Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1021219.1
Update Date:2017-09-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1021219.1 :   PCI-8000-DH - PCI subsystem problem  


Related Items
  • Sun Fire V880z Visualization Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Fire V440 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire V890 Server
  •  
  • SPARC M7-8
  •  
  • SPARC T7-4
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire 280R Server
  •  
  • Sun Fire 4810 Server
  •  
  • Sun Fire V1280 Server
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V480 Server
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire V445 Server
  •  
  • Sun Netra 440 Server
  •  
  • Sun Fire V490 Server
  •  
  • Sun Netra 1290 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
PCI-8000-DH


Applies to:

Sun Fire 280R Server - Version All Versions and later
Sun Fire 3800 Server - Version All Versions and later
Sun Fire 4800 Server - Version All Versions and later
Sun Fire 4810 Server - Version All Versions and later
Sun Fire 6800 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: PCI-8000-DH

Details

Predictive Self-Healing Article
PCI subsystem problem

Type

Fault
  fault.io.pci.bus-linkerr-unaf
  fault.io.pci.device-interr-unaf

Severity

Major

Description

Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.

Automated Response

One or more device instances may be disabled

Impact

Possible loss of services provided by the device instances associated with this fault

Suggested Action for System Administrator

If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device. Use fmadm faulty to identify the device and bus or contact Sun for support.

Details

Too many recovered bus faults have been detected, which indicates a problem with the specified bus or with the specified transmitting device. This may degrade into an unrecoverable fault.