Solution Type  Predictive Self-Healing Sure

Solution  1022179.1 :   SUN4V-8002-3R - Memory module correctable errors exceeding acceptable levels.  


Related Items
  • SPARC T4-2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
SUN4V-8002-3R


Applies to:

Sun Microsystems > Servers
SPARC T4-2
All Platforms

Purpose

Provide additional information for message ID: SUN4V-8002-3R

Details

Predictive Self-Healing Article
Memory module correctable errors exceeding acceptable levels.

Type

Fault
  fault.memory.dimm-page-retires-excessive

Severity

Major

Description

The number of correctable errors associated with this memory module has exceeded acceptable levels.

Automated Response

Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.

Impact

Total system memory capacity has been reduced.

Suggested Action for System Administrator

Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.


Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required.

PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)

 