Asset ID: |
1-79-1021332.1 |
Update Date: | 2017-03-29 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021332.1
:
PCIEX-8000-LA - PCIEX subsystem problem
Related Items |
- SPARC M7-8
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC T7-2
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
PCIEX-8000-LA
Applies to:
Sun Microsystems > Boards
SPARC M7-8
SPARC M7-16
SPARC T7-1
SPARC T7-2
All Platforms
Purpose
Provide additional information for message ID: PCIEX-8000-LA
Details
Predictive Self-Healing Article
PCIEX subsystem problem
Type
- Fault
- fault.io.pci.bus-linkerr-unaf
fault.io.pciex.device-interr-unaf
Severity
- Major
Description
- Too many recovered bus errors have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.
Automated Response
- One or more device instances may be disabled
Impact
- Loss of services provided by the device instances associated with this fault
Suggested Action for System Administrator
- If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.
Details
- Too many recovered bus errors have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.
Product
Boards
Product_uuid
e368db18-0fd5-11d8-84cb-080020a9ed93
Attachments
This solution has no attachment