Solution Type  Problem Resolution Sure

Solution  948658.1 :   OCCAS 4.0 Rejects The Notify Received Before The Subscribe Transaction Has Completed  


Related Items
  • Net-Net 4250
  •  
  • Oracle Communications Converged Application Server
  •  
Related Categories
  • PLA-Support>CGBU>CGBU Application Server Family>Service Delivery Applications>CGBU: SDP
  •  
  • _Old GCS Categories>CGBU>CGBU Service Delivery Family>OCCAS>SIP Compliance
  •  




In this Document
Symptoms
Cause
Solution
References


Applies to:

Oracle Communications Converged Application Server - Version 4.0.0 and later
Net-Net 4250
Information in this document applies to any platform.

Symptoms

As described in the RFC3265 (chapter 3.1.4.4),
"Due to the potential for both out-of-order messages and forking,
the subscriber MUST be prepared to receive NOTIFY messages before the SUBSCRIBE transaction has completed." and this NOTIFY must validate the SUBSCRIBE transaction.

But when OCCAS 4.0 receives the NOTIFY message before the 200 Ok response of the corresponding SUBSCRIBE, it returns a "481 Subscription does not exist", rejecting the NOTIFY.



Cause

The issue is caused by the <>.

Solution

This issue was fixed via <> SmartUpdate Patch LADR, <> SmartUpdate Patch S4W2 and <>  SmartUpdate Patch B7WH. But because SmartUpdate Patch VEZB includes SmartUpdate Patch LADR as well as some additional call state handling and memory leak fixes in addition, we recommend using this patch instead.

Which means that we finally recommend installing the following Smart Update patches to resolve this issue:

------------------------------------------
PATCH REPOSITORY INFORMATION
------------------------------------------
OCCAS Version | Patch ID | Download link
--------------+----------+----------------
4.0 | VEZB | <>
4.0 | S4W2 | <>
4.0 | B7WH | <>


NOTE: Further highly recommended patches can be found in <> - Recommended Patches to Install On OCCAS 4.0 or Products Depending on OCCAS 4.0.





.

References

<BUG:8178044> - [CR383777] WLSS 3.1 - NOTIFY REJECTED IF '200 OK' NOT RECEIVED AFTER SUBSCRIBE
<BUG:8921084> - PATCH REQUEST 4.0 :: NOTIFY REJECTED IF "200 OK" NOT RECEIVED AFTER SUBSCRIBE