![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Sun Alert Sure Solution 1019926.1 : Incorrect Software Setting Prior to Shipping on Certain Sun SPARC M4000/M5000 Servers May Allow Unauthorized Access
PreviouslyPublishedAs 249126 Bug Id <BUG: 15531144> Product Sun SPARC Enterprise M4000 Server Sun SPARC Enterprise M5000 Server Date of Resolved Release 12-Jan-2009 Incorrect software setting prior to shipping on certain Sun SPARC M4000/M5000 servers may allow unauthorized access 1. Impact Due to incorrect software settings prior to shipping on certain Sun SPARC 2. Contributing Factors This issue can occur on the following platforms:
XSCF> showhardconfSerial number breakdown to determine affected weeks: PPMYYWWSSSIn the example above, serial number BCF084604T indicates it is from week 46 of 2008. 3. Symptoms If the described issue occurs, the OBP Banner or Browser User Interface (BUI) may display a non-Sun brand. Another symptom can be seen when typing the keyboard sequence <tab><tab> at the XSCF prompt with the current user in "Normal" mode. This sequence will display a list of all available commands. If the command "enablecodboard" is present in the list, the described issue has been experienced. 4. Workaround There is no workaround for this issue. Please see the Resolution below. 5. Resolution If you believe you have an affected system, a Sun Service Request needs to be opened to correct the manufacturing settings. Typically this issue can be fixed using Shared Shell (see: http://oracle.com/us/support/premier/shared-shell-sun-systems-163755.html). For more information on Security Sun Alerts, see <Document: 1009886.1>. Modification History 19-Jan-2009: Updated Impact section. 13-Jun-2014: Corrected link in Resolution section Internal Contributor/submitter Ken.Kambic@sun.com Internal Eng Responsible Engineer James.Hsieh@Sun.COM Internal Services Knowledge Engineer jeff.folla@sun.com Internal Eng Business Unit Group SSG ES (Enterprise Systems) Internal Comments Please send technical questions to the following email: sunalert-tech-questions@sun.com and CC the following persons: Internal Contributor/Submitter Internal Eng Responsible Engineer Attachments This solution has no attachment |
||||||||||||
|