Solution Type Predictive Self-Healing Sure Solution 1161863.1 : SPT-8000-NE - Missing or Invalid SCC
In this Document
Applies to:Sun Microsystems > ServersSPARC T7-1 SPARC T7-2 SPARC T7-4 SPARC T8-1 Information in this document applies to any platform. PurposeAdditional Information for SPT-8000-NE - Missing or Invalid SCC. DetailsType: Fault fault.scc.invalid DescriptionThe message ID: SPT-8000-NE indicates that the fault management function running on the service processor has determined that the SCC is either missing or invalid. Automated ResponseThe service required LED on the chassis may be illuminated. The SP network port will be disabled. ImpactThe Host will not be able to be powered on. Because the SCC provides the SP's MAC address, the SP network management port will be unusable. Suggested Action for System AdministratorThis event is generated as a result of inserting a FRU into the system and not installing the SCC on the replacement FRU. In the case of FRU replacement the service engineer should be on site to resolve the condition. PSH Procedural Article for ILOM-Based Alerts (Doc ID 1155200.1) Attachments This solution has no attachment |
||||||||||||||||||||||||
|