![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1159302.1 : SPT-8000-1Q - Chassis Device Fail
In this Document
Applies to:Sun Microsystems > ServersSPARC M7-8 SPARC M7-16 SPARC T7-1 SPARC T7-2 Information in this document applies to any platform. PurposeProvide additional information for SPT-8000-1Q 'Chassis Device Fail' DetailsType: Hardware Fault fault.chassis.device.fail Severity: Major DescriptionThe message ID: SPT-8000-1Q indicates that the fault management function running on the service processor has determined that a device located in the chassis that supports the server has failed. Automated Response.The service required LED on the chassis that supports the server may be illuminated. ImpactThe chassis may be powered down.. Suggested Action for System Administrator.The administrator should arrange to have the part replaced. Attachments This solution has no attachment |
||||||||||||||||||||||||
|