SPX86-8002-RY - Energy Storage Module is approaching end-of-life.
Related Items |
- Exadata Database Machine V2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Sun Microsystems > Servers
Exadata Database Machine V2 - Version All Versions to All Versions [Release All Releases]
All Platforms
Purpose
Provide additional information for message ID: SPX86-8002-RY
Details
Energy Storage Module is approaching end-of-life
Type
- Fault
- fault.chassis.device.esm.eol.warning
Severity
- Major
Description
- Energy Storage Module is approaching end-of-life.
Automated Response
- The service-required LED on the chassis will be illuminated.
Impact
- None.
Suggested Action for System Administrator
- The administrator should review the ILOM event log for additional information pertaining to this diagnosis. Please refer to the Details section of the Knowledge Article for additional information.
Details
Message ID: SPX86-8002-RY indicates that the ILOM fault manager has received an
error report that the Energy Storage Module (ESM) is approaching its expected lifespan.
Backup power may not be available in the event of a power loss.
FMOD's will operate in write-thru mode to prevent data loss or corruption.
- Sun Fire X4170 M2
Sun Fire X4270 M2
The service -required LED for the ESM Riser is located on the motherboard and will be illuminated.
The chassis-wide service required LED on the server will be illuminated.
Replace the ESM Riser. - Sun Fire X4470
The service-required LED for the Flash Riser module will be illuminated.
The chassis-wide service required LED on the server will be illuminated.
- If the Flash Riser service-required LED is illuminated and the FMOD service-required LED is NOT illuminated when the remind button on the flash riser is depressed, then replace the Flash Riser.
Replace the Flash Riser.
Sun Blade x6270 M2
Sun Blade X6275 M2
The service -required LED for the ESM Riser is located on the FEM and will be illuminated.
The chassis-wide service required LED on the server will be illuminated.
Replace the FEM.
Flash Accelerator F20 PCI card
The chassis-wide service required LED on the server will be illuminated.
Replace the ESM Module on the Flash Accelerator F20 PCI card.
- Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)