Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional information for SPT-8000-7J - Power Supply Absent DetailsType: upset fault.chassis.power.missing DescriptionThe message ID: SPT-8000-7J indicates that the fault management function running on the service processor has determined that a power supply unit is absent. Blade Products Note:
Blade products report this event, which is diagnosed by the service processor in the enclosure (CMM). It is intended as an informational event (an Alert) for blades and should not by itself be considered an event requiring service.
Automated ResponseThe service-required LED on the chassis will be illuminated. This fault will self clear when the missing power supply is installed. ImpactServer will be powered down when if there are insufficient operational power supplies. Suggested Action for System AdministratorThis event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should review the ILOM event log for additional information pertaining to this diagnosis, determine which power supply is missing and take action to have the missing power supply re-installed. Blade Products Note:
This event is not a serviceable event for blades and should self-clear when the fan speed comes back within the specified range. However, should the condition be persistent, use the information from the above link in Section B Submitting a Service Request, sub-section Submitting a Service Request via the Support Center to request service. Attachments This solution has no attachment |
||||||||||||||||||||||||
|