Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1159425.1
Update Date:2015-12-21
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1159425.1 :   SPT-8000-7J - Power Supply Absent  


Related Items
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC T7-2
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  




In this Document
Purpose
Details
 Description
 Automated Response
 Impact
 Suggested Action for System Administrator
References


Applies to:

Sun Microsystems > Servers
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
Information in this document applies to any platform.

Purpose

Additional information for SPT-8000-7J - Power Supply Absent

Details

Type: upset

           fault.chassis.power.missing

Severity: Minor

Description

The message ID: SPT-8000-7J indicates that the fault management function running on the service processor has determined that a power supply unit is absent.

The power supply can be identified following the procedures described in the document referenced under "Suggested Action for System Administrator".

Blade Products Note:
Blade products report this event, which is diagnosed by the service processor in the enclosure (CMM). It is intended as an informational event (an Alert) for blades and should not by itself be considered an event requiring service.

 

Automated Response

The service-required LED on the chassis will be illuminated.  This fault will self clear when the missing power supply is installed.

Impact

Server will be powered down when if there are insufficient operational power supplies.

Suggested Action for System Administrator

This event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should review the ILOM event log for additional information pertaining to this diagnosis, determine which power supply is missing and take action to have the missing power supply re-installed.

Should the administrator be unable to resolve the issue, use the following link for additional information for steps necessary to contact Oracle Service.

PSH Procedural Article for ILOM-Based Alerts (Doc ID 1162995.1)

Blade Products Note:
This event is not a serviceable event for blades and should self-clear when the fan speed comes back within the specified range. However, should the condition be persistent, use the information from the above link in Section B Submitting a Service Request, sub-section Submitting a Service Request via the Support Center to request service.