Asset ID: |
1-79-1220972.1 |
Update Date: | 2017-09-19 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1220972.1
:
PCIEX-8000-Q3 - PCI Express Subsystem Problem
Related Items |
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Sun Microsystems > Servers
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-4
Information in this document applies to any platform.
Purpose
Provide additional information for message ID: PCIEX-8000-Q3
Details
PCIEX subsytem problem
Type
- Fault
- fault.io.pciex.fw_mismatch
Severity
- Major
Description
- A firmware version mismatch was detected for a PCIEX device.
Automated Response
- One or more device instances may be disabled.
Impact
- Degraded services provided by the device instances associated with this fault.
Suggested Action for System Administrator
- Identify the device and then update the firmware to the latest version.
-
- Refer to the following document for the procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1. -
-
Details
- A firmware version mismatch was detected for a PCIEX device. Identify the device and use 'fwflash' to update the firmware to the latest version.
|