Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1606588.1
Update Date:2013-12-17
Keywords:

Solution Type  Sun Alert Sure

Solution  1606588.1 :   Sun System Firmware 8.3.1 Contains ILOM 3.2.1.5.j Which has an Erroneous Version String of 3.1.2.5.j  


Related Items
  • SPARC T3-1B
  •  
  • SPARC T3-4
  •  
  • Netra T3-1
  •  
  • SPARC T3-2
  •  
  • Netra SPARC T3-1B
  •  
  • SPARC T3-1 (Serpa)
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun Alert
  •  
  • _Old GCS Categories>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • _Old GCS Categories>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  




In this Document
Description
Occurrence
Symptoms
Workaround
Patches
History
References


Applies to:

SPARC T3-1B
SPARC T3-2
SPARC T3-4
Netra T3-1
Netra SPARC T3-1B
Information in this document applies to any platform.
________________________________________



Date of Workaround Release: 09-Dec-2013

Date of Resolved Release: 17-Dec-2013
________________________________________

Description

Sun System Firmware 8.3.1 contains ILOM (Integrated Lights-Out Management) version 3.2.1.5.j. However, this ILOM release has an erroneous version string of 3.1.2.5.j. This erroneous version string can be ignored - an ILOM 3.1.x version was never released for SPARC platforms. Any ILOM from the system reading version 3.1.2.5.j, is in fact version 3.2.1.5.j.

Note: Patches (as listed below) for the System Firmware containing the erroneous version string are WITHDRAWN and are no longer available for download. 

Occurrence

This issue can occur on the following platforms:

SPARC Platform

  • SPARC T3-1 with Sun System Firmware version 8.3.1 (as delivered in patch 150407-04)
  • SPARC T3-1B with Sun System Firmware version 8.3.1 (as delivered in patch 150410-04)
  • SPARC T3-2 with Sun System Firmware version 8.3.1 (as delivered in patch 150408-04)
  • SPARC T3-4 with Sun System Firmware version 8.3.1 (as delivered in patch 150409-04)
  • Netra SPARC T3-1 with Sun System Firmware version 8.3.1 (as delivered in patch 150411-04)
  • Netra SPARC T3-1B with Sun System Firmware version 8.3.1 (as delivered in patch 150412-04)

Symptoms

When inspecting the ILOM version, the following will be seen:

      > version
      SP firmware 3.1.2.5.j
      SP firmware build number: 84611

the above output showing the erroneous version number of 3.1.2.5.j

This erroneous version string is also shown in the affected patch READMEs as shown below (or with similar time stamps):

      ILOM 3.1.2.5.j Oct 28 13:06:20 PDT 2013

Workaround

No workaround is required for this issue; simply interpret the ILOM version 3.1.2.5.j as the actual correct version 3.2.1.5.j.

This issue is addressed in the following releases:

SPARC Platform

  • SPARC T3-1 Sun System Firmware version 8.3.1.b, as delivered in patch 150407-05
  • SPARC T3-1B Sun System Firmware version 8.3.1.b, as delivered in patch 150410-05
  • SPARC T3-2 Sun System Firmware version 8.3.1.b, as delivered in patch 150408-05
  • SPARC T3-4 Sun System Firmware version 8.3.1.b, as delivered in patch 150409-05
  • Netra SPARC T3-1 Sun System Firmware version 8.3.1.b, as delivered in patch 150411-05
  • Netra SPARC T3-1B Sun System Firmware version 8.3.1.b, as delivered in patch 150412-05

Patches

<SUNPATCH:150407-05>
<SUNPATCH:150408-05>
<SUNPATCH:150409-05>
<SUNPATCH:150410-05>
<SUNPATCH:150411-05>
<SUNPATCH:150412-05>

History

09-Dec-2013: Document released; status Workaround
10-Dec-2013: Erroneous Patches are now withdrawn from MOS
17-Dec-2013: System Firmware 8.3.1.b is released, issue is resolved



Questions regarding this document should be addressed to
sunalertpublication_us_grp@oracle.com and copy the
responsible engineer/submitter listed below.

Internal Contributor/Submitter: chris.boland@oracle.com
Internal Eng Responsible Engineer:  chris.boland@oracle.com
Oracle Knowledge Analyst: david.mariotto@oracle.com
Internal Eng Business Unit Group: Systems RPE
Internal Associated SRs:
Internal Resolution Patches: TBD

References









Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback