Solution Type  Sun Alert Sure

Solution  2141036.1 :   Diameter Signaling Router (DSR) - Secondary Path Does not Pick Up Traffic when Primary Path Fails on IPFE IPv6 SCTP Multihoming  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Description
Occurrence
Symptoms
Workaround
Patches
History
References


Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 to DSR 7.2.0 [Release DSR 5.0 to DSR 7.0]
Information in this document applies to any platform.

Description

SCTP Multi Homing secondary path does not pick up traffic when primary path fails in case of IPV6 and IPFE.

This issue will not occur if fixed connections are used.

Occurrence

The issue can happen when all conditions below are met:

  • IPFE feature is used
  • IPv6 is used
  • SCTP Multihoming is enable

Then, if primary path is failing, the messages do not get routed over the secondary connection.

Symptoms

NA

Workaround

None.

Patches

No patch is planned, fix is planned for next DSR release