1021334.1
:
PCIEX-8000-MH - PCIEX subsystem problem
Related Items |
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M8-8
- SPARC T7-2
- Oracle SuperCluster M8 Hardware
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
PCIEX-8000-MH
Applies to:
Sun Microsystems > Boards
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
All Platforms
Purpose
Provide additional information for message ID: PCIEX-8000-MH
Details
Predictive Self-Healing Article
PCIEX subsystem problem
Type
- Fault
- fault.io.pciex.device-interr-unaf
Severity
- Major
Description
- Too many recovered errors have been detected, which indicates a problem with the specified PCIEX device. This may degrade into an unrecoverable fault.
Automated Response
- One or more device instances may be disabled
Impact
- Loss of services provided by the device instances associated with this fault
Suggested Action for System Administrator
- Schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device or contact Sun for support.