![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Sun Alert Sure Solution 1022254.1 : Brocade Upgrade may Result in Switch Reboot Failure
PreviouslyPublishedAs 278490 Bug Id <BUG: 15626738> Date of Resolved Release 12-Mar-2010 Brocade Upgrade may Result in Switch Reboot Failure 1. ImpactWhen a DCX, DCX-4S or Brocade 5300 is upgraded the Control
Processor (CP) blade may fail 2. Contributing FactorsThis issue can occur on the following platforms:
Notes: This issue only affects the DCX, DCX4-S and 5300 and only occurs when upgrading from: - FOS v6.1x - FOS 6.2.0x - FOS 6.3.0x To
determine the firmware level of the switch type, use the "version"
command at the command line. 3. SymptomsThe upgrade operation fails and the Compact Flash (CF) may report
an access error. For
the Brocade 5300, the switch fails to reboot. 4. WorkaroundThere is no recovery when this occurs and you will need to contact your normal support channels.
This issue is addressed with the following releases:
References<SUNPATCH: 142801-03><SUNPATCH: 140810-08> Internal Comments (for SAs) Product Info: Internal Contributor/submitter Adli.Waziri@Sun.COM Internal Eng Responsible Engineer adli.waziri@sun.com Internal Services Knowledge Engineer karen.edwards@sun.com Internal Eng Business Unit Group Network Storage Internal Resolution Patches 142801-03, 140810-08 Internal Sun Alert & FAB Admin Info 10-Mar-2010: karen, submitted today and sent to 24hr review today. Attachments This solution has no attachment |
||||||||||||
|