Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1022012.1
Update Date:2017-12-22
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1022012.1 :   SUN4U-8007-KY - Memory module correctable errors exceeding acceptable levels.  


Related Items
  • Sun Fire V440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
SUN4U-8007-KY


Applies to:

Sun Microsystems > Servers
Sun Fire V440 Server
All Platforms

Purpose

Provide additional information for message ID: SUN4U-8007-KY

Details

Predictive Self-Healing Article
Memory module correctable errors exceeding acceptable levels.

Type

Fault
  fault.memory.dimm-page-retires-excessive

Severity

Major

Description

The number of correctable errors associated with this memory module has exceeded acceptable levels.

Automated Response

Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.

Impact

Total system memory capacity has been reduced.

Suggested Action for System Administrator

Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.

Details

The Message ID: SUN4U-8007-KY indicates a predicted problem with a memory module failing; it should be repaired in order to restore the system.



Product
Servers

Product_uuid
40db40e6-63d5-11d7-9870-9c8d0a1a6a33


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.