![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Predictive Self-Healing Sure Solution 1021145.1 : DISK-8000-4Q - The command was terminated with a non-recovered error condition that may have been caused by a flaw in the medium or an error in the recorded data
PreviouslyPublishedAs DISK-8000-4Q Applies to:Sun Microsystems > Storage - DiskSun Microsystems > Servers SPARC T7-1 SPARC T7-2 SPARC T7-4 All Platforms PurposeProvide additional information for message ID: DISK-8000-4Q DetailsType: Hardware Fault fault.io.scsi.cmd.disk.dev.rqs.merr Severity: Critical Automated Response The device may be offlined or degraded. A hot-spare disk may have been activated. Impact It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation. Suggested Action for System Administrator PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1) Attachments This solution has no attachment |
||||||||||||
|