![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Sun Alert Sure Solution 2096263.1 : EAGLE Releases 46.0.2.0.0 and 46.2.0.0.0 - GT routed SCCP Class1 traffic in the system generates gratuitous broadcast packets on IMT bus
In this Document
Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 46.0 to EAGLE 46.2 [Release EAGLE 46.0]Tekelec DescriptionGT routed SCCP Class1 traffic in the system (EAGLE running Release 46.0.2.0.0 or 46.2.0.0.0) generates gratuitous broadcast packets on IMT bus (BUG 21896172) which may consume some additional system resources. This may reduce the usable IMT bus throughput and/or consume additional CPU cycles on system cards. This alert is not applicable to EAGLE releases 46.0.0.0.0, 46.0.1.0.0 and 46.1.0.0.0. OccurrenceThis can occur when following conditions are true SymptomsAny one of the following symptoms will be observed if the system is hitting BUG 21896172. 1) following severity 1 troubles from network cards EAGLESTP yy-mm-dd hh:mm:ss EST EAGLE5 46.x.x-xx.xx.xx and/or EAGLESTP yy-mm-dd hh:mm:ss EST EAGLE5 46.x.x-xx.xx.xx 2) Flash-card/init-flash command completion failure (CARD FLASH OPERATION FAILURE) on system cards. WorkaroundHalt all scheduled EAGLE upgrade to releases 46.0.2.0.0 and 46.2.0.0.0. New maintenance releases with fix for BUG 21896172 will be provided for the affected releases. History13-JAN-2016 - KM Document Created. References<BUG:21896172> - 46.2 - MODULE MFC_SERV_CNT LINE 466 CLASS 01D0 SEVERITY 1 GENERATED ON E5 E1Attachments This solution has no attachment |
||||||||||||||||||||||
|