![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||||||||
Solution Type Sun Alert Sure Solution 2293794.1 : Recommended Update V2.22 for Acme Packet 4500/3820 Devices with QoS FPGA
In this Document
Applies to:Acme Packet 4500 - Version S-Cz7.1.2 to S-Cz7.4.0 [Release S-Cz7.0]Acme Packet 4500 - Version E-Cz7.3.0 to E-Cz7.4.0 [Release E-Cz7.0] Acme Packet 3820 - Version E-Cz7.3.0 to E-Cz7.3.0 [Release E-Cz7.0] Acme Packet 4500 Acme Packet 3820 DescriptionAn issue has been identified within Session Border Controllers (SBCs) running Linux-based software (SCZ7.x or ECZ7.x) on AP 4500/3820 devices with QoS NIUs (Network Interface Unit), wherein the SBC will hang periodically for no apparent reason, and no events written to logs. This Alert document describes the procedure to identify potentially impacted systems, and recommended proactive mitigations. OccurrenceImpacted DevicesThis behavior is specific to AP4500/3820 platform with NIUs using the QoS FPGA, running Linux based releases (7.x).
Identify the PlatformPotential hardware may be verified with the 'show prom-info phy' command: show prom-info phy
Contents of PHY Assy, 4 Port SFP with QOS and IPSec Part Number: 002-0613-58 Serial Number: 151049008345 FunctionalRev: 04.02 BoardRev: 04.00 PCB Family Type: Quad port GiGE SFP PHY ID: 4 Port GiGE w/QoS & Encryption
Cx6xx Releases Use the 'show qos revision' command to check the FPGA version. ACME SBC# show qos revision
QoS FPGA Hardware Revision is 1.202 Cz7xx Releases Use the 'show datapath ppx info' command to check the FPGA version. ACME SBC# show datapath ppx info
4500 ZappPPX Information ==== ====== =========== ======== QoS Stats =========== QoS FPGA Hardware Revision is 1.202
Identify the ReleaseIf needed, the 'show version image' command may be used to determine if the SBC is running a 7.x release of Linux (SCZ7xx or ECZ7xx). show version image
Linux (Acme Packet Net-Net 4500) version 3.8.13-el6uek.v3.8.13-118.6.1-cov Boot line: eth(0,0)sbc:/boot/nnSCZ730m2.64.bz e=1.1.1.3:ffffff00 g=1.1.1.1 u=vxftp pw=vxftp tn=sbc SymptomsImpacted SBC nodes may appear to hang periodically, with no apparent reason, and nothing relevant written to logs regarding possible cause. The following are some of the symptoms attributed to manifestations of this behavior:
This is specific to devices outlined above that have been upgraded from vxWorks release 6.x to Linux release 7.x Additional symptoms may be outlined within Document 2278470.1, when identified. PatchesTo resolve this behavior, SBC Administrators are advised to upgrade the FPGA to version 2.22 <Patch 24369382> or later. Note: This FPGA is supported on both 4500 and 3820 with applicable cards above.
These patches may be downloaded using the links above, or from the My Oracle Support (MOS) Portal directly, by connecting to https://support.oracle.com with an internet browser.
History03-AUG-2017 - Initial draft of document. References<NOTE:2278470.1> - AP3820 or AP4500 with QoS NIU Hangs When Running Linux 7.x ReleaseAttachments This solution has no attachment |
||||||||||||||||||||||||||||
|