Asset ID: |
1-79-1021310.1 |
Update Date: | 2018-01-09 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021310.1
:
PCIEX-8000-8R - PCIEX subsystem problem
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC T7-4
- Oracle SuperCluster M7 Hardware
- SPARC M7-8
- SPARC M8-8
- SPARC T8-2
- Oracle SuperCluster M8 Hardware
- SPARC T7-2
- SPARC M7-16
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
PCIEX-8000-8R
Applies to:
SPARC T8-1
SPARC T8-2
SPARC T8-4
Oracle SuperCluster M8 Hardware
SPARC M8-8
All Platforms
Purpose
This document provides additional information for message ID: PCIEX-8000-8R
Scope
Details
Predictive Self-Healing Article
PCIEX subsystem problem
Type
- Fault
- fault.io.pciex.device-invreq
Severity
- Major
Description
- The transmitting device sent an invalid request.
Automated Response
- One or more device instances may be disabled
Impact
- Loss of services provided by the device instances associated with this fault
Suggested Action for System Administrator
- Ensure that the latest drivers and patches are installed. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Oracle for support.
Details
- The transmitting device sent an invalid request.
Product
Boards
Product_uuid
e368db18-0fd5-11d8-84cb-080020a9ed93
Attachments
This solution has no attachment