Patches Delivering OBP Firmware Versions 4.30.3, 4.30.3.b or 4.30.4 (WITHDRAWN) may Cause a System to Fail to Boot
Related Items |
- Sun Netra 240 (DC) Server
- Sun Fire V240 Server
- Sun Netra 210 Server
- Sun Fire V125 Server
- Sun Fire V250 Server
- Sun Blade 2500 Workstation
- Sun Fire V210 Server
- Sun Blade 1500 Workstation
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: Sun Alert
- _Old GCS Categories>Sun Microsystems>Sun Alert>Release Phase>Resolved
|
PreviouslyPublishedAs
276870
Bug Id
<BUG:15595565>
ProductSun Fire V125 Server
Sun Fire V210 Server
Sun Fire V240 Server
Sun Fire V250 Server
Netra 210 Server
Netra 240 Server
Sun Blade 1500 Workstation
Sun Blade 2500 Workstation
Date of Workaround Release04-Feb-2010
Date of Resolved Release10-Feb-2010
***Checked for relevance 12-Jun-2013***
1. Impact
Systems with patches that deliver OBP firmware version
4.30.3, 4.30.3.b or 4.30.4 installed (listed below) will not boot if they have a
PCI card with an internal pci-pci bridge installed in certain PCI
slot(s).
2. Contributing Factors
This issue can occur on the following platforms:
SPARC Platform
- Sun Fire V210/V240 Server with OBP firmware 4.30.3.b (as
delivered in patch 142700-01)
- Netra 210/240 Server with OBP firmware 4.30.3.b (as delivered in
patch 142700-01)
- Sun Blade 1500 Workstation (non Silver) with OBP firmware 4.30.3
(as delivered in patch 140686-01)
- Sun Blade 2500 Workstation (non Silver) with OBP firmware 4.30.3
(as delivered in patch 140688-01)
- Sun Blade 1500 Workstation Silver with OBP firmware 4.30.3 (as
delivered in patch 140687-01)
- Sun Blade 2500 Workstation Silver with OBP firmware 4.30.3 (as
delivered in patch 140689-01)
- Sun Fire V250 Server with OBP firmware 4.30.3 (as delivered in
patch 140688-01)
- Sun Fire V125 Server with OBP firmware 4.30.4 (as delivered in
patch 142705-01)
Note 1: This issue only occurs
on systems with the OBP firmware versions mentioned above if they have
a PCI card with an internal pci-pci bridge installed in a certain PCI
slot(s). Please see table below for details:
Platform Name Failing Slot Passing Slot
Sun Fire V210/240/Netra210/240 Server 0 1, 2
Sun Blade 1500 Non-Silver Workstation 4 0, 1, 2, 3
Sun Blade 2500 Non-Silver Workstation 2, 5 0, 1, 3, 4
Sun Blade 1500 Silver Workstation 4 0, 1, 2, 3
Sun Blade 2500 Silver Workstation 2, 5 0, 1, 3, 4
Sun Fire V250 Server 2, 5 0, 1, 3, 4
Sun Fire V125 Server 0 1, 2
Note 2: To determine the
current OBP firmware version installed on a system, the following
command can be used:
$ prtdiag -v | grep OBP
Alternatively, if system is not booted and is sitting at the ok prompt,
do the following:
{0} ok .version
3. Symptoms
If the described issue occurs, the system will display the following
error message on boot:
ERROR: <pci_device_path>/<Unnamed>: Last Trap: Data Access Error
For example, for Sun Fire V240 server, the following message is
displayed:
ERROR: /pci@1d,700000/pci@1/<Unnamed>: Last Trap: Data Access Error
4. Workaround
If the affected patches are installed, downgrade to the previous OBP
version as delivered by the patches listed below:
- Sun Fire V210/V240 Server with OBP firmware 4.22.33 (as delivered
in patch 121683-06)
- Netra 210/240 Server with OBP firmware 4.22.33 (as delivered in
patch 121683-06)
- Sun Blade 1500 Workstation (non Silver) with OBP firmware 4.17.1
(as delivered in patch 119236-01)
- Sun Blade 2500 Workstation (non Silver) with OBP firmware 4.17.1
(as delivered in patch 119232-02)
- Sun Blade 1500 Workstation Silver with OBP firmware 4.17.1 (as
delivered in patch 119237-02)
- Sun Blade 2500 Workstation Silver with OBP firmware 4.17.3 (as
delivered in patch 119233-02)
- Sun Fire V250 Server with OBP firmware 4.17.1 (as delivered in
patch 119232-02)
- Sun Fire V125 Server with OBP firmware 4.22.33 (as delivered in
patch 121691-05)
5. Resolution
This issue is addressed on the following platforms:
SPARC Platform- Sun Fire V210/V240 Server with OBP firmware 4.30.4.a (as delivered in patch 142700-02) or later
- Netra 210/240 Server with OBP firmware 4.30.4.a (as delivered in patch 142700-02) or later
- Sun Blade 1500 Workstation (non Silver) with OBP firmware 4.30.4.a (as delivered in patch 140686-02) or later
- Sun Blade 2500 Workstation (non Silver) with OBP firmware 4.30.4.a (as delivered in patch 140688-2) or later
- Sun Blade 1500 Workstation Silver with OBP firmware 4.30.4.a (as delivered in patch 140687-02) or later
- Sun Blade 2500 Workstation Silver with OBP firmware 4.30.4.a (as delivered in patch 140689-02) or later
- Sun Fire V250 Server with OBP firmware 4.30.4.a (as delivered in patch 140688-02) or later
- Sun Fire V125 Server with OBP firmware 4.30.4.a (as delivered in patch 142705-02) or later
Modification History
0-Feb-2010: Updated Resolution section. Resolved
11-Aug-2010: Corrected for document migration issues, no content modified