Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1358327.1
Update Date:2018-05-14
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1358327.1 :   INTERNAL Exadata Database Machine Hardware Firmware and Patch History (V2, X2-2, X2-8)  


Related Items
  • Exadata Database Machine X2-2 Qtr Rack
  •  
  • Exadata Database Machine X2-8
  •  
  • Exadata Database Machine X2-2 Full Rack
  •  
  • Exadata Database Machine X2-2 Half Rack
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x64: EXADATA
  •  


INTERNAL reference page for Hardware support team for Exadata Database Machine V2, X2-2 and X2-8 firmware and patches.  For X3-2, X4-2, X3-8 and X4-8 (w/X4-2L), refer to Note 1501410.1. For X5-2, X4-8 (w/X5-2L), X5-8, X6-2 and X6-8 refer to Note 1998905.1. For X7-2, X7-8 refer to Note 2318642.1.

In this Document
Purpose
Scope
Details
 
 Exadata Database Machine Firmware and Image patch history - V2, X2-2 and X2-8.
 Quick Links:   V2  X2-2  X2-8  IB Switch  Rack PDU  Cisco Switch  KVM Switch
 Associated documents:
 About Exadata Patch Releases
 About Version Numbering
 Exadata OS/Firmware Image History for X2-8
 Exadata OS/Firmware Image History for X2-2
 Exadata OS/Firmware Image History for V2
 Exadata - Sun Infiniband 36P Data Center Switch Firmware
 Exadata - Sun Rack II Power Distribution Unit (PDU) Firmware
 Exadata - Cisco Catalyst 4948 / 4948EF Gigabit Ethernet Switch
 Exadata - Avocent MergePoint Unity KVM Switch.
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Exadata internal only & HW support partners

Applies to:

Exadata Database Machine X2-2 Qtr Rack - Version All Versions and later
Exadata Database Machine X2-2 Full Rack - Version All Versions and later
Exadata Database Machine V2 - Version All Versions and later
Exadata Database Machine X2-2 Half Rack - Version All Versions and later
Exadata Database Machine X2-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Purpose

This document contains the Exadata Database Machine V2, X2-2 and X2-8 Firmware and Image patch history for Hardware support.
For X3-2, X4-2, X3-8 and X4-8 (w/X4-2L) refer to Note 1501410.1.
For X5-2, X4-8 (w/X5-2L), X5-8, X6-2 and X6-8 refer to Note 1998905.1.
For X7-2, X7-8 refer to Note 2318642.1.

Scope

This note only covers Oracle Sun based hardware versions supported directly by Oracle. 
For support of Oracle Exadata Database Machine V1 based on HP hardware, please contact the GCS EEST
team which interfaces with the Hub that receives contracted support from HP for those units.

For Exadata Software assistance, refer to Internal Master Note 1274721.1

Details

Exadata Database Machine Firmware and Image patch history - V2, X2-2 and X2-8.

Quick Links:   V2  X2-2  X2-8  IB Switch  Rack PDU  Cisco Switch  KVM Switch

Associated documents:

  • NOTE 888828.1 Database Machine and Exadata Storage Server 11g Release 2 (11.2) Supported Versions
  • NOTE 888828.1 is the definitive guide to patches; this Note is intended only to provide supplemental information regarding hardware firmware versions and patch release information intended for hardware support engineers.
  • NOTE 1270094.1 for Exadata Critical Issues and associated patches.
  • NOTE 1501410.1 for Exadata Database Machine X3-2, X4-2, X3-8 and X4-8 (with X4-2L) Firmware and Image patch history
  • NOTE 1998905.1 for Exadata Database Machine X5-2, X4-8 (with X5-2L), X5-8, X6-2 and X6-8 Firmware and Image patch history
  • NOTE 2318642.1 for Exadata Database Machine X7-2 and X7-8 Firmware and Image patch history
  • NOTE 2088888.1 How to Update Disk Drive Firmware on Exadata and Recovery Appliance Compute Nodes

About Exadata Patch Releases

All firmware and patches for Exadata DB Machine are controlled and tested by Oracle DB engineering. Any
 firmware update is delivered and distributed as an Oracle DB/OEL OS patch, as Exadata has built-in
scripts (/opt/oracle.cellos/CheckHWnFWProfile) to check and re-flash the firmware to
Exadata specific versions as distributed within the OS patch. The versions qualified are critical on Exadata
Storage Servers (cells) that contain customer data so re-flashing is automatic on boot up if there are any
inconsistencies or wrong/replaced down revision parts. All firmware images and tools to flash them are
locally available within the OS file system and distributed in the image or Oracle patch.

On Storage Cells all firmware updates are done automatically during the next boot after replacement, to the
version contained in the image.

On DB nodes, the re-flashing is not automatic on boot up as it considered less critical being each node is in a RAC cluster. The best practice procedure options for updating
firmware on Database nodes after parts replacements are:

1. Check with the customer first and if they have a specific version they are using, then ask they use the
normal firmware update utility and bits they have to update to that version themselves and help them with
how if they need it. A Warning about version validation may show during boot, but it can be safely ignored.

2. If they don't care, check and update to the latest available on the Oracle download site for that part, using
normal manual update methods if there is one available. Use the built-in image script to show the versions
being checked for by the image: 

/opt/oracle.SupportTools/CheckHWnFWProfile -s

A Warning about version validation may show during boot, but it can be safely ignored until the manual
update is completed.

3. If there is no version available newer than what the checks are, then use the image bits/utilities to update
to the Exadata tested/approved image version manually using the following option similar to what the storage
nodes use:

# /opt/oracle.cellos/CheckHWnFWProfile -U /opt/oracle.cellos/iso/cellbits



Due to release cycles on Exadata, Option 2 may be preferred for ILOM/BIOS if there are bug fixes or
features not released on Exadata yet. In most cases though Option 3 is the preferred method, as all firmware
and tools are readily available as included in the image. Upon HW replacements the Field Engineer should
do f/w upgrades such that the system is left in a booted, updated state. Otherwise, updating via regularly
released image update patches is the customer's responsibility to download and update image patches,
unless they have separately purchased the ACS proactive service offering.

The only exception is Infiniband switch firmware is not contained within the images. This is a separate patch
 and manual install release via the instructions in the patch readme.

Approved and released Exadata patches can be found at MOS NOTE 888828.1. That note is the definitive guide to patches, this Note is only to provide supplemental information regarding hardware firmware versions.

The Oracle image version can be checked by running the "imageinfo"command, and the history of
images patched or updated previously can be seen with "imagehistory" command on one of the
Exadata Storage or Database Nodes:

# imageinfo

Kernel version: 2.6.18-194.3.1.0.3.el5 #1 SMP Tue Aug 31 22:41:13 EDT 2010 x86_64
Cell version: OSS_11.2.2.1.1_LINUX.X64_101105
Cell rpm version: cell-11.2.2.1.1_LINUX.X64_101105-1

Active image version: 11.2.2.1.1.101105
Active image activated: 2010-11-08 17:07:58 -0500
Active image status: success
Active system partition on device: /dev/md6
Active software partition on device: /dev/md8

About Version Numbering

Exadata images are numbered with 5 digits:  A.B.X.Y.Z.

The first two A.B correspond to the primary database release i.e 11.2 (11g) or 12.1 (12c) or 18c

The third X is the major feature release version.

The fourth Y is the minor feature release version.

The fifth Z is the patch release version.

Note: Starting September 2017, the Oracle Database changed version numbering from 11.x / 12.x to be 18.x based on the year of release.

The tables below are ordered by Version number only. The release date and version number orders may not be consistent. If a new image is deemed necessary to provide patch fixes to an earlier major.minor release version, a patch release version of an image may be released at a date later than the next major.minor feature release version. In these instances, although newer, the patch fix version may not necessarily incorporate all new firmware that the next major.minor feature release versions contain.  All listed firmware updates for a patch releases are relative to the original major.minor version of the release where noted, or the previous major.minor.patch release where not noted.

[go to top]

Exadata OS/Firmware Image History for X2-8

with x4800 or x2-8 (formerly x4800m2) DB Node and X4270M2 (X2-2) Storage Server

VersionRelease DatePatch DownloadsDetail NotesFirmware versions included
18.1.5.0.0 May 9, 2018

27503194 (Cell)
27561908 (DB Linux and OVM domU)
27561909 (DB OVM dom0)

MOS Note 2362411.1

Includes Critical Linux and Xen security fixes which includes fixes for CVE-2017-5715 (Spectre Variant 2), Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754)

Updates to 18.1.4.0.0:

  • DB X2-8 (x4800m2) SW 2.0.1
    ILOM 4.0.2.25.b
    BIOS 15.06.01.00
  • DB x4800 SW 2.0.1
    ILOM 4.0.2.25.b
    BIOS 11.09.02.00
  • Cell x4270m2 SW 1.10.0
    ILOM 3.2.11.20.a
    BIOS 08.14.01.14
18.1.4.0.0 February 1, 2018

27347059 (Cell)
27391002 (DB Linux and OVM domU)
27391003 (DB OVM dom0)

MOS Note 2348949.1

Updates to 18.1.3.0.0:

  • No new firmware updates additional to 18.1.3.0.0
18.1.3.0.0 January 4, 2018

27203979 (Cell)
27292339 (DB Linux and OVM domU)
27292341 (DB OVM dom0)

MOS Note 2341600.1

Updates to 18.1.2.0.0:

  • No new firmware updates additional to 18.1.2.0.0
18.1.2.0.0 November 22, 2017

(Re-issued November 29, 2017)

27062341 (Cell)
27103628 (DB Linux and OVM domU)
27103629 (DB OVM dom0)

MOS Note 2324358.1

Updates to 18.1.1.0.0:

  • No new firmware updates additional to 18.1.1.0.0
18.1.1.0.0 October 25, 2017

26875767 (Cell)
26923500 (DB Linux and OVM domU)
26923501 (DB OVM dom0)

MOS Note 2311786.1

Updates to 18.1.0.0.0:

  • DB X2-8 (x4800m2) SW 1.8.1
    ILOM 3.2.10.21.a
    BIOS 15.05.03.00
  • DB x4800 SW 1.11.1
    ILOM 3.2.10.21.a
    BIOS 11.08.03.00
  • Cell x4270m2 SW 1.9.0
    ILOM 3.2.10.24
    BIOS 08.14.01.13
18.1.0.0.0 October 3, 2017

25342756 (Cell)
26829586 (DB Linux and OVM domU)
26829591 (DB OVM dom0)

MOS Note 2288392.1

New major feature image release with feature support for Oracle Database 18c with new version numbering scheme based on year of release similar to Oracle Database.

