Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-2096263.1
Update Date:2016-01-27
Keywords:

Solution Type  Sun Alert Sure

Solution  2096263.1 :   EAGLE Releases 46.0.2.0.0 and 46.2.0.0.0 - GT routed SCCP Class1 traffic in the system generates gratuitous broadcast packets on IMT bus  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Description
Occurrence
Symptoms
Workaround
History
References


Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.0 to EAGLE 46.2 [Release EAGLE 46.0]
Tekelec

Description

GT routed SCCP Class1 traffic in the system (EAGLE running Release 46.0.2.0.0 or 46.2.0.0.0) generates gratuitous broadcast packets on IMT bus (BUG 21896172) which may consume some additional system resources. This may reduce the usable IMT bus throughput and/or consume additional CPU cycles on system cards. This alert is not applicable to EAGLE releases 46.0.0.0.0, 46.0.1.0.0 and 46.1.0.0.0.

Occurrence

This can occur when following conditions are true
1) EAGLE running Release 46.0.2.0.0 or 46.2.0.0.0
2) EAGLE is GT routing SCCP class1 traffic (rept-stat-sccp:mode=perf command can be executed to verify this).
3) Class1seq under SCCPOPTS is turned ON (rtrv-sccpopts command can be executed to verify this).

Symptoms

Any one of the following symptoms will be observed if the system is hitting BUG 21896172.

1) following severity 1 troubles from network cards

EAGLESTP yy-mm-dd hh:mm:ss EST EAGLE5 46.x.x-xx.xx.xx
Card 1205 Module mfc_snif.c Line 549 Class 01d0 Severity 1
0e 00 00 00 1d 00 00 00 df 15 59 00 03 c0 04 32 ..........Y....2
82 0e 09 01 01 43 01 43 17 5d 00 00 .....C.C.]..

and/or

EAGLESTP yy-mm-dd hh:mm:ss EST EAGLE5 46.x.x-xx.xx.xx
Card 1305 Module mfc_serv_cnt Line 463 Class 01d0 Severity 1
1e ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ................
01 00 00 00 1d 00 00 00 6d b5 b6 00 01 00 00 00 ........m.......

2) Flash-card/init-flash command completion failure (CARD FLASH OPERATION FAILURE) on system cards.

Workaround

Halt all scheduled EAGLE upgrade to releases 46.0.2.0.0 and 46.2.0.0.0. New maintenance releases with fix for BUG 21896172 will be provided for the affected releases.
If the EAGLE is currently running release 46.0.2.0.0 or 46.2.0.0.0, it must be upgraded to a release with fix for BUG 21896172, as soon as available. Please contact Oracle customer support team for more details.

History

13-JAN-2016 - KM Document Created.

References

<BUG:21896172> - 46.2 - MODULE MFC_SERV_CNT LINE 466 CLASS 01D0 SEVERITY 1 GENERATED ON E5 E1

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.