Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1220965.1
Update Date:2017-09-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1220965.1 :   PCI-8000-HR - PCI Subsystem Problem  


Related Items
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details


Applies to:

Sun Microsystems > Boards
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
Information in this document applies to any platform.

Purpose

Provide additional information for message ID:  PCI-8000-HR

Details

PCI subsytem problem

 

Type

Fault
  fault.io.pci.fw_corrupt

Severity

Major

Description

A firmware corruption was detected for a PCI device.

Automated Response

One or more device instances may be disabled.

Impact

Degraded services provided by the device instances associated with this fault.

Suggested Action for System Administrator

Use 'fmadm faulty' to identify the device and then update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.

Details

A firmware corruption was detected for a PCI device. Use 'fmadm faulty' to identify the device and use 'fwflash' to update the firmware to the latest version or schedule a repair procedure to replace the affected device. Contact Sun support for further information.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback