![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||
Solution Type Sun Alert Sure Solution 2339534.1 : System Firmware Version 9.8.0.c may Fail to Power On M7-8 Server CMIOU Boards (Firmware 9.8.0.c is WITHDRAWN)
In this Document
Applies to:Sun Software - GenericSun Hardware - Generic SPARC M7-8 Information in this document applies to any platform. SPARC ___________________________________________ Date of Resolved Release: 15-Dec-2017 ___________________________________________ DescriptionSPARC M7-8 servers running firmware version 9.8.0.c may fail to power on CMIOU boards. Firmware version 9.8.0.c has been WITHDRAWN and is no longer available for download. OccurrenceThis issue can occur on the following platform: SPARC Platform
To determine the firmware version installed on the system, use the following ILOM command: -> show /HOST sysfw_version /HOST SymptomsIf the described issue occurs, the server will fail to power on a CMIOU board. An ERROR message similar to the following will be displayed in the HOST console: 2017-10-31 02:07:29 0:00:0> ERROR: /SYS/CMIOU3/CM/CMP: Failed to sign on and the ILOM command 'show faulty' will contain output similar to the following: -> show faulty WorkaroundThere is no workaround for this issue. Please see the Resolution below. Resolution This issue is addressed on the following platform: SPARC Platform
Note: Loading new system firmware requires the host to be stopped and restarted to deploy HOST firmware fixes. See <Document:1542610.1> for all information regarding the system firmware upgrade procedure. Patches
History15-Dec-2017: Document released, status is Resolved This is software problem. When CPUs are executing from the fast host flash, a chip reset occurs. Questions regarding any portion of this document must Internal Contributor/Submitter: david.lafko@oracle.com References<BUG:26969854> - M7:CMIOUS FAILING TO POWER ON WITH 9.8.0.CAttachments This solution has no attachment |
||||||||||||||||||||||||
|