![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1159413.1 : SPT-8000-6E - System has reached an over temperature condition
In this Document
Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional information for SPT-8000-6E - System has reached an over temperature condition. DetailsType: Fault fault.chassis.env.temp.over-fail DescriptionThe message ID: SPT-8000-6E indicates that the fault management function running on the service processor has determined that the ambient temperature is at or above the normal temperature threshold. Automated ResponseIlluminate service-required LED on the chassis. System will be powered down when the High Temperature threshold is reached. This fault will self clear once the temperature is within specifications. ImpactSystem may be powered down. Suggested Action for System AdministratorThis event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should determine the cause of the high ambient temperature condition and take actions to repair it. Attachments This solution has no attachment |
||||||||||||||||||||||||
|