![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1161834.1 : SPT-8000-LC - Power Supply voltage failure
In this Document
Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional information for SPT-8000-LC - Power Supply voltage failure. DetailsType: Fault fault.chassis.power.volt-fail DescriptionThe message ID: SPT-8000-LC indicates that the fault management function running on the service processor has determined that a Power Supply voltage level is outside of acceptable limits. Blade Products Note:
Blade products report this event, which is diagnosed by the service processor in the enclosure (CMM). It is intended as an informational event (an Alert) for blades and should not by itself be considered an event requiring service.
Automated ResponseThe service required LED on the chassis and on the affected Power Supply may be illuminated. ImpactServer will be powered down when there are insufficient operational power supplies Suggested Action for System Administrator
Blade Products Note:
This event is not a serviceable event for blades and should self-clear when the fan speed comes back within the specified range. However, should the condition be persistent, use the information from the above link in Section B Submitting a Service Request, sub-section Submitting a Service Request via the Support Center to request service. Attachments This solution has no attachment |
||||||||||||||||||||||||
|