Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1161926.1
Update Date:2015-12-22
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1161926.1 :   SPT-8001-3Y - Energy Storage Module has exceeded end-of-life  


Related Items
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC T7-2
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
 Description
 Automated Response
 Impact
 Suggested Action for System Administrator
References


Applies to:

Sun Microsystems > Servers
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
Information in this document applies to any platform.

Purpose

Additional information for SPT-8001-3Y - Energy Storage Module has exceeded end-of-life.

Details

Type: Fault

           fault.chassis.device.esm.eol.exceeded

Severity:  Major

Description

The message ID: SPT-8001-3Y indicates that the fault management function running on the service processor has determined the Energy Storage Module has exceeded end-of-life .

The ESM experiencing the fault can be identified following the procedures described in the document referenced under "Suggested Action for System Administrator".

Automated Response

The System Service Required LED will be illuminated.

Impact

Emergency backup power for FMODs (Flash MODules) is not available.

Suggested Action for System Administrator

The administrator should arrange to have the faulty ESM replaced.

Refer to the following document for the latest procedures and service policies to be applied in resolving this problem.

PSH Procedural Article for ILOM-Based Diagnosis (Doc ID 1155200.1)



Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.