT.CPU.INTEL.QUICKPATH.INTERCON
<BUG:15669356> - SUNBT6985175 SETUP MENU OPTION "EVENT LOG CONFIGURATION" SHOULD BE REMOVED
<BUG:15590654> - SUNBT6883393-TRUNK G5: ACCESS BLADE FRUIDS FROM G5 SP.
<BUG:15592209> - SUNBT6885522-X64_3.0.9 G5: CHASSIS MAC ADDRESS MISSING LEADING 0 IN "PRODUCT EXT
<BUG:15592615> - SUNBT6886075-X64_3.0.9 G5: PROCESSING OF BIOS BT OEM ERROR MESSAGES FOR NEHALEM
<BUG:15593363> - SUNBT6887040-X64_3.0.9 G5: GUI DOESN'T DISPLAY BIOS INFORMATION PROPERLY WHEN AS
<BUG:15594362> - SUNBT6888356-X64_3.0.9 G5: HOST IS NOT OFF DURING SP UPGRADE, BIOS NOT UPGRADED
<BUG:15594490> - SUNBT6888496-X64_3.0.9 G5: SP DOES NOT CLEAR FAULT WHEN FAULTED PSU HAS BEEN PUL
<BUG:15701743> - SUNBT7026045 G5: BIOS NEEDS TO DISABLE ASPM IN ACPI RSDT & XSDT TABLES
<BUG:15710376> - SUNBT7037930 G5 RETRY BIOS (11016200) DOES NOT OPERATE CORRECTLY IN MRC SERIAL M
<BUG:15675994> - SUNBT6993326 G5: RHEL 6.0 BETA SHOWS A LOT OF AER ERRORS WITH NIWOT IN "DMESG"
<BUG:15717435> - SUNBT7047462-3.0.14.17 G5/G5+: NEM FPGA/GB PHY PRIOM SCRIPT NEEDED.
<BUG:15595416> - SUNBT6889870 G5: NEED TO REMOVE SOME UNUSED ASL CODE IN DSDT OF LEGACY ACPI HOTP
<BUG:15596317> - SUNBT6891203-TRUNK FDD: NO FAULT/CLEAR/REPAIR EVENTS WHEN USING FDD WITH PLATHWS
<BUG:15597102> - SUNBT6892360-TRUNK PPTFTPD: CAN'T HANDLE REMOTE FILES
<BUG:15578307> - SUNBT6864917-TRUNK G5-NEM: CMM DOES NOT SHOW NEM FAULT
<BUG:15589094> - SUNBT6881237 PROVE PHYSICAL PRESENCE BUTTON - NO EXPLANATION IN DOCUMENTATION AS
<BUG:15578725> - SUNBT6865659 G5: FORWARD IPMI MESSAGES FROM BM TO SP
<BUG:15578890> - SUNBT6866015 G5 SP: NO SPACE LEFT ON DEVICE MESSAGE / SEGMENTATION FAULT - CORED
<BUG:15578378> - SUNBT6865004-3.0.3.11 LIBRA/G5 BM: START /SP/CONSOLE STOPS WORKING.
<BUG:15579207> - SUNBT6866630 G5 SP / LIBRA : /COREDUMP DOES NOT GET AUTO-CLEANED WHEN REACHES TO
<BUG:15579477> - SUNBT6867026-TRUNK G5: SP SERIAL CONSOLE START OPTION -FORCE NOT WORK
<BUG:15581061> - SUNBT6869441 G5 SP: SP HANGS AFTER ABOUT AN HOUR OF UPTIME
<BUG:15581455> - SUNBT6870056 DEV: G5: ADD STORAGE VIEWER SUPPORT
<BUG:15582203> - SUNBT6871182 C10CMM: ADD DYNAMIC FRUID SUPPORT
<BUG:15653334> - SUNBT6965686 G5: MISMATCH OF CPLD VERSION NEEDS TO BE FAULTED.
<BUG:15602581> - SUNBT6899941 G5 C4: FPGAUTIL DOESN'T WORK FOR C4 NEM
<BUG:15583124> - SUNBT6872695 G5: MISSING G5 SP HARDWARE MODEL IN PERMANENT ENVIRONMENT
<BUG:15594627> - SUNBT6888730-X64_3.0.9 G5: USRMGT_UPGRADE ERROR MESSAGE SHOWS IN BM U-BOOT CONSO
<BUG:15595332> - SUNBT6889776-X64_3.0.9 G5 SP: XFERD AND FRMD TAKE A LONG TIME TO START
<BUG:15587358> - SUNBT6879073 G5: FDD COREDUMPS
<BUG:15587573> - SUNBT6879378 G5/C4: SEVERAL ISSUES RELATED TO /SYS/T_AMB: SET COMMAND, ETC...
