Solution Type Predictive Self-Healing Sure Solution 1159385.1 : SPT-8000-42 - Chassis Device Missing
In this Document
Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeAdditional information for SPT-8000-42 - Chassis Device Missing DetailsType: Fault fault.chassis.device.missing DescriptionThe message ID: SPT-8000-42 indicates that the fault management function running on the service processor has determined that a device necessary to support a configuration is missing. Automated ResponseThe service required LED on the chassis will be illuminated. ImpactThe chassis may be powered down. Suggested Action for System AdministratorThis event is an alert intended to inform the user about a problem that is not typically associated with a fault in the product. Alerts do not normally require Oracle Services for resolution. The administrator should review the ILOM event log for additional information pertaining to this diagnosis, determine which device is missing and take action to have the missing device re-installed. Attachments This solution has no attachment |
||||||||||||||||||||||||
|