Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1161843.1
Update Date:2018-01-09
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1161843.1 :   SPT-8000-MJ - Power Supply general failure  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC M7-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC T7-4
  •  
  • SPARC M8-8
  •  
  • SPARC T8-2
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Scope
Details
 Description
 Automated Response
 Impact
 Suggested Action for System Administrator
References


Applies to:

Sun Microsystems > Servers
SPARC M7-8
Oracle SuperCluster M7 Hardware
SPARC M7-16
SPARC T7-1
Information in this document applies to any platform.

Purpose

This document provides additional Information for SPT-8000-MJ - Power Supply general failure.

Scope

 

Details

Type: Fault

           fault.chassis.power.fail

Severity: Critical

Description

The message ID: SPT-8000-MJ indicates that the fault management function running on the service processor has determined that a Power Supply  is not providing power to the server. The event can occur for a variety of reasons including AC power, AC Power cord unplugged etc....

The service required LED may be illuminated.

The specific power supply experiencing the fault can be identified following the procedures described Section A - Identify Component / FRU in the document referenced under "Suggested Action for System Administrator".

Automated Response

The service required LED on the chassis and on the affected Power Supply may be illuminated.

Impact

Server will be powered down when there are insufficient operational power supplies.

Suggested Action for System Administrator

This event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should verify air inlets are not obstructed, AC Power, AC Power cord are not unplugged, or other condition is not causing this event.

Should the administrator be unable to resolve the issue, use the following link for additional information for steps necessary to contact Oracle Service.

PSH Procedural Article for ILOM-Based Alerts (Doc ID 1155200.1)