Solution Type Predictive Self-Healing Sure Solution 1161885.1 : SPT-8000-RA - Current fail
In this Document
Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional Information for SPT-8000-RA - Current fail. DetailsType: Fault fault.chassis.current.fail DescriptionThe message ID: SPT-8000-RA indicates that the fault management function running on the service processor has determined that the system is drawing too much current. Automated ResponseThe system will be powered off. The chassis-wide service required LED will be illuminated. ImpactThe system may have permanent damage or this may have been a transient event. Further information cannot be determined until the system is powered on again. Suggested Action for System AdministratorThe administrator should arrange to have the FRU replaced. Attachments This solution has no attachment |
||||||||||||||||||||||||
|