Support for EAEU 8TB disk models as FRU's - See MOS Note 2309387.1 for details.

Updates to 12.2.1.1.2:

  • Disks -
    Hitachi 8TB SAS - PD51 (H7280A520 model)
    Hitachi 8TB SAS EAEU - C376 (H7280A524 model)

12.2.1.1.7 May 9, 2018

27503198 (Cell)
27561867 (DB Linux and OVM domU)
27561868 (DB OVM dom0)

MOS Note 2362410.1

Includes Critical Linux and Xen security fixes which includes fixes for CVE-2017-5715 (Spectre Variant 2), Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754) and 12.2 support for 8TB disk alternate and EAEU models.

Updates to 12.2.1.1.6:

  • DB X2-8 (x4800m2) SW 2.0.1
    ILOM 4.0.2.25.b
    BIOS 15.06.01.00
  • DB x4800 SW 2.0.1
    ILOM 4.0.2.25.b
    BIOS 11.09.02.00
  • Cell x4270m2 SW 1.10.0
    ILOM 3.2.11.20.a
    BIOS 08.14.01.14
  • Disks -
    Hitachi 8TB SAS - PD51 (H7280A520 model)
    Hitachi 8TB SAS EAEU - C376 (H7280A524 model)

12.2.1.1.6 February 1, 2018

27351065 (Cell)
27390990 (DB Linux and OVM domU)
27390991 (DB OVM dom0)

MOS Note 2348948.1

Updates to 12.2.1.1.5:

  • No new firmware updates additional to 12.2.1.1.5
12.2.1.1.5 January 4, 2018

27203983 (Cell)
27292320 (DB Linux and OVM domU)
27292321 (DB OVM dom0)

MOS Note 2341587.1

Updates to 12.2.1.1.4:

  • No new firmware updates additional to 12.2.1.1.4
12.2.1.1.4 November 22, 2017

(Re-issued November 28, 2017)

27032747 (Cell)
27103625 (DB Linux and OVM domU)
27103627 (DB OVM dom0)

MOS Note 2324367.1

Updates to 12.2.1.1.3:

  • No new firmware updates additional to 12.2.1.1.3
12.2.1.1.3 October 25, 2017

26671200 (Cell)
26774227 (DB Linux and OVM domU)
26774228 (DB OVM dom0)

MOS Note 2300276.1

Updates to 12.2.1.1.2:

  • DB X2-8 (x4800m2) SW 1.8.1
    ILOM 3.2.10.21.a
    BIOS 15.05.03.00
  • DB x4800 SW 1.11.1
    ILOM 3.2.10.21.a
    BIOS 11.08.03.00
  • Cell x4270m2 SW 1.9.0
    ILOM 3.2.10.24
    BIOS 08.14.01.13
12.2.1.1.2 July 2017

26027495 (Cell)
26151721 (DB Linux and OVM domU)
26151722 (DB OVM dom0)

MOS Note 2270791.1

Support for new 8TB disk model FRU.

Updates to 12.2.1.1.1:

  • DB X2-8 (x4800m2) SW1.8.0
    ILOM 3.2.10.21
    BIOS 15.05.03.00
  • DB x4800 SW 1.11.0
    ILOM 3.2.10.21
    BIOS 11.08.03.00
  • Disks -
    Hitachi 8TB SAS - A374 (H7280B520 model)

12.2.1.1.1 April 2017

25512521 (Cell)
25640941 (DB Linux and OVM domU)
25640948 (DB OVM dom0)

MOS Note 2231247.1

Updates to 12.2.1.1.0:

  • DB X2-8 (x4800m2) SW1.7.0
    ILOM 3.2.9.25
    BIOS 15.05.03.00
  • DB x4800 SW 1.10.0
    ILOM 3.2.9.25
    BIOS 11.08.03.00
  • Disks -
    Hitachi 8TB SAS - PAG1 (H7280A520 model)

12.2.1.1.0 January 2017

21052028 (Cell)
25463013 (DB Linux and OVM domU)
25463019 (DB OVM dom0)

MOS Note 2207148.1

New major feature image release with feature support for Oracle Database 12.2c Release 2.

Updates to 12.1.2.3.4:

  • DB X2-8 (x4800m2) SW1.5.0+
    ILOM 3.2.7.22.b r113564
    BIOS 15.05.03.00
  • DB x4800 SW1.8.0+
    ILOM 3.2.7.22.b r113564
    BIOS 11.08.03.00
12.1.2.3.7 October 25, 2017

26739595 (Cell)
26774178 (DB Linux and OVM domU)
26774179 (DB OVM dom0)

MOS Note 2305709.1

Updates to 12.1.2.3.6:

  • DB X2-8 (x4800m2) SW 1.8.1
    ILOM 3.2.10.21.a
    BIOS 15.05.03.00
  • DB x4800 SW 1.11.1
    ILOM 3.2.10.21.a
    BIOS 11.08.03.00
  • Cell x4270m2 SW 1.9.0
    ILOM 3.2.10.24
    BIOS 08.14.01.13
12.1.2.3.6 July 2017

26027499 (Cell)
26151718 (DB Linux and OVM domU)
26151719 (DB OVM dom0)

MOS Note 2270790.1

Support for new 8TB disk model FRU.

Updates to 12.1.2.3.5:

  • DB X2-8 (x4800m2) SW1.8.0
    ILOM 3.2.10.21
    BIOS 15.05.03.00
  • DB x4800 SW 1.11.0
    ILOM 3.2.10.21
    BIOS 11.08.03.00
  • Disks -
    Hitachi 8TB SAS - A374 (H7280B520 model)

12.1.2.3.5 April 2017

25509078 (Cell)
25640844 (DB Linux and OVM domU)
25640846 (DB OVM dom0)

MOS Note 2231245.1

Updates to 12.1.2.3.4:

  • DB X2-8 (x4800m2) SW1.7.0
    ILOM 3.2.9.25
    BIOS 15.05.03.00
  • DB x4800 SW 1.10.0
    ILOM 3.2.9.25
    BIOS 11.08.03.00
  • Disks -
    Hitachi 8TB SAS - PAG1 (H7280A520 model)

12.1.2.3.4 January 2017

25031476 (Cell)
25093501 (DB Linux and OVM domU)
25093502 (DB OVM dom0)

MOS Note 2203610.1

Updates to 12.1.2.3.3:

  • No new firmware updates additional to 12.1.2.3.3
12.1.2.3.3 December 2016 (161208 label)

November 2016 (161109 label)

October 2016 (161013 label)

24441458 (Cell)
24669306 (DB Linux and OVM domU)
24669307 (DB OVM dom0)

MOS Note 2181366.1

*** 12.1.2.3.3 was re-spun and re-released in November, primarily for security bug fixes. This was re-spun again in December, not adding any additional firmware. There are no firmware updates specifically for V2/X2-2/X2-8. The specific bug fix list is contained in the README for Patch 24441458.

Updates to 12.1.2.3.2:

  • DB X2-8 (x4800m2) SW1.5.0
    ILOM 3.2.7.22.a
    BIOS 15.05.01.00
  • DB x4800 SW 1.8.0
    ILOM 3.2.7.22.a
    BIOS 11.08.02.00
  • Cell x4270m2 SW 1.8.0
    ILOM 3.2.7.30.a
    BIOS 08.14.01.12
  • Disks -
    Hitachi 600GB SAS - A8C0
12.1.2.3.2 July 2016

23200959 (Cell)
23564643 (DB Linux and OVM domU)
23564644 (DB OVM dom0)

MOS Note 2133207.1

 

Updates to 12.1.2.3.1:

  • DB X2-8 (x4800m2) SW1.4.1
    ILOM 3.2.6.22.a
    BIOS 15.04.01.00
  • DB x4800 SW 1.7.1
    ILOM 3.2.6.22.a
    BIOS 11.07.01.00
  • Cell x4270m2 SW 1.7.7
    ILOM 3.1.2.54
    BIOS 08.14.01.11
  • Disks -
    Hitachi 8TB SAS - P9E2 (H7280A520 model)
    Hitachi 4TB SAS - A3A0
    Hitachi 600GB SAS - A820
12.1.2.3.1 April 2016
(Cell image re-issued July 2016)

24306177 (Cell)
22954700 (DB Linux and OVM domU)
22954703 (DB OVM dom0)

MOS Note 2124734.1

Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.

Updates to 12.1.2.3.0:

  • DB X2-8 (x4800m2) SW1.4.0
    ILOM 3.2.6.22
    BIOS 15.04.01.00
  • DB x4800 SW 1.7.0
    ILOM 3.2.6.22
    BIOS 11.07.01.00
  • Disks - 
    Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
One-off MLR patches

March 2016

(Withdrawn July 2016)

WITHDRAWN - Refer to MOS Note 2073916.1 for details.

One-off MLR patches for various image releases to address Exadata Critical Issues 1270094.1 EX25 (and EX28). EX28 is not specifically applicable to X2-8, however the EX25 firmware is bundled in the same patch.

The patches will update the cell and cell rpm version date string (not the image version number or date) and will also update the firmware bundle file and CheckHWnFWProfile check scripts within the image.

These patches were withdrawn in July 2016 due to EX29.

Updates to 12.1.2.2.0, 12.1.2.2.1, 12.1.2.3.0:

  • Disks -
    Hitachi 600GB SAS - A880 (Withdrawn)
12.1.2.3.0 February 2016

21749993 (Cell)
22750145 (DB Linux and OVM domU)
22750142 (DB OVM dom0)

MOS Note 2049743.1

 

  • DB X2-8 (x4800m2) SW1.3.1
    ILOM 3.0.16.34.b
    BIOS 15.02.09.00
  • DB x4800 SW 1.6.1
    ILOM 3.0.16.32.b
    BIOS 11.01.81.00
  • LSI HBA firmware package - 12.12.0-0243
  • Disks - 
    Hitachi 8TB SAS - P901 (H7280A520 model)
    Hitachi 600GB SAS - A820
12.1.2.2.3 July 2016

23217781 (Cell)
23557378 (DB Linux and OVM domU)
23557379 (DB OVM dom0)

MOS Note 2133208.1

 

Updates to 12.1.2.2.2:

  • DB X2-8 (x4800m2) SW1.4.1
    ILOM 3.2.6.22.a
    BIOS 15.04.01.00
  • DB x4800 SW 1.7.1
    ILOM 3.2.6.22.a
    BIOS 11.07.01.00
  • Cell x4270m2 SW 1.7.7
    ILOM 3.1.2.54
    BIOS 08.14.01.11
  • Disks - 
    Hitachi 8TB SAS - P9E2 (H7280A520 model)
    Hitachi 4TB SAS - A3A0
    Hitachi 600GB SAS - A820
12.1.2.2.2 April 2016
(Cell image re-issued in July 2016)

24306258 (Cell)
22929395 (DB Linux and OVM domU)
22929396 (DB OVM dom0)

MOS Note 2124710.1

Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.

