Solution Type  Predictive Self-Healing Sure

Solution  1021622.1 :   ZFS-8000-HC - ZFS pool I/O failures  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC T7-4
  •  
  • SPARC M7-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • Solaris Operating System
  •  
  • SPARC T8-2
  •  
  • OpenSolaris Operating System
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
ZFS-8000-HC


Applies to:

OpenSolaris Operating System
Solaris Operating System
SPARC T8-1
SPARC T8-2
SPARC T8-4
All Platforms

Purpose

This document provides additional information for message ID: ZFS-8000-HC

Scope

 

Details

Predictive Self-Healing Article
ZFS-8000-HC - ZFS pool I/O failures

ZFS pool I/O failures

 

Type

Error
  fault.fs.zfs.io_failure_wait

Severity

Major

Description

The ZFS pool has experienced currently unrecoverable I/O failures.

Automated Response

No automated response will be taken.

Impact

Read and write I/Os cannot be serviced.

Suggested Action for System Administrator

The pool has experienced I/O failures. Since the ZFS pool property 'failmode' is set to 'wait', all I/Os (reads and writes) are blocked. See the zpool(1M) manpage for more information on the 'failmode' property. Manual intervention is required for I/Os to be serviced. You can see which devices are affected by running 'zpool status -x':

# zpool status -x
 

 pool: test

state: FAULTED

status: There are I/O failures.

action: Make sure the affected devices are connected, then run 'zpool clear'.

  see: http://www.sun.com/msg/ZFS-8000-HC

scrub: none requested

config:



       NAME        STATE     READ WRITE CKSUM

       test        FAULTED      0    13     0  insufficient replicas

         c0t0d0    FAULTED      0     7     0  experienced I/O failures

         c0t1d0    ONLINE       0     0     0



errors: 1 data errors, use '-v' for a list

After you have made sure the affected devices are connected, run 'zpool clear' to allow I/O to the pool again:

# zpool clear test

If I/O failures continue to happen, then applications and commands for the pool may hang. At this point, a reboot may be necessary to allow I/O to the pool again.

Details

The Message ID: ZFS-8000-HC indicates that the pool has experienced I/O failures. Take the documented action to resolve the problem.