Solution Type Sun Alert Sure Solution 2119344.1 : Impact on EAGLE Measurements When PLATFORMENABLE and OAMHCMEAS Are Set To "On" in MEASOPTS Table
In this Document
Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 44.0.0 and laterTekelec DescriptionAfter Measurements Platform to E5-OAM Integrated Measurements migration, both PLATFORMENABLE and OAMHCMEAS should not be "on" in MEASOPTS table. For correct condition, verify that Measurements Platform to E5-OAM integrated measurements migration is successful by displaying MEASOPTS table entries ( RTRV-MEASOPTS ). This will indicate "OAMHCMEAS as ON" and "PLATFORMENABLE as OFF". OccurrenceThis may occur when migration from Measurements Platform to E5-OAM Integrated Measurements is executed when following are true: SymptomsPost-migration, both PLATFORMENABLE and OAMHCMEAS will be set to "on" in MEASOPTS table. WorkaroundThe system need to be rolled back to the source release, fix the issue by following the correct procedure by having MCPM type card in the system until transition to E5-OAM Integrated Measurements completes, then upgrade the system back. History22-MAR-2016 - KM Document Created. 23-MAR-2016 - Implements comments. Attachments This solution has no attachment |
||||||||||||||||||||
|