Solution Type Predictive Self-Healing Sure Solution 1161867.1 : SPT-8000-T5 - PSU configured with AC low-line
In this Document
Applies to:SPARC M7-8Sun Microsystems > Servers SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. Purpose
DetailsType: Fault fault.chassis.power.inadequate DescriptionThe message ID: SPT-8000-T5 indicates that the fault management function running on the service processor has determined that a Server power-on was attempted on a system where one or more PSUs have low-line AC input and will not be able to supply enough power. Automated ResponsePower-on attempt will be denied. ImpactServer will not be allowed to power-on. Suggested Action for System AdministratorThis event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should review the ILOM event log for additional information to determine the affected power supplies. Attachments This solution has no attachment |
||||||||||||||||||||||||
|