Asset ID: |
1-79-1022012.1 |
Update Date: | 2017-12-22 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1022012.1
:
SUN4U-8007-KY - Memory module correctable errors exceeding acceptable levels.
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
SUN4U-8007-KY
Applies to:
Sun Microsystems > Servers
Sun Fire V440 Server
All Platforms
Purpose
Provide additional information for message ID: SUN4U-8007-KY
Details
Predictive Self-Healing Article
Memory module correctable errors exceeding acceptable levels.
Type
- Fault
- fault.memory.dimm-page-retires-excessive
Severity
- Major
Description
- The number of correctable errors associated with this memory module has exceeded acceptable levels.
Automated Response
- Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.
Impact
- Total system memory capacity has been reduced.
Suggested Action for System Administrator
- Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.
Details
- The Message ID: SUN4U-8007-KY indicates a predicted problem with a memory module failing; it should be repaired in order to restore the system.
Product
Servers
Product_uuid
40db40e6-63d5-11d7-9870-9c8d0a1a6a33
Attachments
This solution has no attachment