![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Sun Alert Sure Solution 2353691.1 : False Positive Power Faults may be Seen on T5 Servers Without Firmware Version 9.6.20.b/9.6.20.c and HW Programmables 1.0.11 or Later
In this Document
Applies to:SPARC T5-2SPARC T5-4 SPARC T5-8 Oracle SuperCluster T5-8 Hardware Information in this document applies to any platform. SPARC __________________________________________ Date of Workaround Release: 26-Jan-2018 __________________________________________ DescriptionSPARC T5-2/T5-4/T5-8 systems without certain firmware versions and Hardware (HW) Programmables listed in the "Occurrence" section below may experience false positive power faults. OccurrenceThis issue can occur on the following platforms: SPARC Platform
To determine the firmware version installed on the system, the following command can be used: -> show /HOST sysfw_version SymptomsWhen this issue occurs, a false positive power glitch event resulting in a system outage may be seen. WorkaroundThere is no work around for this issue. Please see the Resolution section below. Resolution This issue is addressed in the following releases:
This is a two part fix that requires both system firmware and hardware programmables to be effective. The above firmware versions incorporate significant error handling improvements and other important bug fixes. A final Resolution is pending completion for Oracle SuperCluster T5-8 Patches<Patch:27043436> History26-Jan-2018: Document released, status Resolved Internal Section: Comments: This issue will be addressed for Oracle SuperCluster T5-8 with April 2018 QFSDP (when available) and HW Programmables 1.0.11 (as delivered in patch 25796761) or later Questions regarding this document should be addressed to Internal Contributor/Submitter: peter.mo@oracle.com References<BUG:26372629> - ADD ADDITIONAL CHECKING TO THE VALUES OF T5M GLITCH/POK REGISTERS<BUG:25543096> - T5 : MITIGATION OF CONTROLLER PINS COPPER SHORTS INSIDE INTERSIL ZL91XX MODULE Attachments This solution has no attachment |
||||||||||||||||||||||||
|