Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1352363.1
Update Date:2018-01-08
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1352363.1 :   SPARC Enterprise T5x20 Device Paths  


Related Items
  • Sun SPARC Enterprise T5120 Server
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T5xx0
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>CMT Servers
  •  




Applies to:

Sun SPARC Enterprise T5120 Server - Version Not Applicable and later
Sun SPARC Enterprise T5220 Server - Version Not Applicable and later
Information in this document applies to any platform.

Purpose

This document lists the T5x20 device paths.

Details

PCI-E Slot 0    /pci@0/pci@0/pci@8/pci@0/pci@9   PCI-E x8P/x4E short
PCI-E Slot 1    /pci@0/pci@0/pci@8/pci@0/pci@1   PCI-E x8P/x4E short
PCI-E Slot 2    /pci@0/pci@0/pci@9               PCI-E x16P/x8E short
PCI-E Slot 3    /pci@0/pci@0/pci@8/pci@0/pci@a   PCI-E x8P/x4E short
PCI-E Slot 4    /pci@0/pci@0/pci@8/pci@0/pci@2   PCI-E x8P/x4E short
PCI-E Slot 5    /pci@0/pci@0/pci@8/pci@0/pci@8   PCI-E x8P/x8E short


Onboard gigabit interfaces:

Network 0    /pci@0/pci@0/pci@1/pci@0/pci@2/network@0
Network 1    /pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1 1
Network 2    /pci@0/pci@0/pci@1/pci@0/pci@3/network@0 2
Network 3    /pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1 3
		

Optional XAUI ports:

XAUI0        /niu@80/network/@0    <-- Uses PCIE-0 slot
XAUI1        /niu@80/network/@1    <-- Uses PCIE-1 slot 


PATA CDROM Drive (Huron 1 & 2):
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2/disk@0,0 

SATA CDROM Drive (Huron3):
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/hub@4/device@4/storage@0
	
USB0        /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@3  <-- Rear, Labeled as 0
USB1        /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@1  <-- Rear, Labeled as 1
USB2        /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/hub@4/storage@1  <-- Front, in DVD face, left port
USB3        /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/hub@4/storage@2  <-- Front, in DVD face, right port

====== Internal SAS disks: ======
Disk 0   /pci@0/pci@0/pci@2/scsi@0/sd@0,0
Disk 1   /pci@0/pci@0/pci@2/scsi@0/sd@1,0
Disk 2   /pci@0/pci@0/pci@2/scsi@0/sd@2,0
Disk 3   /pci@0/pci@0/pci@2/scsi@0/sd@3,0
Disk 4   /pci@0/pci@0/pci@2/scsi@0/sd@4,0
Disk 5   /pci@0/pci@0/pci@2/scsi@0/sd@5,0
Disk 6   /pci@0/pci@0/pci@2/scsi@0/sd@6,0
Disk 7   /pci@0/pci@0/pci@2/scsi@0/sd@7,0

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback