Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-2234866.1
Update Date:2017-04-11
Keywords:

Solution Type  Sun Alert Sure

Solution  2234866.1 :   The CGPCACTION Parameter Values In GTA Entries May Get Reset To Default Value After Upgrade  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  


The CGPCACTION Parameter Values In GTA Entries May Get Reset To Default Value After Upgrade

In this Document
Description
Occurrence
Symptoms
Workaround
Patches
History
References


Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.3 to EAGLE 46.4 [Release EAGLE 46.0]
Information in this document applies to any platform.

Description

If upgrading the Eagle to target release 46.3 or 46.4, the CGPCACTION parameter values in GTA entries which are configured other than to default value "dflt" will get reset to default value "dflt" after the upgrade. Hence it may cause traffic impact on EAGLEs containing GTA entries with non-default "CGPCACTION" parameter values (if the particular GTA entry is handling specific traffic which requires a non-default "CGPCACTION" value to handle it correctly) during upgrade phase 3 and until the GTA entries are set back with appropriate "CGPCACTION" parameter value.

Occurrence

This problem may occur if all of the following conditions are true.

  1. EAGLE is being upgraded to target release 46.3 or 46.4.
  2. GTA entries are configured with the "CGPCACTION" parameter values other than to default value "dflt" i.e. "ignore" or "remove".

Below sample capture shows GTA entries with CGPCACTION as remove, ignore, dflt.

    START GTA       END GTA         XLAT   RI     PC
    33689013020     33689013020     dpc    gt     04004
         MRNSET=dflt  SSN=--- CCGT=no
         GTMODID=---------  TESTMODE=off
         FALLBACK=sysdflt CGCNVSN=---------
         OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
         ACTSN=--------- PPMEASREQD= no
         CGPCACTION=remove
      START GTA       END GTA         XLAT   RI     PC
    917838661843    917838661843    dpc    gt     04444
         MRNSET=dflt  SSN=--- CCGT=no
         GTMODID=---------  TESTMODE=off
         FALLBACK=sysdflt CGCNVSN=---------
         OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
         ACTSN=--------- PPMEASREQD= no
         CGPCACTION=ignore
      START GTA       END GTA         XLAT   RI     PC
    919897889776    919897889776    dpc    gt   s-04000
         MRNSET=dflt  SSN=--- CCGT=no
         GTMODID=---------  TESTMODE=off
         FALLBACK=sysdflt CGCNVSN=---------
         OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
         ACTSN=--------- PPMEASREQD= no
         CGPCACTION=dflt

 

Symptoms

Before upgrade GTA entries present with CGPCACTION parameter values remove or ignore.

    START GTA       END GTA         XLAT   RI     PC
    33689013020     33689013020     dpc    gt     04004
         MRNSET=dflt  SSN=--- CCGT=no
         GTMODID=---------  TESTMODE=off
         FALLBACK=sysdflt CGCNVSN=---------
         OPTSN=--------- CGSELID=----- CDSELID=-----    OPCSN=---------
         ACTSN=--------- PPMEASREQD= no
         CGPCACTION=remove
      START GTA       END GTA         XLAT   RI     PC
    917838661843    917838661843    dpc    gt     04444
         MRNSET=dflt  SSN=--- CCGT=no
         GTMODID=---------  TESTMODE=off
         FALLBACK=sysdflt CGCNVSN=---------
         OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
         ACTSN=--------- PPMEASREQD= no
         CGPCACTION=ignore

 Post upgrade GTA entries earlier present with CGPCACTION parameter values ignore or remove changed to default value dflt.

      START GTA       END GTA         XLAT   RI     PC
    33689013020     33689013020     dpc    gt     04004
         MRNSET=dflt  SSN=--- CCGT=no
         GTMODID=---------  TESTMODE=off
         FALLBACK=sysdflt CGCNVSN=---------
         OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
         ACTSN=--------- PPMEASREQD= no
         CGPCACTION=dflt
      START GTA       END GTA         XLAT   RI     PC
    917838661843    917838661843    dpc    gt     04444
         MRNSET=dflt  SSN=--- CCGT=no
         GTMODID=---------  TESTMODE=off
         FALLBACK=sysdflt CGCNVSN=---------
         OPTSN=--------- CGSELID=----- CDSELID=----- OPCSN=---------
         ACTSN=--------- PPMEASREQD= no
         CGPCACTION=dflt

 

Workaround

  1. Prior to upgrade execute these commands rtrv-gta:gttsn=<gttset_name>:CGPCACTION=ignore ; rtrv-gta:gttsn=<gttset_name>:CGPCACTION=remove and prepare the list of GTT entries for which CGPCACTION parameter will be getting reset to default value "dflt" after the upgrade. After successful completion of upgrade, execute chg-gta:gttsn=<gttset_name>:gta=<>:egta=<>:CGPCACTION=<pre-upgrade value> command to reconfigure such GTT entries with the pre-upgrade CGPCACTION values.
  2. If there are such entries present before the upgrade then such traffic may be stopped for the upgrade period.

 

Patches

1. It will be fixed in EAGEL 46.5. Planned GA 11 July 2017.
2. It will be fixed in EAGLE 46.3.1. Date TBD.

History

17-Feb-2017 - Initial draft

21-Feb-2017 - Updated based on review comments

22-Feb-2017 - Updated based on review comments

 

References

<BUG:25170994> - THE "CGPCACTION" PARAMETER VALUE DOES NOT CARRY THROUGH DURING UPGRADE

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback