Asset ID: |
1-79-1021142.1 |
Update Date: | 2017-09-22 |
Keywords: | |
Solution Type
Predictive Self-Healing Sure
Solution
1021142.1
:
DISK-8000-12 - A disk's temperature exceeded the limits established by its manufacturer
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC T7-4
- SPARC T8-2
- SPARC T7-2
- SPARC T7-1
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun PSH
|
PreviouslyPublishedAs
DISK-8000-12
Applies to:
Sun Microsystems > Storage - Disk
Sun Microsystems > Servers
SPARC T7-1
SPARC T7-2
SPARC T7-4
All Platforms
Purpose
Provide additional information for message ID: DISK-8000-12
Details
Type: Hardware Fault
fault.io.disk.over-temperature
Severity: Major
Description
The message ID: DISK-8000-12 indicates that a disk's temperature exceeded the limits established by its manufacturer.
Automated Response
None.
Impact
Performance degradation is likely and continued disk operation beyond the temperature threshold can result in disk damage and potential data loss.
Suggested Action for System Administrator
The administrator should identify the source of the over heating. If it's the disk itself arrange to have the faulty disk replaced.
Refer to the following document for the latest procedures for displaying event content in preparation for submitting a service request and applying any post-repair actions that may be required
PSH Procedural Article for Solaris FMA-Based Diagnosis (Doc ID 1173733.1)
Attachments
This solution has no attachment