Solution Type Sun Alert Sure Solution 1128605.1 : Firmware for RAID Controllers Causes Unscheduled Simultaneous Reboot of Controllers After 828.5 Days of Continuous Operation
In this Document
Applies to:Sun Storage 2510 Array - Version Not Applicable to Not Applicable [Release N/A]Sun Storage 2540 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage Flexline 380 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 6180 Array - Version Not Applicable to Not Applicable [Release N/A] Sun Storage 6140 Array - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. _______________________________________ Date of Resolved Release: 18-Jun-2010 _______________________________________ DescriptionA known issue with vxWorks RAID controller firmware for Sun StorageTek arrays (as listed in Section 2) may cause drives associated with host/IO volumes to experience write failures when the controllers reboot. This issue can occur after approximately 828.5 days of uptime, when vxWorks (by default) is scheduled for a simultaneous auto-reboot of the controllers. OccurrenceThis issue can occur on the following platforms:
running vxWorks Controller Firmware versions 6.70.xx or earlier. This issue is not restricted to the above arrays, as this firmware may also be used with other arrays, servers, or switches.
To determine the version of firmware on the controller, please view the Common Array Manager (CAM) Storage System Summary page of the CAM host managing the array. SymptomsRAID arrays using software mirroring to mirror data between the two arrays perform an unscheduled simultaneous reboot at nearly the same time (approximately 828.5 days uptime), causing a write failure. WorkaroundTo avoid the (unscheduled) controller auto-reboot, alternately reboot the controllers anytime between 1 day uptime and 800 days uptime to restart the counter prior to vxAbsTicks rollover. With a proper failover environment, there should be no interruption of service. Even with a workaround of rebooting each controller prior to the vxAbsTicks rollover, the issue will still be experienced after the reboot of the controllers every ~828 days by arrays with 6.x firmware revision.
This issue is resolved in the firmware 07.35.10.10 or later for the 25xx series and 07.15.11.12 or later for the 6xxx series. The fix changes the reboot schedule to different times for each controller without the need for a manual reboot. (Reboot date/time can still be scheduled manually). NOTE: This Alert describes a specific problem in 6.xx firmware where both controllers can reboot SIMULTANEOUSLY. The fix changes the reboot schedule to different times for each controller without the need for a manual reboot. (Reboot date/time can still be scheduled manually). You cannot upgrade directly from 6.x firmware to 7.x. You must first upgrade to the firmware bundled in the upgrade utility then use CAM to upgrade to the required firmware level.
See also: "Procedure to Upgrade the Sun StorageTek[TM] 6540 Array, 6140 Array or FLX380 Storage Array from Firmware 06.xx to 07.xx." <Document: 1131593.1> and "Procedure to Upgrade the Sun StorageTek[TM] 2500 Series Array Controller Firmware from 06.xx to 07.xx." <Document:1319254.1> and "How to Determine Uptime of Sun Storage[TM] 2500, 2500-M2 and 6000 Disk Arrays" <Document:1455525.1>.
History18-Jun-2010: Document created, issue is Resolved Questions regarding this document should be addressed to: References<NOTE:1011474.1> - Sun Storage 6140 Array Firmware Matrix<NOTE:1011551.1> - Sun StorageTek[TM] Flexline 380 (FLX380) with Common Array Manager (CAM) Firmware Matrix <NOTE:1017877.1> - Sun StorageTek[TM] 2540 (FC) Firmware Matrix <NOTE:1021780.1> - Sun StorageTek[TM] 2510 (iSCSI) Firmware Matrix <NOTE:1022296.1> - Sun Storage[TM] 6180 Firmware Matrix <NOTE:1005365.1> - Sun StorageTek[TM] 2530 (SAS) Firmware Matrix <NOTE:1009934.1> - Sun StorageTek[TM] 6540 Firmware Matrix <NOTE:1022298.1> - Sun Storage[TM] 6580/6780 Firmware Matrix <NOTE:1131593.1> - Procedure to Upgrade the Sun StorageTek[TM] 6540 Array, 6140 Array or FLX380 Storage Array from Firmware 06.xx to 07.xx. <NOTE:1319254.1> - Procedure to Upgrade the Sun StorageTek[TM] 2500 Series Array Controller Firmware from 06.xx to 07.xx. <NOTE:1569641.1> - Controllers in a Sun Storage 6000/2500/2500-M2/Flexline Array Have an 820 Day Uptime Limit Attachments This solution has no attachment |
||||||||||||||||||||||
|