![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1168560.1 : ILOM-8000-30 - Top Level Identification indeterminate
In this Document
Applies to:SPARC M7-8SPARC M7-16 SPARC T7-1 SPARC T7-4 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional information for ILOM-8000-30 - Top Level Identification indeterminate DetailsType: Fault Major DescriptionThe message ID: ILOM-8000-30 indicates that the fault management function running on the service processor has determined the Top Level Identification of the system cannot be determined. Automated ResponseThe system will return UNKNOWN to Product identification requests. ImpactThe Product part number and serial number, as well as other important platform identification information, will be unknown. Suggested Action for System AdministratorThis event serves as a 'reminder' to update this information when the Primary FRU is replaced. The service person should be already on site and update the information as part of the FRU replacement. -> show /SYS
/SYS Targets: MB MB_ENV USBBD DVD PS0 SASBP PDB CONNBD FANBD HDD0 HDD4 INTSW PWRBS VPS T_AMB OK LOCATE SERVICE PS_FAULT TEMP_FAULT FAN_FAULT Properties: type = Host System ipmi_name = /SYS keyswitch_state = Normal product_name = SPARC T3-1 product_part_number = 602-4916-03 product_serial_number = BDL1024FDA product_manufacturer = Oracle Corporation fault_state = OK clear_fault_action = (none) power_state = On Commands: cd reset set show start stop ->
Attachments This solution has no attachment |
||||||||||||||||||||||||
|