Updates to 12.1.2.2.1:

  • DB X2-8 (x4800m2) SW1.4.0
    ILOM 3.2.6.22
    BIOS 15.04.01.00
  • DB x4800 SW 1.7.0
    ILOM 3.2.6.22
    BIOS 11.07.01.00
  • Disks - 
    Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
12.1.2.2.1 January 2016

22106928 (Cell)
22277123 (DB Linux and OVM domU)
22277124 (DB OVM dom0)

MOS Note 2094446.1

 

Updates to 12.1.2.2.0:

  • No new firmware updates additional to 12.1.2.2.0
12.1.2.2.0 September 2015

20131726 (Cell)
21825906 (DB Linux and OVM domU)
21825879 (DB OVM dom0)

MOS Note 2038073.1

Includes support for 8TB disks, IPv6, ExaCLI utility, patchmgr use for DB node updates.

  • DB X2-8 (x4800m2) SW1.3.0
    ILOM 3.0.16.34
    BIOS 15.02.08.00
  • DB x4800 SW 1.6.0
    ILOM 3.0.16.32
    BIOS 11.01.80.00
  • Cell x4270m2 SW1.7.5
    ILOM 3.1.2.20.g
    BIOS 08.14.01.09
  • LSI HBA firmware package - 12.12.0-0229
  • Disks - 
    Hitachi 8TB SAS - P554 (H7280A520 model)
    Hitachi 600GB SAS - A7E0
12.1.2.1.3 October 2015

21446295 (Cell)
21821557 (DB Linux and OVM domU)
21821610 (DB OVM dom0)

MOS Note 2031447.1

ILOM security fixes.

Updates to 12.1.2.1.2:

  • DB X2-8 (x4800m2) SW1.3.0
    ILOM 3.0.16.34
    BIOS 15.02.08.00
  • DB x4800 SW 1.6.0
    ILOM 3.0.16.32
    BIOS 11.01.80.00
  • Cell x4270m2 SW1.7.5
    ILOM 3.1.2.20.g
    BIOS 08.14.01.09
12.1.2.1.2 June 2015

20748218  (Cell)
21151982 (DB Linux)
21151986 (DB OVM)
16486998 (Latest dbnodeupdate.sh)

MOS Note 2014306.1

Updates to 12.1.2.1.1:

  • No new firmware updates additional to 12.1.2.1.0
12.1.2.1.1 (12c) March 2015 20240049 (Cell)
20746761 (DB ULN)
16486998 (Latest dbnodeupdate.sh)

MOS Note 1959143.1

 

Updates to 12.1.2.1.0:

  • No new firmware updates additional to 12.1.2.1.0
12.1.2.1.0 (12c) December 2014 17885582 (Cell)
20170913 (DB ULN)
16486998 (Latest dbnodeupdate.sh)

MOS Note 1947476.1

 

  • DB X2-8 (x4800m2) SW1.2.3
    ILOM 3.0.16.20.g
    BIOS 15.02.06.00
  • DB x4800 SW 1.5.3
    ILOM 3.0.16.16.e
    BIOS 11.01.78.00
  • Cell x4270m2 SW1.7.3.1
    ILOM 3.1.2.20.e
    BIOS 08.14.01.05
  • IB HCA -
    DB x4800 & X2-8 (x4800m2) 2.11.2014
    Cell x4270m2 2.11.2012
  • Disks -
    Hitachi 4TB SAS - A2D2
    Hitachi 3TB SAS - A6C0
    Hitachi 2TB SAS - A6C0
    Hitachi 600GB SAS - A7A0
12.1.1.1.2 (12c) April 2015 20699031

MOS Note 1995937.1

 

Updates to 12.1.1.1.1:

  • Disks - 
    Hitachi 4TB SAS - A2D2
    Hitachi 3TB SAS - A6C0
    Hitachi 2TB SAS - A6C0
    Hitachi 600GB SAS - A7A0
12.1.1.1.1 (12c) July 2014 18084575

MOS Note 1667407.1

Includes support for 4TB SAS disk upgrades to X2-2 Storage Servers.

  • DB X2-8 (x4800m2) SW1.2.2
    ILOM 3.0.16.20.e
    BIOS 15.02.05.00
  • DB x4800 SW 1.5.2
    ILOM 3.0.16.16.c
    BIOS 11.01.77.00
  • Cell x4270m2 SW1.7.3
    ILOM 3.1.2.20.c
    BIOS 08.14.01.05
  • Flash F20 / F20 M2 - LSI 1.27.96
  • Disks - 
    Hitachi 4TB SAS - A260
    Hitachi 3TB SAS - A690
    Hitachi 2TB SAS - A690
12.1.1.1.0 (12c)  December 2013 16980054 (Cell)
17997668 (DB)

MOS Note 1571789.1

Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.

Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).

Note: 12.1.1.1.0 provides additional features for customers running Oracle 12c database, and would be optionally installed to replace 11.2.x.x.x. This was released concurrently with 11.2.3.3.0.

  • DB X2-8 (x4800m2) SW1.2
    ILOM 3.0.16.20.c
    BIOS 15.02.05.00
  • DB x4800 SW1.5
    ILOM 3.0.16.16.a
    BIOS 11.01.77.00 
  • Cell x4270m2 SW1.7.2
    ILOM 3.1.2.20.b
    BIOS 08.14.01.03
  • IB HCA 2.11.2010
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
11.2.3.3.1 (11g) June 2014 19166601 (Cell)
18876946 (DB ULN)

MOS Note 1667414.1

Incorporates the latest available firmware for all hardware, including firmware updates.

Includes support for 4TB SAS disk upgrades to X2-2 Storage Servers.

  • DB X2-8 (x4800m2) SW1.2.2
    ILOM 3.0.16.20.e
    BIOS 15.02.05.00
  • DB x4800 SW 1.5.2
    ILOM 3.0.16.16.c
    BIOS 11.01.77.00
  • Cell x4270m2 SW1.7.3
    ILOM 3.1.2.20.c
    BIOS 08.14.01.05
  • Flash F20 / F20 M2 - LSI 1.27.96
  • Disks - 
    Hitachi 4TB SAS - A260
    Hitachi 3TB SAS - A690
    Hitachi 2TB SAS - A690
11.2.3.3.0 (11g) December 2013 16278923 (Cell)
17809253 (DB)

MOS Note 1487339.1

Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.

Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).

Note: 11.2.3.3.0 was the default version intended for customers running Oracle 11g database. 12.1.1.1.0 was released concurrently and provides additional features for customers running Oracle 12c database.

  • DB X2-8 (x4800m2) SW1.2
    ILOM 3.0.16.20.c
    BIOS 15.02.05.00
  • DB x4800 SW1.5
    ILOM 3.0.16.16.a
    BIOS 11.01.77.00 
  • Cell x4270m2 SW1.7.2
    ILOM 3.1.2.20.b
    BIOS 08.14.01.03
  • IB HCA 2.11.2010
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
11.2.3.2.2 March 2014 17953347 (Cell)
18205376 (DB)

MOS Note 1608581.1

Incorporates major firmware updates and several other critical fixes previously in various MLR patches.

  • DB X2-8 (x4800m2) SW1.2
    ILOM 3.0.16.20.c
    BIOS 15.02.05.00
  • DB x4800 SW1.5
    ILOM 3.0.16.16.a
    BIOS 11.01.77.00
  • IB HCA 2.11.2010
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
  • Disks -
    Hitachi 3TB SAS - A600
    Hitachi 2TB SAS - A600
    Hitachi 600GB SAS - A780
One-off MLR patch March 2014 17878822

Standalone patch for LSI firmware to address 'chip pause' issue.  Applies to 11.2.3.2.1 image only, and does not update the image version, just the firmware.

  • LSI HBA firmware package - 12.12.0-0178
One-off MLR patches July - Dec 2013 17201499
<WITHDRAWN>

[WITHDRAWN: Do not use due to Flash firmware 1.27.94 issues]

Standalone patch for critical software and firmware bug fixes.  Updates software RPMs, Aura card firmware, and LSI firmware.  Applies to 11.2.3.2.1 image only, and does not update the image version, just the RPMs, and firmware.  

Note: CheckHWnFWProfile script does not get updated.

  • LSI HBA firmware package - 12.12.0-0172
  • Flash F20 / F20 M2 - LSI 1.27.94
11.2.3.2.1 January 2013 14522699 (Cell)
16432033 (DB)

MOS Note 1485475.1

Incorporates the firmware updates previously in the one-off firmware-only patch.

Option to prevent database server hot spare disk reclaim.

ILOM Memory Leak and PCI Riser BIOS fixes.

ILOM compatability for X2-8 (x4800m2) RoHS Power Supply FRU.

  • DB X2-8 (x4800m2) SW1.1.2
    ILOM 3.0.16.20.b
    BIOS 15.01.32.00
  • Cell x4270m2 SW1.6.1
    ILOM 3.0.16.10.d
    BIOS 08.12.01.04
  • LSI HBA firmware package - 12.12.0-0140
  • Flash F20 / F20 M2 - FMOD D21Y
  • Disks -
    Hitachi 3TB SAS - A310
    Hitachi 2TB SAS - A310
    Hitachi 600GB SAS - A700
One-off Firmware November 2012 14793859

Standalone patch for ILOM and Flash MOD firmware. Applies to any older image, and does not update the image version, just the firmware and CheckHWnFWProfile script.

MOS Note 1504776.1

  • Cell x4270m2 SW1.6.1
    ILOM 3.0.16.10.d
    BIOS 08.12.01.04
  • Flash F20 / F20 M2 - FMOD D21Y
11.2.3.2.0 September 2012 14212264

MOS Note 1468877.1

Write-back Smart Flash Cache

Solaris 11 is no longer supported on X2-8.

  • DB X2-8 (x4800m2) SW1.1.1
    ILOM 3.0.16.20.a
    BIOS 15.01.32.00
  • Disks -
    Seagate 600GB SAS - 0B25
11.2.3.1.1  June 2012 13998727 MOS Note 1466459.1
  • No new firmware updates additional to 11.2.3.1.0
11.2.3.1.0 March 2012 13536739 MOS Note 1429907.1

Solaris 11 support for  FCS version plus SRU2 plus IDR's.

