Asset ID: |
1-79-1022179.1 |
Update Date: | 2018-01-25 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1022179.1
:
SUN4V-8002-3R - Memory module correctable errors exceeding acceptable levels.
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SUN4V-8002-3R
Applies to:
Sun Microsystems > Servers
SPARC T4-2
All Platforms
Purpose
Provide additional information for message ID: SUN4V-8002-3R
Details
Predictive Self-Healing Article
Memory module correctable errors exceeding acceptable levels.
Type
- Fault
- fault.memory.dimm-page-retires-excessive
Severity
- Major
Description
- The number of correctable errors associated with this memory module has exceeded acceptable levels.
Automated Response
- Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.
Impact
- Total system memory capacity has been reduced.
Suggested Action for System Administrator
- Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
Product
Servers
Attachments
This solution has no attachment