Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-79-1021216.1
Update Date:2017-09-19
Keywords:

Solution Type  Predictive Self-Healing Sure

Solution  1021216.1 :   PCI-8000-95 - PCI subsystem problem  


Related Items
  • Sun Fire V880z Visualization Server
  •  
  • Sun Fire 15K Server
  •  
  • Sun Netra 1280 Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire V890 Server
  •  
  • Sun Fire E25K Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire V440 Server
  •  
  • SPARC M7-8
  •  
  • Oracle SuperCluster M7 Hardware
  •  
  • SPARC M8-8
  •  
  • Sun Fire 280R Server
  •  
  • Sun Fire 4810 Server
  •  
  • SPARC M7-4
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire 4800 Server
  •  
  • SPARC T7-2
  •  
  • Oracle SuperCluster M8 Hardware
  •  
  • Sun Fire V480 Server
  •  
  • SPARC M7-16
  •  
  • SPARC T7-1
  •  
  • Sun Fire V490 Server
  •  
  • Sun Netra 1290 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire E6900 Server
  •  
  • Sun Fire V445 Server
  •  
  • Sun Netra 440 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
  •  

PreviouslyPublishedAs
PCI-8000-95


Applies to:

Sun Fire 3800 Server - Version All Versions and later
Sun Fire 280R Server - Version All Versions and later
Sun Fire V480 Server - Version All Versions and later
Sun Fire 4800 Server - Version All Versions and later
Sun Fire 4810 Server - Version All Versions and later
All Platforms

Purpose

Provide additional information for message ID: PCI-8000-95

Details

Predictive Self-Healing Article
PCI subsystem problem

Type

Fault
  fault.io.pci.device-invreq
  fault.io.pci.device-noresp

Severity

Major

Description

Either the transmitting device sent an invalid request or the receiving device failed to respond.

Automated Response

One or more device instances may be disabled

Impact

Possible loss of services provided by the device instances associated with this fault

Suggested Action for System Administrator

Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmadm faulty to identify the devices or contact Sun for support.

Details

Either the transmitting device sent an invalid request or the receiving device failed to respond.

Note: If you have encountered this problem on a Sun Blade 1000 system, reported FRUs may be mislabeled. Please reference the following SRDB (Symptom Resolution Data Base) link for further information.