Linux OS updates now provided via ULN
  • DB x4800 SW1.4
    ILOM 3.0.16.16
    BIOS 11.01.73.00
  • DB X2-8 (x4800m2) SW1.1
    ILOM 3.0.16.20
    BIOS 15.01.28.00
  • LSI HBA firmware package - 12.12.0-0079
  • Disks -
    Seagate 600GB SAS - 0A25; Hitachi 600GB SAS - A6C0
11.2.2.4.2 December 2011 13513611 MOS Note 1388400.1

Support for 3TB SAS disks in Storage Cells

Patches for 10GbE issue, ntpd and flash drives no longer accessible after 6 months uptime.
  • Disks -
    Seagate 3TB SAS - 064A; Hitachi 3TB SAS - A142
11.2.2.4.1 December 2011 13444164 MOS Note 1381730.1

Support for mixed drive vendor support in Storage Cells
  • Disks -
    Hitachi 600GB SAS - A5C8
    Hitachi 2TB SAS - A142
11.2.2.4.0 October 2011 12708838 MOS Note 1348647.1

Solaris 11 Express SRU10 update; and Smart Flash Cache and Flash Log features added

Support for X2-8 (X4800m2) DB nodes.
  • DB x4800 SW1.3
    ILOM 3.0.14.17.b
    BIOS 11.01.62.00
  • DB X2-8 (x4800m2) SW1.0
    ILOM 3.0.14.25
    BIOS 15.01.23.00
  • Cell x4270m2 SW1.4
    ILOM 3.0.16.10
    BIOS 08.08.01.02
  • Disks -
    Seagate 2TB SAS - 061A
11.2.2.3.5 August 2011 12849110 MOS Note 1334254.1

Patch release with new IB OFED stack that fixes a kernel panic on db nodes
  • No new firmware updates additional to 11.2.2.3.2
11.2.2.3.3 July 2011 Factory only release New verify-topology to support storage expansion racks
  • No new firmware updates additional to 11.2.2.3.2
11.2.2.3.2 May 2011 12577723 MOS Note 1323958.1

New major release with dual-boot image support Solaris on DB nodes option during install.  OFED stack updated.
  • DB x4800 SW1.2.1
    ILOM 3.0.14.17.a
    BIOS 11.01.62.00
  • Cell x4270m2 SW1.3
    ILOM 3.0.14.11.b
    BIOS 08.06.01.08
  • IB HCA 2.7.81.30
  • LSI HBA firmware package - 12.12.0-0048
  • Flash F20 - LSI 1.27.92 FMOD D20Y
11.2.2.2.2 March 2011 11721471 MOS Note 1292030.1

patch release for db and cell base image
  • No new firmware updates additional to 11.2.2.2.0
11.2.2.2.0 December 13, 2010 Original Factory Release OEL 5.5 Unbreakable Kernel, Oracle DB11.2.0.2
  • DB x4800 SW1.1
    ILOM 3.0.9.30.a
    BIOS 11.01.41.00
  • Cell x4270m2 SW1.2.1
    ILOM 3.0.9.27.a
    BIOS 08.04.02.03
  • IB HCA 2.7.81.0
  • LSI HBA firmware package 12.9.0.0049
  • Disks -
    Seagate 600GB SAS 0805;
    Seagate 2TB SAS 0514
  • Flash F20 - LSI 1.27.91 FMOD D20Y

[go to top]

Exadata OS/Firmware Image History for X2-2

VersionRelease DatePatch DownloadsDetail NotesFirmware versions included
18.1.5.0.0 May 9, 2018

27503194 (Cell)
27561908 (DB Linux and OVM domU)
27561909 (DB OVM dom0)

MOS Note 2362411.1

Includes Critical Linux and Xen security fixes which includes fixes for CVE-2017-5715 (Spectre Variant 2), Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754).

Updates to 18.1.4.0.0:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW 1.10.0
    ILOM 3.2.11.20.a
    BIOS 08.14.01.14
18.1.4.0.0 February 1, 2018

27347059 (Cell)
27391002 (DB Linux and OVM domU)
27391003 (DB OVM dom0)

MOS Note 2348949.1

Updates to 18.1.3.0.0:

  • No new firmware updates additional to 18.1.3.0.0
18.1.3.0.0 January 4, 2018

27203979 (Cell)
27292339 (DB Linux and OVM domU)
27292341 (DB OVM dom0)

MOS Note 2341600.1

Updates to 18.1.2.0.0:

  • No new firmware updates additional to 18.1.2.0.0
18.1.2.0.0 November 22, 2017

(Re-issued November 29, 2017)

27062341 (Cell)
27103628 (DB Linux and OVM domU)
27103629 (DB OVM dom0)

MOS Note 2324358.1

Updates to 18.1.1.0.0:

  • No new firmware updates additional to 18.1.1.0.0
18.1.1.0.0 October 25, 2017

26875767 (Cell)
26923500 (DB Linux and OVM domU)
26923501 (DB OVM dom0)

MOS Note 2311786.1

Updates to 18.1.0.0.0:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW 1.9.0
    ILOM 3.2.10.24
    BIOS 08.14.01.13
18.1.0.0.0 October 3, 2017

25342756 (Cell)
26829586 (DB Linux and OVM domU)
26829591 (DB OVM dom0)

MOS Note 2288392.1

New major feature image release with feature support for Oracle Database 18c with new version numbering scheme based on year of release similar to Oracle Database.

Support for EAEU 8TB disk models as FRU's - See MOS Note 2309387.1 for details.

Updates to 12.2.1.1.2:

  • Disks -
    Hitachi 8TB SAS - PD51 (H7280A520 model)
    Hitachi 8TB SAS EAEU - C376 (H7280A524 model)

12.2.1.1.7 May 9, 2018

27503198 (Cell)
27561867 (DB Linux and OVM domU)
27561868 (DB OVM dom0)

MOS Note 2362410.1

Includes Critical Linux and Xen security fixes which includes fixes for CVE-2017-5715 (Spectre Variant 2), Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754) and 12.2 support for 8TB disk alternate and EAEU models.

Updates to 12.2.1.1.6:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW 1.10.0
    ILOM 3.2.11.20.a
    BIOS 08.14.01.14
  • Disks -
    Hitachi 8TB SAS - PD51 (H7280A520 model)
    Hitachi 8TB SAS EAEU - C376 (H7280A524 model)

12.2.1.1.6 February 1, 2018

27351065 (Cell)
27390990 (DB Linux and OVM domU)
27390991 (DB OVM dom0)

MOS Note 2348948.1

Updates to 12.2.1.1.5:

  • No new firmware updates additional to 12.2.1.1.5
12.2.1.1.6 February 1, 2018

27351065 (Cell)
27390990 (DB Linux and OVM domU)
27390991 (DB OVM dom0)

MOS Note 2348948.1

Updates to 12.2.1.1.5:

  • No new firmware updates additional to 12.2.1.1.5
12.2.1.1.5 January 4, 2018

27203983 (Cell)
27292320 (DB Linux and OVM domU)
27292321 (DB OVM dom0)

MOS Note 2341587.1

Updates to 12.2.1.1.4:

  • No new firmware updates additional to 12.2.1.1.4
12.2.1.1.4 November 22, 2017

(Re-issued November 28, 2017)

27032747 (Cell)
27103625 (DB Linux and OVM domU)
27103627 (DB OVM dom0)

MOS Note 2324367.1

Updates to 12.2.1.1.3:

  • No new firmware updates additional to 12.2.1.1.3
12.2.1.1.3 October 25, 2017

26671200 (Cell)
26774227 (DB Linux and OVM domU)
26774228 (DB OVM dom0)

MOS Note 2300276.1

Updates to 12.2.1.1.2:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW 1.9.0
    ILOM 3.2.10.24
    BIOS 08.14.01.13
12.2.1.1.2 July 2017

26027495 (Cell)
26151721 (DB Linux and OVM domU)
26151722 (DB OVM dom0)

MOS Note 2270791.1

Support for new 8TB disk model FRU.

Updates to 12.2.1.1.1:

  • Disks -
    Hitachi 8TB SAS - A374 (H7280B520 model)

12.2.1.1.1 April 2017

25512521 (Cell)
25640941 (DB Linux and OVM domU)
25640948 (DB OVM dom0)

MOS Note 2231247.1

Updates to 12.2.1.1.0:

  • Disks -
    Hitachi 8TB SAS - PAG1 (H7280A520 model)

12.2.1.1.0 January 2017

21052028 (Cell)
25463013 (DB Linux and OVM domU)
25463019 (DB OVM dom0)

MOS Note 2207148.1

New major feature image release with feature support for Oracle Database 12.2c Release 2.

Updates to 12.1.2.3.4:

  • No new firmware updates additional to 12.1.2.3.4
12.1.2.3.7 October 25, 2017

26739595 (Cell)
26774178 (DB Linux and OVM domU)
26774179 (DB OVM dom0)

MOS Note 2305709.1

Updates to 12.1.2.3.6:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW 1.9.0
    ILOM 3.2.10.24
    BIOS 08.14.01.13
12.1.2.3.6 July 2017

26027499 (Cell)
26151718 (DB Linux and OVM domU)
26151719 (DB OVM dom0)

MOS Note 2270790.1

Support for new 8TB disk model FRU.

Updates to 12.1.2.3.5:

  • Disks -
    Hitachi 8TB SAS - A374 (H7280B520 model)

12.1.2.3.5 April 2017

25509078 (Cell)
25640844 (DB Linux and OVM domU)
25640846 (DB OVM dom0)

MOS Note 2231245.1

Updates to 12.1.2.3.4:

  • Disks -
    Hitachi 8TB SAS - PAG1 (H7280A520 model)

12.1.2.3.4 January 2017

25031476 (Cell)
25093501 (DB Linux and OVM domU)
25093502 (DB OVM dom0)

MOS Note 2203610.1

Updates to 12.1.2.3.3:

  • No new firmware updates additional to 12.1.2.3.3
12.1.2.3.3 December 2016 (161208 label)

November 2016 (161109 label)

October 2016 (161013 label)

24441458 (Cell)
24669306 (DB Linux and OVM domU)
24669307 (DB OVM dom0)

MOS Note 2181366.1

*** 12.1.2.3.3 was re-spun and re-released in November, primarily for security bug fixes. This was re-spun again in December, not adding any additional firmware. There are no firmware updates specifically for V2/X2-2/X2-8. The specific bug fix list is contained in the README for Patch 24441458. 

