![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1161868.1 : SPT-8000-US - Energy Storage Module (ESM) unable to charge
In this Document
Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional information for SPT-8000-US - Energy Storage Module (ESM) unable to charge. DetailsType: Fault DescriptionThe message ID: SPT-8000-US indicates that the fault management function running on the service processor has determined that a Energy Storage Module (ESM) was unable to achieve full charge within specified time. Automated ResponseFMODs will operate in write-thru mode to prevent data loss or corruption. ImpactEmergency backup power for FMODs is not available and system performance may be affected. Suggested Action for System AdministratorThe administrator should arrange to have the faulty ESM replaced. Attachments This solution has no attachment |
||||||||||||||||||||||||
|