PCIEX-8000-SQ - Generic uncorrectable internal fault in PCIe Root Complex
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- SPARC T8-2
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
In this Document
Applies to:
Sun Microsystems > Servers
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
Information in this document applies to any platform.
Purpose
Provide additional information for message ID: PCIEX-8000-SQ
Details
Generic uncorrectable internal fault in PCIe Root Complex
Type
- Fault
- fault.io.pciex.rc.generic-ue
Severity
- Critical
Description
- An uncorrectable error was detected in the PCIe Root Complex.
Automated Response
- One or more device instances may be disabled
Impact
- Loss of services provided by the device instances associated with this fault
Suggested Action for System Administrator
- Schedule a repair procedure to replace the affected device if necessary, or contact Sun for support.
Details
- The Message ID: PCIEX-8000-SQ indicates a problem in the PCIe subsystem. The faulty components, as shown with fmdump, should be repaired in order to restore the system.
|