Updates to 12.1.2.3.2:

  • DB X4170M2 (DB) & Cell x4270m2 SW 1.8.0
    ILOM 3.2.7.30.a
    BIOS 08.14.01.12
  • Disks -
    Hitachi 600GB SAS - A8C0
12.1.2.3.2 July 2016

23200959 (Cell)
23564643 (DB Linux and OVM domU)
23564644 (DB OVM dom0)

MOS Note 2133207.1

 

Updates to 12.1.2.3.1:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW 1.7.7
    ILOM 3.1.2.54
    BIOS 08.14.01.11
  • Disks -
    Hitachi 8TB SAS - P9E2 (H7280A520 model)
    Hitachi 4TB SAS - A3A0
    Hitachi 600GB SAS - A820
12.1.2.3.1 April 2016
(Cell image re-issued July 2016)

24306177 (Cell)
22954700 (DB Linux and OVM domU)
22954703 (DB OVM dom0)

MOS Note 2124734.1

Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.

Updates to 12.1.2.3.0:

  • Disks - 
    Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
One-off MLR patches

March 2016

(Withdrawn July 2016)

WITHDRAWN - Refer to MOS Note 2073916.1 for details.

One-off MLR patches for various image releases to address Exadata Critical Issues 1270094.1 EX25 (and EX28). EX28 is not specifically applicable to X2-8, however the EX25 firmware is bundled in the same patch.

The patches will update the cell and cell rpm version date string (not the image version number or date) and will also update the firmware bundle file and CheckHWnFWProfile check scripts within the image.

These patches were withdrawn in July 2016 due to EX29.

Updates to 12.1.2.2.0, 12.1.2.2.1, 12.1.2.3.0:

  • Disks -
    Hitachi 600GB SAS - A880 (Withdrawn)
12.1.2.3.0 February 2016

21749993 (Cell)
22750145 (DB Linux and OVM domU)
22750142 (DB OVM dom0)

MOS Note 2049743.1

 

  • LSI HBA firmware package - 12.12.0-0243
  • Disks - 
    Hitachi 8TB SAS - P901 (H7280A520 model)
    Hitachi 600GB SAS - A820
12.1.2.2.3 July 2016

23217781 (Cell)
23557378 (DB Linux and OVM domU)
23557379 (DB OVM dom0)

MOS Note 2133208.1

 

Updates to 12.1.2.2.2:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW 1.7.7
    ILOM 3.1.2.54
    BIOS 08.14.01.11
  • Disks - 
    Hitachi 8TB SAS - P9E2 (H7280A520 model)
    Hitachi 4TB SAS - A3A0
    Hitachi 600GB SAS - A820
12.1.2.2.2 April 2016
(Cell image re-issued in July 2016)

24306258 (Cell)
22929395 (DB Linux and OVM domU)
22929396 (DB OVM dom0)

MOS Note 2124710.1

Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.

Updates to 12.1.2.2.1:

  • Disks - 
    Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
12.1.2.2.1 January 2016

22106928 (Cell)
22277123 (DB Linux and OVM domU)
22277124 (DB OVM dom0)

MOS Note 2094446.1

 

Updates to 12.1.2.2.0:

  • No new firmware updates additional to 12.1.2.2.0
12.1.2.2.0 September 2015

20131726 (Cell)
21825906 (DB Linux and OVM domU)
21825879 (DB OVM dom0)

MOS Note 2038073.1

Includes support for 8TB disks, IPv6, ExaCLI utility, patchmgr use for DB node updates.

  • DB X4170M2 (DB) & X4270M2 (Cell) SW1.7.5
    ILOM 3.1.2.20.g
    BIOS 08.14.01.09
  • LSI HBA firmware package - 12.12.0-0229
  • Disks - 
    Hitachi 8TB SAS - P554 (H7280A520 model)
    Hitachi 600GB SAS - A7E0
12.1.2.1.3 October 2015

21446295 (Cell)
21821557 (DB Linux and OVM domU)
21821610 (DB OVM dom0)

MOS Note 2031447.1

ILOM security fixes.

Updates to 12.1.2.1.2:

  • DB X4170M2 (DB) & X4270M2 (Cell) SW1.7.5
    ILOM 3.1.2.20.g
    BIOS 08.14.01.09
12.1.2.1.2 June 2015

20748218  (Cell)
21151982 (DB Linux)
21151986 (DB OVM)
16486998 (Latest dbnodeupdate.sh)

MOS Note 2014306.1

Updates to 12.1.2.1.1:

  • No new firmware updates additional to 12.1.2.1.0
12.1.2.1.1 (12c) March 2015 20240049 (Cell)
20746761 (DB ULN)
16486998 (Latest dbnodeupdate.sh)

MOS Note 1959143.1

 

Updates to 12.1.2.1.0:

  • No new firmware updates additional to 12.1.2.1.0
12.1.2.1.0 (12c) December 2014 17885582 (Cell)
20170913 (DB ULN)
16486998 (Latest dbnodeupdate.sh)

MOS Note 1947476.1

 

  • X4170M2 (DB) & X4270M2 (Cell) SW1.7.3.1
    ILOM 3.1.2.20.e
    BIOS 08.14.01.05
  • IB HCA 2.11.2012
  • Disks -
    Hitachi 600GB SAS - A7A0
    Hitachi 4TB SAS - A2D2
    Hitachi 3TB SAS - A6C0
    Hitachi 2TB SAS - A6C0
12.1.1.1.2 (12c) April 2015 20699031

MOS Note 1995937.1

 

Updates to 12.1.1.1.1:

  • Disks - 
    Hitachi 4TB SAS - A2D2
    Hitachi 3TB SAS - A6C0
    Hitachi 2TB SAS - A6C0
    Hitachi 600GB SAS - A7A0
12.1.1.1.1 (12c) July 2014 18084575

MOS Note 1667407.1

Includes support for 4TB SAS disk upgrades to X2-2 Storage Servers.

  • X4170M2 (DB) & X4270M2 (Cell) SW1.7.3
    ILOM 3.1.2.20.c
    BIOS 08.14.01.05
  • Flash F20 / F20 M2 - LSI 1.27.96
  • Disks - 
    Hitachi 4TB SAS - A260
    Hitachi 3TB SAS - A690
    Hitachi 2TB SAS - A690
12.1.1.1.0 (12c)  December 2013 16980054 (Cell)
17997668 (DB)

MOS Note 1571789.1

Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.

Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).

Note: 12.1.1.1.0 provides additional features for customers running Oracle 12c database, and would be optionally installed to replace 11.2.x.x.x. This was released concurrently with 11.2.3.3.0.

  • X4170M2 (DB) & X4270M2 (Cell) SW1.7.2
    ILOM 3.1.2.20.b
    BIOS 08.14.01.03 
  • IB HCA 2.11.2010
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
11.2.3.3.1 (11g) June 2014 19166601 (Cell)
18876946 (DB ULN)

MOS Note 1667414.1

Incorporates the latest available firmware for all hardware, including firmware updates.

Includes support for 4TB SAS disk upgrades to X2-2 Storage Servers.

  • X4170M2 (DB) & X4270M2 (Cell) SW1.7.3
    ILOM 3.1.2.20.c
    BIOS 08.14.01.05
  • Flash F20 / F20 M2 - LSI 1.27.96
  • Disks - 
    Hitachi 4TB SAS - A260
    Hitachi 3TB SAS - A690
    Hitachi 2TB SAS - A690
11.2.3.3.0 (11g) December 2013 16278923 (Cell)
17809253 (DB)

MOS Note 1487339.1

Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.

Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).

Note: 11.2.3.3.0 was the default version intended for customers running Oracle 11g database. 12.1.1.1.0 was released concurrently and provides additional features for customers running Oracle 12c database.

  • X4170M2 (DB) & X4270M2 (Cell) SW1.7.2
    ILOM 3.1.2.20.b
    BIOS 08.14.01.03 
  • IB HCA 2.11.2010
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
11.2.3.2.2 March 2014 17953347 (Cell)
18205376 (DB)

MOS Note 1608581.1

Incorporates major firmware updates and several other critical fixes previously in various MLR patches.

  • IB HCA 2.11.2010
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 - LSI 1.27.95
  • Flash F20 M2 - LSI 1.27.95
  • Disks -
    Hitachi 3TB SAS - A600
    Hitachi 2TB SAS - A600
    Hitachi 600GB SAS - A780
One-off MLR patch March 2014 17878822

Standalone patch for LSI firmware to address 'chip pause' issue.  Applies to 11.2.3.2.1 image only, and does not update the image version, just the firmware.

  • LSI HBA firmware package - 12.12.0-0178
One-off MLR patches July - Dec 2013 17201499
<WITHDRAWN>

[WITHDRAWN: Do not use due to Flash firmware 1.27.94 issues]

Standalone patch for critical software and firmware bug fixes.  Updates software RPMs, Aura card firmware, and LSI firmware.  Applies to 11.2.3.2.1 image only, and does not update the image version, just the RPMs, and firmware.  

Note: CheckHWnFWProfile script does not get updated.

  • LSI HBA firmware package - 12.12.0-0172
  • Flash F20 / F20 M2 - LSI 1.27.94
11.2.3.2.1 January 2013 14522699 (Cell)
16432033 (DB)

MOS Note 1485475.1

Incorporates the firmware updates previously in the one-off firmware-only patch.

Option to prevent database server hot spare disk reclaim.

ILOM Memory Leak and PCI Riser BIOS fixes.

  • X4170M2 (DB) & X4270M2 (Cell) SW 1.6.1
    ILOM 3.0.16.10.d
    BIOS 08.12.01.04
  • LSI HBA firmware package - 12.12.0-0140
  • Flash F20 / F20 M2 - FMOD D21Y
  • Disks -
    Hitachi 3TB SAS - A310
    Hitachi 2TB SAS - A310
    Hitachi 600GB SAS - A700
One-off Firmware November 2012 14793859

Standalone patch for ILOM and Flash MOD firmware. Applies to any older image, and does not update the image version, just the firmware and CheckHWnFWProfile script.

MOS Note 1504776.1

  • X4170M2 (DB) & X4270M2 (Cell) SW1.6.1
    ILOM 3.0.16.10.d
    BIOS 08.12.01.04
  • Flash F20 / F20 M2 - FMOD D21Y
11.2.3.2.0 September 2012 14212264

MOS Note 1468877.1

Write-back Smart Flash Cache

Linux OEL UEK Kernel is now the default.

Solaris 11 SRU8.5.