<BUG:15587298> - SUNBT6879007 G5(BQA):CANNOT LOAD RHEL5.3 IF ACPI IS DISABLED IN THE BIOS SETUP
<BUG:15679729> - SUNBT6997918 IMPLEMENT MISSED WHEA OPERATIONS
<BUG:15661890> - SUNBT6976081 G5: BIOS: PIRQ_TABLE HAS WRONG SLOTS INFO
<BUG:15664295> - SUNBT6979140 G5:NEM HANGS MIDPLANE I2C BUS
<BUG:15590505> - SUNBT6883196 G5: /CONF KEEPS GETTING RESET
<BUG:15590587> - SUNBT6883305-TRUNK DISPLAY NEM AND STORAGE BLADE LONG FRUID CONTENT IN CMM
<BUG:15648563> - SUNBT6959576-X64_3.0.14 CALLISTO: USE UNCORE BOX ERROR MESSAGES FOR PROCESOR FAU
<BUG:15676415> - SUNBT6993859 G5M2 BIOS: NEED TO DISABLED USB CONTROLLER PCI FUNCTION
<BUG:15676455> - SUNBT6993898 G5 BIOS: MODIFIED SMBIOS TYPE 9, 19 AND 41
<BUG:15676466> - SUNBT6993911 G5: /SYS PROPERTIES MISSING PRODUCT_SWORDFISH_ID
<BUG:15676508> - SUNBT6993955-X64_3.0.14 G5: EVENT LOG "INVENTORY HAS BEEN UPDATED STARTING AT NO
<BUG:15676514> - SUNBT6993961-X64_3.0.14 G5: /VAR/LOG/MESSAGES KEEP SHOWING DYNAFRU_WRITE_INSTALL
<BUG:15590234> - SUNBT6882770 G5: /SYS/DBP/PRSNT APPEARS IN CLI & WEBGUI WHILE IT'S NOT IN XML &
<BUG:15590331> - SUNBT6882889 G5: TURN CPLD AUTO-UPGRADE FEATURE OFF
<BUG:15590388> - SUNBT6882970-3.0.10.10 15SEC_AVERAGE OF /SYS/VPS/HISTORY/ NO DATA
<BUG:15652459> - SUNBT6964477 G5: JUNK CODE SHOWS IN EVENT LOG "UPDATE INVENTORY STARTING AT NODE
<BUG:15578041> - SUNBT6864196 G5: NEED TO BE ABLE TO RUN DIAGNOSTIC TOOLS PC-CHECK/SPDIGA/HOSTDIA
<BUG:15588052> - SUNBT6880055 G5: CMM ECB FAILED I2C PROBE TEST
<BUG:15588940> - SUNBT6881005 LIBRA: EL 5.4 NON XEN KERNEL CRASH WITH 1T MEMORY
<BUG:15589478> - SUNBT6881733 SUPPORT G5 SLOT-BASED MAC ADDRESS FOR ONBOARD NICS
<BUG:15671078> - SUNBT6987272-X64_3.0.14 G5CPLDFLASH.SH NEEDS TO MOVE FROM ESCALATION MODE TO SER
<BUG:15672257> - SUNBT6988721 G5PLUS: BIOS: DON'T EXPORT CPU C3
<BUG:15672996> - SUNBT6989655-X64_3.0.14 G5: SP NOT RESPONSIVE AFTER IDLING OVERNIGHT: DYNAFRUD M
<BUG:15575240> - SUNBT6859481 G5: SP'S ILOM IMAGE SHOULD BUILD AND BUNDLE BM'S AS WELL
<BUG:15672572> - SUNBT6989075 G5 PLUS: NEED TO REMOVE SOME UNUSED ASL HOTPLUG CODE IN ACPI DSDT
<BUG:15681228> - SUNBT6999781 G5: RHEL 6.0 REPORT AER WITH ERIE PEM
<BUG:15681254> - SUNBT6999809-X64_3.0.14 G5: FRUID IS NOT UPDATED WHEN DIMM_UE, IOH, POWER SUPPLY
<BUG:15681051> - SUNBT6999563 G5: CSTATE _CSD SHOULD HAVE DOMAIN ID PER PACKAGE
<BUG:15681321> - SUNBT6999911 G5: LINUX NEED SRAT TABLE CONSISTENT WITH MADT
<BUG:15681510> - SUNBT7000145 FLASH UPDATES FAILING AND ASKING TO RETRY A LOT
<BUG:15607165> - SUNBT6906176-3.0.9.11 G5: POWER BUTTON PRESSED EVENT IS LOGGED WHEN RUN START/ST
<BUG:15660453> - SUNBT6974345 SLOT ID IN SMBIOS TYPE 9 STRUCTURES NEED TO START AT 0X1
<BUG:15659914> - SUNBT6973633-3.0.9.30 G5: G5CPLDFLASH.SH CAN BRICK CMOD IF CPLD FLASH FAILS.
<BUG:15660663> - SUNBT6974623 MRC SHOULD ISSUE SMBUS STOP SYMBOL BEFORE 1ST TRANSACTION (TO SET T
<BUG:15660702> - SUNBT6974657 INCREASE IN MEMORY LATENCY WHEN PATROL SCRUBBING IS ENABLED
<BUG:15661229> - SUNBT6975306 G5: _CSD (C-STATE DEPENDENCIES) AND _TSD (T-STATE DEPENDENCIES) RET
<BUG:15605955> - SUNBT6904481-X64_3.0.9 G5: DYNAFRU_CACHE_IDENTITY ERRORS FOUND IN /VAR/LOG/MESSA
Attachments