Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1220972.1
Update Date:2017-09-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1220972.1 :   PCIEX-8000-Q3 - PCI Express Subsystem Problem  


Related Items
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Sun Microsystems > Servers
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-4
Information in this document applies to any platform.

Purpose

Provide additional information for message ID: PCIEX-8000-Q3

Details

PCIEX subsytem problem

 

Type

Fault
   fault.io.pciex.fw_mismatch

Severity

Major

Description

A firmware version mismatch was detected for a PCIEX device.

Automated Response

One or more device instances may be disabled.

Impact

Degraded services provided by the device instances associated with this fault.

Suggested Action for System Administrator

Identify the device and then update the firmware to the latest version.
 
Refer to the following document for the procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1.
 
 

Details

A firmware version mismatch was detected for a PCIEX device.  Identify the device and use 'fwflash' to update the firmware to the latest version.