![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1161873.1 : SPT-8000-PX - Component configuration fault
In this Document
Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional information for SPT-8000-PX - Component configuration fault. DetailsType: Fault fault.component.misconfigured DescriptionThe message ID: SPT-8000-PX indicates that the fault management function running on the service processor has determined that a FRU has been inserted into a location where it is not supported. Automated ResponseThe service required LED on the chassis may be illuminated. ImpactThe FRU may not be usable in its current location. Suggested Action for System AdministratorThis event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should review the ILOM event log for additional information pertaining to this diagnosis, determine which FRU is affected and take action to have the FRU removed. Attachments This solution has no attachment |
||||||||||||||||||||||||
|