![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||||
Solution Type Sun Alert Sure Solution 1405209.1 : ZFS 7310C/7410C Systems With Certain Ethernet Cards may be Unable to Rejoin Cluster
In this Document
Applies to:Sun Microsystems > Storage SoftwareSun Microsystems > Storage - Disk > Unified Storage Sun Software - Generic - Version Not Applicable and later Sun Storage 7310 Unified Storage System - Version Not Applicable and later Sun Storage 7410 Unified Storage System - Version Not Applicable and later Information in this document applies to any platform. ___________________________________ Date of Workaround Release: 03-Feb-2012 Date of Resolved Release: 24-Feb-2012 ***Checked for relevance 06-Jan-2014*** ___________________________________ DescriptionAfter performing an update to the ZFS 7000 Storage Appliance Software 2011.1.1.0 release, Sun ZFS 7310C/7410C appliances with Cluster Controller 100 cards (PN: 371-3024-01) and 4x1Gb Copper Ethernet cards (PN: 375-3481-01) may be unable to rejoin the cluster. OccurrenceThis issue can occur on the following platforms:
with ZFS Storage Appliance Software 2011.1.1.0 release and one of the ethernet cards listed below (see Note 1.) 371-3024-01 Cluster Controller 100 (Fishworks CLUSTRON 100) card 2. To determine the current Storage Appliance Software revision, run the following command: 7000:> maintenance system updates list UPDATE DATE STATUS ak-nas@2011.04.24.1.0,1-1.8 2011-12-21 22:32:50 current 3. The following command can be run prior to a software update from the Software CLI to determine if the system has the cards that can cause the issue. For example: 7410:> maintenance hardware select chassis-000 select slot show Slots: LABEL STATE MANUFACTURER MODEL slot-000 PCIe 3 ok Sun Microsystems, Inc. 4x1Gb Copper Ethernet slot-001 PCIe 1 ok Sun Microsystems, Inc. Dual 4x6Gb External SAS-2 HBA slot-002 PCIe 5 ok Sun Microsystems, Inc. Fishworks CLUSTRON 100 ... SymptomsOn a system that has this issue, the following warning messages will be displayed on the system console during boot: SunOS Release 5.11 Version ak/generic@2011.04.24.1.0,1-1.8 64-bit Copyright (c) 1983, 2010, Oracle and/or its affiliates. All rights reserved. Configuring devices.WARNING: Cannot register interrupt for 'pciex8086,10bc' device at IPL 7 because it conflicts with another device using the same vector 40 with an IPL of 12. Reconfigure the conflicting devices to use different vectors.WARNING: Sharing vectors: pci8086,1026 instance 4 and pciex8086,10bc instance 3 In addition, the system will not be able to rejoin the cluster, and the following message will be displayed continuously on the system console: This appliance is part of an appliance cluster. Please wait while cluster synchronization takes place.Joining cluster ... / WorkaroundIf the above symptoms occur after an update to the Storage Appliance Software 2011.1.1.0 release, a rollback to the previous software release should be performed. For example: 7410:> maintenance system updates select ak-nas@2010.08.17.4.2,1-1.37 rollbackYou have requested a rollback of the system software to an earlier version. To complete the rollback of the system to this earlier version, the system will be rebooted, and a snapshot of the system configuration at the time that image was last running will be restored. This process will erase any system settings applied since that time. Do you wish to reboot the system, proceed with rollback, and erase all configuration changes made since you updated from this software version?Are you sure? (Y/N) Y
Sun ZFS Storage Appliance Software information can be found in <Document:2021771.1>. History03-Feb-2012: Date of Workaround release ReferencesAttachments This solution has no attachment |
||||||||||||||||||||||
|