  • Disks -
    Seagate 600GB SAS - 0B25
11.2.3.1.1 June 2012 13998727

MOS Note 1466459.1

  • No new firmware updates additional to 11.2.3.1.0
11.2.3.1.0 March 2012 13536739 MOS Note 1429907.1

Solaris 11 support for  FCS version plus SRU2 plus IDR's.

OEL 5.7. Linux OS updates now provided via ULN
  • LSI HBA firmware package - 12.12.0-0079
  • Disks -
    Seagate 600GB SAS - 0A25; Hitachi 600GB SAS - A6C0
11.2.2.4.2 December 2011 13513611 MOS Note 1388400.1

Support for 3TB SAS disks in Storage Cells

Patches for 10GbE issue, ntpd and flash drives no longer accessible after 6 months uptime.
  • Disks -
    Seagate 3TB SAS - 064A; Hitachi 3TB SAS - A142
11.2.2.4.1 December 2011 13444164 MOS Note 1381730.1

Support for mixed drive vendor support in Storage Cells
  • Disks -
    Hitachi 600GB SAS - A5C8
    Hitachi 2TB SAS - A142
11.2.2.4.0 October 2011 12708838 MOS Note 1348647.1

Solaris 11 Express SRU10 update; and Smart Flash Cache and Flash Log features added
  • X4170M2 (DB) & X4270M2 (Cell) SW1.4
    ILOM 3.0.16.10
    BIOS 08.08.01.02
  • Disks -
    Seagate 2TB SAS - 061A
11.2.2.3.5 August 2011 12849110 MOS Note 1334254.1

Patch release with new IB OFED stack that fixes a kernel panic on db nodes
  • No new firmware updates additional to 11.2.2.3.2
11.2.2.3.3 July 2011 Factory only release New verify-topology to support storage expansion racks
  • No new firmware updates additional to 11.2.2.3.2
11.2.2.3.2 May 2011 12577723 MOS Note 1323958.1

New major release with dual-boot image support Solaris on DB nodes option during install.  OFED stack updated.

Support for Flash Aura 1.1 card.
  • X4170M2 (DB) & X4270M2 (Cell) SW1.3
    ILOM 3.0.14.11.b
    BIOS 08.06.01.08
  • IB HCA 2.7.81.30
  • LSI HBA firmware package - 12.12.0-0048
  • Flash F20 - LSI 1.27.92 FMOD D20Y
11.2.2.2.2 March 2011 11721471 MOS Note 1292030.1

kernel patch update for db and cell base image
  • No new firmware updates additional to 11.2.2.2.0
11.2.2.2.0 December 13, 2010 10356485 MOS Note 1270634.1

New major release, OFED 1.5.1 release, contains OS workaround for DIMM C-state issue
  • Disks -
    Seagate 600GB SAS 0805;
    Seagate 2TB SAS 0514
  • Flash F20 - LSI 1.27.91 FMOD D20Y
11.2.2.1.1 November 2010 10248893 MOS Note 1215784.1

LSI SAS HBA firmware update
  • LSI HBA firmware package 12.9.0-0049
11.2.2.1.0 October 20, 2010 Original Factory Release OEL5.5, Oracle DB 11.2.0.2
  • X4170M2 (DB) & X4270M2 (Cell) SW1.3
    ILOM 3.0.9.27.a
    BIOS 08.04.02.03
  • IB HCA 2.7.81.00
  • LSI HBA firmware package - 12.9.0-0037
  • Disks -
    Seagate 600GB SAS 0705;
    Seagate 2TB SAS 0414
  • Flash F20 - LSI 1.27.90 FMOD D20Y

[go to top]

Exadata OS/Firmware Image History for V2

VersionRelease DatePatch DownloadsDetail NotesFirmware versions included
18.1.5.0.0 May 9, 2018

27503194 (Cell)
27561908 (DB Linux and OVM domU)
27561909 (DB OVM dom0)

MOS Note 2362411.1

Includes Critical Linux and Xen security fixes which includes fixes for CVE-2017-5715 (Spectre Variant 2), Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754).

Updates to 18.1.4.0.0:

  • DB X4170 (DB) & X4275 (Cell) SW 2.8.0
    ILOM 3.2.11.20.a
    BIOS 07.06.03.19
18.1.4.0.0 February 1, 2018

27347059 (Cell)
27391002 (DB Linux and OVM domU)
27391003 (DB OVM dom0)

MOS Note 2348949.1

Updates to 18.1.3.0.0:

  • No new firmware updates additional to 18.1.3.0.0
18.1.3.0.0 January 4, 2018

27203979 (Cell)
27292339 (DB Linux and OVM domU)
27292341 (DB OVM dom0)

MOS Note 2341600.1

Updates to 18.1.2.0.0:

  • No new firmware updates additional to 18.1.2.0.0
18.1.2.0.0 November 22, 2017

(Re-issued November 29, 2017)

27062341 (Cell)
27103628 (DB Linux and OVM domU)
27103629 (DB OVM dom0)

MOS Note 2324358.1

Updates to 18.1.1.0.0:

  • No new firmware updates additional to 18.1.1.0.0
18.1.1.0.0 October 25, 2017

26875767 (Cell)
26923500 (DB Linux and OVM domU)
26923501 (DB OVM dom0)

MOS Note 2311786.1

Updates to 18.1.0.0.0:

  • DB X4170 (DB) & X4275 (Cell) SW 2.7.0
    ILOM 3.2.10.24
    BIOS 07.06.03.18
18.1.0.0.0 October 3, 2017

25342756 (Cell)
26829586 (DB Linux and OVM domU)
26829591 (DB OVM dom0)

MOS Note 2288392.1

New major feature image release with feature support for Oracle Database 18c with new version numbering scheme based on year of release similar to Oracle Database.

Updates to 12.2.1.1.2:

  • No new firmware updates additional to 12.1.2.3.4 and 12.2.1.1.0.

12.2.1.1.7 May 9, 2018

27503198 (Cell)
27561867 (DB Linux and OVM domU)
27561868 (DB OVM dom0)

MOS Note 2362410.1

Includes Critical Linux and Xen security fixes which includes fixes for CVE-2017-5715 (Spectre Variant 2), Spectre Variant 1 (CVE-2017-5753) and Meltdown (CVE-2017-5754).

Updates to 12.2.1.1.6:

  • DB X4170 (DB) & X4275 (Cell) SW 2.8.0
    ILOM 3.2.11.20.a
    BIOS 07.06.03.19
12.2.1.1.6 February 1, 2018

27351065 (Cell)
27390990 (DB Linux and OVM domU)
27390991 (DB OVM dom0)

MOS Note 2348948.1

Updates to 12.2.1.1.5:

  • No new firmware updates additional to 12.2.1.1.5
12.2.1.1.5 January 4, 2018

27203983 (Cell)
27292320 (DB Linux and OVM domU)
27292321 (DB OVM dom0)

MOS Note 2341587.1

Updates to 12.2.1.1.4:

  • No new firmware updates additional to 12.2.1.1.4
12.2.1.1.4 November 22, 2017

(Re-issued November 28, 2017)

27032747 (Cell)
27103625 (DB Linux and OVM domU)
27103627 (DB OVM dom0)

MOS Note 2324367.1

Updates to 12.2.1.1.3:

  • No new firmware updates additional to 12.2.1.1.3
12.2.1.1.3 October 25, 2017

26671200 (Cell)
26774227 (DB Linux and OVM domU)
26774228 (DB OVM dom0)

MOS Note 2300276.1

Updates to 12.2.1.1.2:

  • DB X4170 (DB) & X4275 (Cell) SW 2.7.0
    ILOM 3.2.10.24
    BIOS 07.06.03.18
12.2.1.1.2 July 2017

26027495 (Cell)
26151721 (DB Linux and OVM domU)
26151722 (DB OVM dom0)

MOS Note 2270791.1

Updates to 12.2.1.1.1:

  • No new firmware updates additional to 12.1.2.3.4 and 12.2.1.1.0.

12.2.1.1.1 April 2017

25512521 (Cell)
25640941 (DB Linux and OVM domU)
25640948 (DB OVM dom0)

MOS Note 2231247.1

Updates to 12.2.1.1.0:

  • No new firmware updates additional to 12.1.2.3.4 and 12.2.1.1.0.

12.2.1.1.0 January 2017

21052028 (Cell)
25463013 (DB Linux and OVM domU)
25463019 (DB OVM dom0)

MOS Note 2207148.1

New major feature image release with feature support for Oracle Database 12.2c Release 2.

Updates to 12.1.2.3.4:

  • No new firmware updates additional to 12.1.2.3.4
12.1.2.3.7 October 25, 2017

26739595 (Cell)
26774178 (DB Linux and OVM domU)
26774179 (DB OVM dom0)

MOS Note 2305709.1

Updates to 12.1.2.3.6:

  • DB X4170 (DB) & X4275 (Cell) SW 2.7.0
    ILOM 3.2.10.24
    BIOS 07.06.03.18
12.1.2.3.6 July 2017

26027499 (Cell)
26151718 (DB Linux and OVM domU)
26151719 (DB OVM dom0)

MOS Note 2270790.1

Updates to 12.1.2.3.5:

  • No new firmware updates additional to 12.1.2.3.4

12.1.2.3.5 April 2017

25509078 (Cell)
25640844 (DB Linux and OVM domU)
25640846 (DB OVM dom0)

MOS Note 2231245.1

Updates to 12.1.2.3.4:

  • No new firmware updates additional to 12.1.2.3.4

12.1.2.3.4 January 2017

25031476 (Cell)
25093501 (DB Linux and OVM domU)
25093502 (DB OVM dom0)

MOS Note 2203610.1

Updates to 12.1.2.3.3:

  • No new firmware updates additional to 12.1.2.3.3
12.1.2.3.3 December 2016 (161208 label)

November 2016 (161109 label)

October 2016 (161013 label)

24441458 (Cell)
24669306 (DB Linux and OVM domU)
24669307 (DB OVM dom0)

MOS Note 2181366.1

*** 12.1.2.3.3 was re-spun and re-released in November, primarily for security bug fixes. This was re-spun again in December, not adding any additional firmware. There are no firmware updates specifically for V2/X2-2/X2-8. The specific bug fix list is contained in the README for Patch 24441458. 

Updates to 12.1.2.3.2:

  • DB X4170 (DB) & X4275 (Cell) SW 2.6.10
    ILOM 3.0.16.38.a
    BIOS 07.06.03.15
  • Disks -
    Hitachi 600GB SAS - A8C0
12.1.2.3.2 July 2016

23200959 (Cell)
23564643 (DB Linux and OVM domU)
23564644 (DB OVM dom0)

MOS Note 2133207.1

 

Updates to 12.1.2.3.1:

  • DB X4170 (DB) & X4275 (Cell) SW 2.6.9
    ILOM 3.0.16.38
    BIOS 07.06.03.15
  • Disks -
    Hitachi 600GB SAS - A820
12.1.2.3.1 April 2016
(Cell image re-issued July 2016)

24306177 (Cell)
22954700 (DB Linux and OVM domU)
22954703 (DB OVM dom0)

MOS Note 2124734.1

Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.

Updates to 12.1.2.3.0:

  • Disks - 
    Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
One-off MLR patches

March 2016

(Withdrawn July 2016)

WITHDRAWN - Refer to MOS Note 2073916.1 for details.

One-off MLR patches for various image releases to address Exadata Critical Issues 1270094.1 EX25 (and EX28). EX28 is not specifically applicable to X2-8, however the EX25 firmware is bundled in the same patch.

The patches will update the cell and cell rpm version date string (not the image version number or date) and will also update the firmware bundle file and CheckHWnFWProfile check scripts within the image.

These patches were withdrawn in July 2016 due to EX29.

Updates to 12.1.2.2.0, 12.1.2.2.1, 12.1.2.3.0:

  • Disks -
    Hitachi 600GB SAS - A880 (Withdrawn)
12.1.2.3.0 February 2016

21749993 (Cell)
22750145 (DB Linux and OVM domU)
22750142 (DB OVM dom0)

MOS Note 2049743.1

 

  • LSI HBA firmware package - 12.12.0-0243
  • Disks -
    Hitachi 600GB SAS - A820
12.1.2.2.3 July 2016

23217781 (Cell)
23557378 (DB Linux and OVM domU)
23557379 (DB OVM dom0)

MOS Note 2133208.1

 

Updates to 12.1.2.2.2:

  • DB X4170 (DB) & X4275 (Cell) SW 2.6.9
    ILOM 3.0.16.38
    BIOS 07.06.03.15
  • Disks - 
    Hitachi 600GB SAS - A820
12.1.2.2.2 April 2016
(Cell image re-issued in July 2016)

24306258 (Cell)
22929395 (DB Linux and OVM domU)
22929396 (DB OVM dom0)

MOS Note 2124710.1

Note: Cell image was re-issued in July 2016 to remove Hitachi 600GB SAS firmware A880 - see Critical Issues 1270094.1 EX29 for details.

Updates to 12.1.2.2.1:

  • Disks - 
    Hitachi 600GB SAS - A820 (Replaced A880 in re-issue)
12.1.2.2.1 January 2016

22106928 (Cell)
22277123 (DB Linux and OVM domU)
22277124 (DB OVM dom0)

MOS Note 2094446.1

 

Updates to 12.1.2.2.0:

  • No new firmware updates additional to 12.1.2.2.0
12.1.2.2.0 September 2015

20131726 (Cell)
21825906 (DB Linux and OVM domU)
21825879 (DB OVM dom0)

MOS Note 2038073.1

Includes support for  IPv6, ExaCLI utility, patchmgr use for DB node updates.

  • DB X4170 (DB) & X4275 (Cell) SW2.6.7
    ILOM 3.0.16.15.j
    BIOS 07.06.03.13
  • LSI HBA firmware package - 12.12.0-0229
  • Disks - 
    Hitachi 600GB SAS - A7E0
12.1.2.1.3 October 2015

21446295 (Cell)
21821557 (DB Linux and OVM domU)
21821610 (DB OVM dom0)

MOS Note 2031447.1

ILOM security fixes.

 Updates to 12.1.2.1.2:

  • DB X4170 (DB) & X4275 (Cell) SW2.6.7
    ILOM 3.0.16.15.j
    BIOS 07.06.03.13
12.1.2.1.2 June 2015

20748218  (Cell)
21151982 (DB Linux)
21151986 (DB OVM)
16486998 (Latest dbnodeupdate.sh)

MOS Note 2014306.1

 Updates to 12.1.2.1.1:

  • No new firmware updates additional to 12.1.2.1.0
12.1.2.1.1 (12c) March 2015 20240049 (Cell)
20746761 (DB ULN)
16486998 (Latest dbnodeupdate.sh)

MOS Note 1959143.1

 

 Updates to 12.1.2.1.0:
  • No new firmware updates additional to 12.1.2.1.0
12.1.2.1.0 (12c) December 2014 17885582 (Cell)
20170913 (DB ULN)
16486998 (Latest dbnodeupdate.sh)

MOS Note 1947476.1

  • X4170 (DB) & X4275 (Cell) SW2.6.5.1
    ILOM 3.0.16.15.h
    BIOS 07.06.03.10
  • Disks -
    Hitachi 600GB SAS - A7A0
12.1.1.1.2 (12c) April 2015 20699031

MOS Note 1995937.1

 

 Updates to 12.1.1.1.1:

  • Disks -
    Hitachi 600GB SAS - A7A0
12.1.1.1.1 (12c) July 2014 18084575

MOS Note 1667407.1

  • X4170 (DB) & X4275 (Cell) SW2.6.5
    ILOM 3.0.16.15.e
    BIOS 07.06.03.10
  • Flash F20 / F20 M2 - LSI 1.27.96
12.1.1.1.0 (12c)  December 2013 16980054 (Cell)
17997668 (DB)

MOS Note 1571789.1

Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.

Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).

Note: 12.1.1.1.0 provides additional features for customers running Oracle 12c database, and would be optionally installed to replace 11.2.x.x.x. This was released concurrently with 11.2.3.3.0.

  • X4170 (DB) & X4275 (Cell) SW2.6.4
    ILOM 3.0.16.15.d
    BIOS 07.06.03.09
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
11.2.3.3.1 (11g) June 2014 19166601 (Cell)
18876946 (DB ULN)

MOS Note 1667414.1

 

  • X4170 (DB) & X4275 (Cell) SW2.6.5
    ILOM 3.0.16.15.e
    BIOS 07.06.03.10
  • Flash F20 / F20 M2 - LSI 1.27.96
11.2.3.3.0 (11g) December 2013 16278923 (Cell)
17809253 (DB)

MOS Note 1487339.1

Incorporates the latest available firmware for all hardware, including firmware updates previously in the one-off firmware-only patch.

Also includes firmware and script tool to patch update InfiniBand switches over the network (not automatic).

Note: 11.2.3.3.0 was the default version intended for customers running Oracle 11g database. 12.1.1.1.0 was released concurrently and provides additional features for customers running Oracle 12c database.

  • X4170 (DB) & X4275 (Cell) SW2.6.4
    ILOM 3.0.16.15.d
    BIOS 07.06.03.09
  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
11.2.3.2.2 March 2014 17953347 (Cell)
18205376 (DB)

MOS Note 1608581.1

Incorporates major firmware updates and several other critical fixes previously in various MLR patches.

  • LSI HBA firmware package - 12.12.0-0178
  • Flash F20 / F20 M2 - LSI 1.27.95
  • Disks -
    Hitachi 600GB SAS - A780
One-off MLR patch March 2014 17878822

Standalone patch for LSI firmware to address 'chip pause' issue.  Applies to 11.2.3.2.1 image only, and does not update the image version, just the firmware.

  • LSI HBA firmware package - 12.12.0-0178
One-off MLR patches July - Dec 2013

17201499
<WITHDRAWN>

[WITHDRAWN: Do not use due to Flash firmware 1.27.94 issues.]

Standalone patch for critical software and firmware bug fixes.  Updates software RPMs, Aura card firmware, and LSI firmware.  Applies to 11.2.3.2.1 image only, and does not update the image version, just the RPMs, and firmware.  

Note: CheckHWnFWProfile script does not get updated.

  • LSI HBA firmware package - 12.12.0-0172
  • Flash F20 / F20 M2 - LSI 1.27.94
11.2.3.2.1 January 2013 14522699 (Cell)
16432033 (DB)

MOS Note 1485475.1

Incorporates the firmware updates previously in the one-off firmware-only patch.

Option to prevent database server hot spare disk reclaim.

ILOM Memory Leak and PCI Riser BIOS fixes.

  • X4170 (DB) & X4275 (Cell) SW 2.6.1
    ILOM 3.0.16.15.a
    BIOS 07.06.03.04
  • LSI HBA firmware package - 12.12.0-0140
  • Flash F20 / F20 M2 - FMOD D21Y
One-off Firmware November 2012 14793859

Standalone patch for Flash MOD firmware. Applies to any older image, and does not update the image version, just the firmware and CheckHWnFWProfile script.

MOS Note 1504776.1

  • Flash F20 / F20 M2 - FMOD D21Y
11.2.3.2.0 September 2012 14212264

MOS Note 1468877.1

Write-back Smart Flash Cache

Linux OEL UEK Kernel is now the default.

  • Disks -
    Seagate 600GB SAS - 0B25
11.2.3.1.1 June 2012 13998727 MOS Note 1466459.1
  • No new firmware updates additional to 11.2.3.1.0
11.2.3.1.0 March 2012 13536739 MOS Note 1429907.1

OEL 5.7. Linux OS updates now provided via ULN
  • LSI HBA firmware package - 12.12.0-0079
  • Disks -
    Seagate 600GB SAS - 0A25; Hitachi 600GB SAS - A6C0
11.2.2.4.2 December 2011 13513611 MOS Note 1388400.1

Patches for 10GbE issue, ntpd and flash drives no longer accessible after 6 months uptime.
  • No new firmware updates additional to 11.2.2.3.5
11.2.2.4.1 December 2011 13444164 MOS Note 1381730.1

Support for mixed drive vendor support in Storage Cells
  • No new firmware updates additional to 11.2.2.3.5
11.2.2.4.0 October 2011 12708838 MOS Note 1348647.1

Smart Flash Cache and Flash Log features added
  • No new firmware updates additional to 11.2.2.3.5
11.2.2.3.5 August 2011 12849110 MOS Note 1334254.1

Patch release with new IB OFED stack that fixes a kernel panic on db nodes; new BIOS to fix PCIe Gen2 regression introduced in 11.2.2.3.2
  • X4170 (DB) & X4275 (Cell) SW 2.5.1
    ILOM 3.0.9.19.e
    BIOS 07.06.02.32
11.2.2.3.3 July 2011 Factory only release New verify-topology to support storage expansion racks
  • No new firmware updates additional to 11.2.2.3.2
11.2.2.3.2 May 2011 12577723 MOS Note 1323958.1

OFED stack updated.

Support for Flash Aura 1.1 card.

NOTE: Solaris and dual-boot is NOT supported on V2 x4170 DB nodes.
  • X4170 (DB) & X4275 (Cell) SW2.5
    ILOM 3.0.9.19.c
    BIOS 07.06.02.30
  • LSI HBA firmware package - 12.12.0-0048
  • Flash F20 - LSI 1.27.92 FMOD D20Y
11.2.2.2.2 March 2011 11721471
MOS Note 1292030.1

Kernel patch update for db and cell base image
  • No new firmware updates additional to 11.2.2.2.0
11.2.2.2.0 December 2010 10356485 MOS Note 1270634.1

New major kernel and OFED 1.5.1 release
  • Disks -
    Seagate 600GB SAS 0805;
  • Flash F20 - LSI 1.27.91 FMOD D20Y
11.2.2.1.1 November 2010 10248893 MOS Note 1215784.1

Oracle DB 11.2.0.2

LSI SAS HBA firmware update
  • LSI HBA firmware package - 12.9.0-0049
  • Flash F20 - LSI 1.27.90 FMOD D20Y
11.2.1.3.1 August 2010 9969888 MOS Note 1166560.1

New major OEL 5.5 release for new image installs; OEL 5.3 updates for patch only.

ILOM fixes for most common memory leak bugs and improved fan control for DB nodes

Seagate 600GB SAS firmware fix for calibrate issue
  • X4170 (DB) & X4275 (Cell) SW2.3.1
    ILOM 3.0.9.19.a
    BIOS 07.06.02.23
  • Disks -
    Seagate 600GB SAS 0705
  • Flash F20 - LSI 1.27.90 FMOD D20R
11.2.1.3.0 June 2010 N/A Engineering trialed release at a few select customers which found issues. Not officially released.
11.2.1.2.6 May 2010 9592862 OEL 5.3 only patches release
  • No new firmware updates additional to 11.2.1.2.6
11.2.1.2.4 April 2010 9537568 DB node x4170 only patch release
  • No new firmware updates additional to 11.2.1.2.3
11.2.1.2.3 April 2010 9435285 Update image release to coincide with IB switch configuration changes
  • IB HCA 2.7.0.0
11.2.1.2.1 February 3, 2010 9307085 Update image release with ILOM fan control updates for Flash cards

All customer's were pro-actively updated to this version when it released
  • X4170 (DB) & X4275 (Cell) SW2.1B
    ILOM 3.0.6.10.b
    BIOS 07.06.02.19
  • LSI HBA firmware package - 12.0.1-0081
11.2.1.2.0 November 9, 2009 Original Factory Release OEL 5.3, Oracle DB 11.2.0.1
  • X4170 (DB) & X4275 (Cell) SW2.1A
    ILOM 3.0.6.10.a
    BIOS 07.06.02.15
  • IB HCA 2.6.0.0
  • LSI HBA firmware package - 12.0.0-0067
  • Disks -
    Seagate 600GB SAS 0605;
    Hitachi 2TB SATA A28A
  • Flash F20 - LSI 1.27.03 FMOD D20R

 [go to top]

 

Exadata - Sun Infiniband 36P Data Center Switch Firmware

Note: IB firmware provided with Exadata OS Image patch bundles can be installed using the bundled tools, independent of doing the whole OS Image update, so customer's can choose to qualify and update to the new IB firmware without updating the server's to the latest OS Image at the same time.

VersionRelease DatePatch DownloadsDetail Notes
2.2.9-3 May 9, 2018 27503194

Provided with Exadata OS Image 18.1.5.0.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.

2.2.7-1 Oct 2017 25342756

Provided with Exadata OS Image 18.1.0.0.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.

2.2.6-2 July 2017 26027495

Provided with Exadata OS Image 12.2.1.1.2 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.

2.2.5-3 April 2017 25512521

Provided with Exadata OS Image 12.2.1.1.1 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.

2.2.4-3 January 2017 21052028

Provided with Exadata OS Image 12.2.1.1.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.

2.1.8-1 February 2016 21749993

Provided with Exadata OS Image 12.1.2.3.0 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.

2.1.6-2 September 2015 20131726
or
21446295

Provided with Exadata OS Image 12.1.2.2.0 and 12.1.2.1.3 patch, installed via patchmgr from DB01 - Refer to patch README and Exadata documentation set for specific details.

2.1.5-2 December 2014 17885582

Provided with Exadata OS Image 12.1.2.1.0 patch, installed via patchmgr from DB01 - Refer to MOS Note 1947476.1 for specific details.

Requires switch to be on 2.1.3-4 or 1.3.3-2 before upgrading.

2.1.3-4 December 2013 16278923

Provided with Exadata OS Image 11.2.3.3.0 patch, installed via patchmgr from DB01 - Refer to MOS Note 1487339.1 for specific details.

ASR support and partitioning support with compatibility to Exalogic/BDA/SSC multi-racked environments (see MOS Note patch for caveats)

1.3.3-2 April 2011 12373676 (Exadata Scripts)
11891229 (Firmware package)
Resolves issues with the OFED stack that can cause the subnet manager to go offline and not failover which can bring down the IB fabric

Requires v1.1.3-2b to update using ILOM pkg format.
1.3.3-1 March 2011 Withdrawn Withdrawn due to a memory leak that could cause the switch to hang after 100 days
1.1.3-2 June 2010 9560930 Adds ILOM interface (web and cli) and "ilom-admin" user. Resolves potential switch hang and IB fabric loss of subnet manager issues, and several bugs.
1.0.1-1 November 2009 Original Factory Release None.

[go to top] 

Exadata - Sun Rack II Power Distribution Unit (PDU) Firmware

VersionRelease DatePatch DownloadsDetail Notes
1.0.6 January 2013 16523441

Resolves uptime and periodic resetting Bug 15807516 (Sun: 7188479).

Modifies default 'admin' password to meet Oracle password security requirements (change from 'admin' to 'adm1n')

1.0.4 August 2011 12871297 Provides the ability to reset to factory defaults with static IP 192.168.0.1 and all interfaces enabled. This is a fail safe if the customer inadvertently disables html and does not have snmp setup properly to reset it through that. The procedure is to hold down the button for 10-15 seconds until it starts counting down 5 4 3 2 1, then release the button, then while its still counting down, press and hold it down again for 20 seconds.
1.0.3 June 2011 12657995 Fixes the OID entity for SNMP (CR 7024526) to avoid issues with HP OpenView. Note this version was not tested against the Oracle EM plugins for Exadata.
1.0.2 September 2010 12691964 Changes the logo from Sun to Oracle.

Adds the ability to do SNMP v1 and v2 traps, for integration with Oracle EM plugins for Exadata. 

x2-2 shipped with this added the recommendation to connect them to the customer's management network during install.
1.0.1 November 2009 Original Factory Release

12657935
It is supported to downgrade if desired, but not recommended.

[go to top] 

Exadata - Cisco Catalyst 4948 / 4948EF Gigabit Ethernet Switch

The switch comes with Cisco Enterprise Support if under an Oracle Premier Support contract.  Support is
provided through Oracle TSC Network team with Cisco support agreements for further assistance from Cisco
if required. Oracle can provide patch updates to the Cisco Catalyst 4948 (WS-C4948-S) switch IOS firmware
if necessary.  The original version shipped was 12.2(46), however the version that Cisco currently ships may
be later than this.

The version of firmware shipped by Oracle on 4948 & 4948EF on Exadata X3-2/X3-8's is IPBASEK9 which does
include SSH support and is enabled by default out of the factory, with telnet disabled.

The version of firmware shipped by Oracle on Exadata V2 and X2-2/X2-8 4948's was the IPBASE and includes
telnet but does NOT include ssh support.  If the customer wishes to have SSH support, they can open an SR
with Oracle who will supply this and instructions per MOS Note 1415044.1

The version can be obtained using the "show version" command. 

burx2sw-ip>show version
Cisco IOS Software, Catalyst 4500 L3 Switch Software (cat4500-IPBASE-M),
Version 12.2(46)SG
, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2008 by Cisco Systems, Inc.
Compiled Fri 27-Jun-08 17:12 by prod_rel_team
Image text-base: 0x10000000, data-base: 0x1196D96C

ROM: 12.2(31r)SGA1
Dagobah Revision 226, Swamp Revision 5

burx2sw-ip uptime is 3 weeks, 1 day, 5 hours, 27 minutes
System returned to ROM by power-on
System restarted at 08:11:31 EST Mon Aug 29 2011
System image file is "bootflash:cat4500-ipbase-mz.122-46.SG.bin"

cisco WS-C4948 (MPC8245) processor (revision 0) with 262144K bytes of memory.
Processor board ID FOX1311GB53
MPC8245 CPU at 266Mhz, Fixed Module
Last reset from PowerUp
2 Virtual Ethernet interfaces
48 Gigabit Ethernet interfaces
511K bytes of non-volatile configuration memory.

Configuration register is 0x2101

burx2sw-ip>

 [go to top] 

Exadata - Avocent MergePoint Unity KVM Switch.

Oracle does not provide patch updates to the Avocent MergePoint Unit model MPU4032DAC KVM
switch firmware. Their is no specific qualification done of new versions. The original version shipped was
1.2.0, however the version that Avocent currently ships may be later than this and may be required based
on the internal switch processor being used in currently shipping switches.  It is not recommended to
downgrade, however it is recommended to upgrade for compatibility with newer Java and OS versions used
on the client accessing the switch. The USB dongles also contain a firmware and these are updated at the
same time as the switch is upgraded. For detailed upgrade instructions refer to the EIS checklist for
Exadata.  Avocent firmware updates may be obtained from Avocent's website.

[go to top]

 

References

<NOTE:2318642.1> - INTERNAL Exadata Database Machine Hardware Firmware and Patch History (X7-2, X7-8)
<NOTE:2088888.1> - How to Update Disk Drive Firmware on Exadata and Recovery Appliance Compute Nodes
<NOTE:1270094.1> - Exadata Critical Issues
<NOTE:888828.1> - Exadata Database Machine and Exadata Storage Server Supported Versions
<NOTE:1501410.1> - INTERNAL Exadata Database Machine Hardware Firmware and Patch History (X3-2, X4-2, X3-8, X4-8 w/X4-2L)
<NOTE:1998905.1> - INTERNAL Exadata Database Machine Hardware Firmware and Patch History (X5-2, X4-8 w/X5-2L, X5-8, X6-2, X6-8)

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback